{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T15:17:29Z","timestamp":1778685449340,"version":"3.51.4"},"reference-count":57,"publisher":"Acoustical Society of America (ASA)","issue":"2","funder":[{"name":"Research Foundation - Flanders","award":["1S45817N"],"award-info":[{"award-number":["1S45817N"]}]},{"name":"Jointly funded by Cochlear Ltd. and Flanders Innovation & Entrepreneurship","award":["150423"],"award-info":[{"award-number":["150423"]}]},{"DOI":"10.13039\/100010663","name":"H2020 European Research Council","doi-asserted-by":"publisher","award":["637424"],"award-info":[{"award-number":["637424"]}],"id":[{"id":"10.13039\/100010663","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,8,1]]},"abstract":"<jats:p>Cochlear implants (CIs) often replace acoustic temporal fine structure by a fixed-rate pulse train. If the pulse timing is arbitrary (that is, not based on the phase information of the acoustic signal), temporal information is quantized by the pulse period. This temporal quantization is probably imperceptible with current clinical devices. However, it could result in large temporal jitter for strategies that aim to improve bilateral and bimodal CI users' perception of interaural time differences (ITDs), such as envelope enhancement. In an experiment with 16 normal-hearing listeners, it is shown that such jitter could deteriorate ITD perception for temporal quantization that corresponds to the often-used stimulation rate of 900 pulses per second (pps): the just-noticeable difference in ITD with quantization was 177\u2009\u03bcs as compared to 129\u2009\u03bcs without quantization. For smaller quantization step sizes, no significant deterioration of ITD perception was found. In conclusion, the binaural system can only average out the effect of temporal quantization to some extent, such that pulse timing should be well-considered. As this psychophysical procedure was somewhat unconventional, different procedural parameters were compared by simulating a number of commonly used two-down one-up adaptive procedures in Appendix B.<\/jats:p>","DOI":"10.1121\/10.0001759","type":"journal-article","created":{"date-parts":[[2020,8,18]],"date-time":"2020-08-18T13:30:24Z","timestamp":1597757424000},"page":"815-828","update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":4,"title":["Temporal quantization deteriorates the discrimination of interaural time differences"],"prefix":"10.1121","volume":"148","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9015-2686","authenticated-orcid":false,"given":"Benjamin","family":"Dieudonn\u00e9","sequence":"first","affiliation":[{"name":"Experimental Oto-rhino-laryngology, Department of Neurosciences, Katholieke Universiteit (KU) Leuven\u2014University of Leuven , Herestraat 49 bus 721, Leuven, 3000, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4832-099X","authenticated-orcid":false,"given":"Mira","family":"Van Wilderode","sequence":"additional","affiliation":[{"name":"Experimental Oto-rhino-laryngology, Department of Neurosciences, Katholieke Universiteit (KU) Leuven\u2014University of Leuven , Herestraat 49 bus 721, Leuven, 3000, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9734-4261","authenticated-orcid":false,"given":"Tom","family":"Francart","sequence":"additional","affiliation":[{"name":"Experimental Oto-rhino-laryngology, Department of Neurosciences, Katholieke Universiteit (KU) Leuven\u2014University of Leuven , Herestraat 49 bus 721, Leuven, 3000, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"231","published-online":{"date-parts":[[2020,8,18]]},"reference":[{"issue":"4","key":"2023080221575054100_c1","doi-asserted-by":"publisher","first-page":"2338","DOI":"10.1121\/1.4979114","article-title":"Extent of lateralization at large interaural time differences in simulated electric hearing and bilateral cochlear implant users","volume":"141","year":"2017","journal-title":"J. Acoust. Soc. Am."},{"issue":"3","key":"2023080221575054100_c2","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1121\/1.1497620","article-title":"Enhancing sensitivity to interaural delays at high frequencies by using \u2018transposed stimuli","volume":"112","year":"2002","journal-title":"J. Acoust. Soc. Am."},{"issue":"5","key":"2023080221575054100_c3","doi-asserted-by":"publisher","first-page":"2939","DOI":"10.1121\/1.3641400","article-title":"Binaural interference in bilateral cochlear-implant listeners","volume":"130","year":"2011","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080221575054100_c4","volume-title":"Spatial Hearing: The Psychophysics of Human Sound Localization","year":"1997"},{"issue":"1","key":"2023080221575054100_c5","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1121\/1.3436540","article-title":"Temporal weighting of interaural time and level differences in high-rate click trains","volume":"128","year":"2010","journal-title":"J. Acoust. Soc. Am."},{"issue":"5","key":"2023080221575054100_c6","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1097\/AUD.0000000000000044","article-title":"Binaural enhancement for bilateral cochlear implant users","volume":"35","year":"2014","journal-title":"Ear Hear."},{"issue":"5","key":"2023080221575054100_c7","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1097\/MOO.0b013e3282ef3d3e","article-title":"Benefits of bilateral cochlear implantation: A review","volume":"15","year":"2007","journal-title":"Curr. Opin. Otolaryngol. Head Neck Surg."},{"issue":"2-3","key":"2023080221575054100_c8","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1080\/0954898X.2016.1219411","article-title":"Models of the electrically stimulated binaural system: A review","volume":"27","year":"2016","journal-title":"Network: Comput. Neural Syst."},{"key":"2023080221575054100_c9","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.heares.2018.03.007","article-title":"Head shadow enhancement with low-frequency beamforming improves sound localization and speech perception for simulated bimodal listeners","volume":"363","year":"2018","journal-title":"Hear. Res."},{"issue":"3","key":"2023080221575054100_c10","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1097\/AUD.0000000000000660","article-title":"Redundant information is sometimes more beneficial than spatial information to understand speech in noise","volume":"40","year":"2019","journal-title":"Ear Hear."},{"key":"2023080221575054100_c11","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000834","article-title":"Speech understanding with bimodal stimulation is determined by monaural signal to noise ratios: No binaural cue processing involved","year":"2020","journal-title":"Ear Hear."},{"issue":"3","key":"2023080221575054100_c12","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1159\/000444740","article-title":"Sound source localization by normal-hearing listeners, hearing-impaired listeners and cochlear implant listeners","volume":"21","year":"2016","journal-title":"Audiol. Neurotol."},{"issue":"4","key":"2023080221575054100_c13","doi-asserted-by":"publisher","first-page":"1724","DOI":"10.1121\/1.4945588","article-title":"Binaural hearing in children using gaussian enveloped and transposed tones","volume":"139","year":"2016","journal-title":"J. Acoust. Soc. Am."},{"issue":"1","key":"2023080221575054100_c14","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s10162-008-0145-8","article-title":"Sensitivity to interaural time differences with combined cochlear implant and acoustic stimulation","volume":"10","year":"2009","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"4","key":"2023080221575054100_c15","doi-asserted-by":"publisher","first-page":"e199","DOI":"10.1097\/AUD.0000000000000152","article-title":"Effect of channel envelope synchrony on interaural time difference sensitivity in bilateral cochlear implant listeners","volume":"36","year":"2015","journal-title":"Ear Hear."},{"issue":"4","key":"2023080221575054100_c16","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1007\/s10162-014-0457-9","article-title":"Modulation enhancement in the electrical signal improves perception of interaural time differences with bimodal stimulation","volume":"15","year":"2014","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"6","key":"2023080221575054100_c17","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1097\/AUD.0b013e31829d14cb","article-title":"Psychophysics, fitting, and signal processing for combined hearing aid and cochlear implant stimulation","volume":"34","year":"2013","journal-title":"Ear Hear."},{"issue":"2","key":"2023080221575054100_c18","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.jneumeth.2008.04.020","article-title":"APEX 3: A multi-purpose test platform for auditory psychophysical experiments","volume":"172","year":"2008","journal-title":"J. Neurosci. Methods"},{"issue":"1","key":"2023080221575054100_c19","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s10162-004-5024-3","article-title":"Noise susceptibility of cochlear implant users: The role of spectral resolution and smearing","volume":"6","year":"2005","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"4","key":"2023080221575054100_c20","doi-asserted-by":"publisher","first-page":"2476","DOI":"10.1121\/1.426851","article-title":"Enhancing the speech envelope of continuous interleaved sampling processors for cochlear implants","volume":"105","year":"1999","journal-title":"J. Acoust. Soc. Am."},{"issue":"2","key":"2023080221575054100_c21","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1121\/1.3283014","article-title":"Median-plane sound localization as a function of the number of spectral channels using a channel vocoder","volume":"127","year":"2010","journal-title":"J. Acoust. Soc. Am."},{"issue":"4","key":"2023080221575054100_c22","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1177\/1084713806296720","article-title":"MED-EL cochlear implants: State of the art and a glimpse into the future","volume":"10","year":"2006","journal-title":"Trends Amplif."},{"issue":"6","key":"2023080221575054100_c23","doi-asserted-by":"publisher","first-page":"3856","DOI":"10.1121\/1.3585847","article-title":"The influence of different segments of the ongoing envelope on sensitivity to interaural time delays","volume":"129","year":"2011","journal-title":"J. Acoust. Soc. Am."},{"issue":"4","key":"2023080221575054100_c24","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1159\/000078391","article-title":"HiResolution and conventional sound processing in the HiResolution bionic ear: Using appropriate outcome measures to assess speech recognition ability","volume":"9","year":"2004","journal-title":"Audiol. Neurotol."},{"issue":"5","key":"2023080221575054100_c25","doi-asserted-by":"publisher","first-page":"1852","DOI":"10.1121\/1.396521","article-title":"Adaptive staircase techniques in psychoacoustics: A comparison of human data and a mathematical model","volume":"83","year":"1988","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080221575054100_c26","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.heares.2016.09.002","article-title":"Speech onset enhancement improves intelligibility in adverse listening conditions for cochlear implant users","volume":"342","year":"2016","journal-title":"Hear. Res."},{"key":"2023080221575054100_c27","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.heares.2014.10.004","article-title":"Perception and coding of interaural time differences with bilateral cochlear implants","volume":"322","year":"2015","journal-title":"Hear. Res."},{"issue":"2","key":"2023080221575054100_c28","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1073\/pnas.0709199105","article-title":"Binaural jitter improves interaural time-difference sensitivity of cochlear implantees at high pulse rates","volume":"105","year":"2008","journal-title":"Proc. Natl. Acad. Sci. U.S.A."},{"issue":"3","key":"2023080221575054100_c29","doi-asserted-by":"publisher","first-page":"1515","DOI":"10.1121\/1.3613704","article-title":"Effects of envelope shape on interaural envelope delay sensitivity in acoustic and electric hearing","volume":"130","year":"2011","journal-title":"J. Acoust. Soc. Am."},{"issue":"2B","key":"2023080221575054100_c30","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1121\/1.1912375","article-title":"Transformed up-down methods in psychoacoustics","volume":"49","year":"1971","journal-title":"J. Acoust. Soc. Am."},{"issue":"4","key":"2023080221575054100_c31","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1007\/s10162-006-0049-4","article-title":"Binaural unmasking with bilateral cochlear implants","volume":"7","year":"2006","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023080221575054100_c32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/2331216515619331","article-title":"Sensitivity to envelope interaural time differences at high modulation rates","volume":"19","year":"2016","journal-title":"Trends Hear."},{"issue":"2","key":"2023080221575054100_c33","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1121\/1.4960572","article-title":"A method to enhance the use of interaural time differences for cochlear implants in reverberant environments","volume":"140","year":"2016","journal-title":"J. Acoust. Soc. Am."},{"issue":"4","key":"2023080221575054100_c34","doi-asserted-by":"publisher","first-page":"2817","DOI":"10.1121\/1.4965299","article-title":"Evaluation of a method for enhancing interaural level differences at low frequencies","volume":"140","year":"2016","journal-title":"J. Acoust. Soc. Am."},{"issue":"6","key":"2023080221575054100_c35","doi-asserted-by":"publisher","first-page":"1339","DOI":"10.1121\/1.381227","article-title":"Lateralization of complex waveforms: Effects of fine structure, amplitude, and duration","volume":"60","year":"1976","journal-title":"J. Acoust. Soc. Am."},{"issue":"6","key":"2023080221575054100_c36","doi-asserted-by":"publisher","first-page":"e272","DOI":"10.1097\/AUD.0000000000000063","article-title":"Fs4, fs4-p, and fsp: A 4-month crossover study of 3 fine structure sound-coding strategies","volume":"35","year":"2014","journal-title":"Ear Hear."},{"issue":"6","key":"2023080221575054100_c37","doi-asserted-by":"publisher","first-page":"3146","DOI":"10.1121\/1.413804","article-title":"Lateralization of comodulated complex waveforms","volume":"98","year":"1995","journal-title":"J. Acoust. Soc. Am."},{"issue":"3","key":"2023080221575054100_c38","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1121\/1.413379","article-title":"Some considerations on the use of adaptive methods for estimating interaural-delay thresholds","volume":"98","year":"1995","journal-title":"J. Acoust. Soc. Am."},{"issue":"1","key":"2023080221575054100_c39","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1121\/1.1578079","article-title":"Precedence-effect thresholds for a population of untrained listeners as a function of stimulus intensity and interclick interval","volume":"114","year":"2003","journal-title":"J. Acoust. Soc. Am."},{"issue":"3","key":"2023080221575054100_c40","doi-asserted-by":"publisher","first-page":"1698","DOI":"10.1121\/1.1776192","article-title":"Localization ability with bimodal hearing aids and bilateral cochlear implants","volume":"116","year":"2004","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080221575054100_c41","article-title":"Improved sensitivity to interaural time differences with the FAST coding strategy","year":"2010"},{"key":"2023080221575054100_c42","article-title":"Stimulus timing for a stimulating medical device","year":"2014"},{"issue":"1","key":"2023080221575054100_c43","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1007\/s10162-020-00743-6","article-title":"Improving interaural time difference sensitivity using short inter-pulse intervals with amplitude-modulated pulse trains in bilateral cochlear implants","volume":"21","year":"2020","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"5","key":"2023080221575054100_c44","doi-asserted-by":"publisher","first-page":"3092","DOI":"10.1121\/1.3377088","article-title":"Temporal weighting of binaural cues revealed by detection of dynamic interaural differences in high-rate Gabor click trains","volume":"127","year":"2010","journal-title":"J. Acoust. Soc. Am."},{"issue":"2","key":"2023080221575054100_c45","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1121\/1.4812857","article-title":"Temporal weighting functions for interaural time and level differences. III. Temporal weighting for lateral position judgments","volume":"134","year":"2013","journal-title":"J. Acoust. Soc. Am."},{"issue":"3","key":"2023080221575054100_c46","doi-asserted-by":"publisher","first-page":"1428","DOI":"10.1121\/1.5026618","article-title":"Mixed stimulation rates to improve sensitivity of interaural timing differences in bilateral cochlear implant listeners","volume":"143","year":"2018","journal-title":"J. Acoust. Soc. Am."},{"issue":"5","key":"2023080221575054100_c47","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1007\/s10162-011-0275-2","article-title":"Binaural unmasking of multi-channel stimuli in bilateral cochlear implant users","volume":"12","year":"2011","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"4","key":"2023080221575054100_c48","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1159\/000190402","article-title":"Bilateral cochlear implants in children: Binaural unmasking","volume":"14","year":"2009","journal-title":"Audiol. Neurotol."},{"key":"2023080221575054100_c49","article-title":"Peak-derived timing stimulation strategy for a multi-channel cochlear implant","year":"2007"},{"issue":"4","key":"2023080221575054100_c50","doi-asserted-by":"publisher","first-page":"2249","DOI":"10.1121\/1.2875229","article-title":"Binaural speech unmasking and localization in noise with bilateral cochlear implants using envelope and fine-timing based strategies","volume":"123","year":"2008","journal-title":"J. Acoust. Soc. Am."},{"issue":"2","key":"2023080221575054100_c51","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1097\/00003446-200204000-00006","article-title":"Sound-direction identification, interaural time delay discrimination, and speech intelligibility advantages in noise for a bilateral cochlear implant user","volume":"23","year":"2002","journal-title":"Ear Hear."},{"issue":"3","key":"2023080221575054100_c52","doi-asserted-by":"publisher","first-page":"1617","DOI":"10.1121\/1.1539520","article-title":"Speech perception, localization, and lateralization with bilateral cochlear implants","volume":"113","year":"2003","journal-title":"J. Acoust. Soc. Am."},{"issue":"4","key":"2023080221575054100_c53","doi-asserted-by":"publisher","first-page":"205","DOI":"10.3109\/03005369709076795","article-title":"Thirty years of the British Journal of Audiology: Guest editorial. The future of cochlear implants","volume":"31","year":"1997","journal-title":"Br. J. Audiol."},{"key":"2023080221575054100_c54","unstructured":"Wouters, J., and Francart, T. (2016). \u201cInteraural time difference enhancement strategy,\u201d U.S. patent 9,283,376."},{"issue":"2","key":"2023080221575054100_c55","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1109\/MSP.2014.2371671","article-title":"Sound coding in cochlear implants: From electric pulses to hearing","volume":"32","year":"2015","journal-title":"IEEE Signal Process. Mag."},{"key":"2023080221575054100_c56","doi-asserted-by":"publisher","first-page":"2331216519843876","DOI":"10.1177\/2331216519843876","article-title":"Reducing the device delay mismatch can improve sound localization in bimodal cochlear implant\/hearing-aid users","volume":"23","year":"2019","journal-title":"Trends Hear."},{"key":"2023080221575054100_c57","doi-asserted-by":"publisher","first-page":"2331216516665608","DOI":"10.1177\/2331216516665608","article-title":"Perception of interaural phase differences with envelope and fine structure coding strategies in bilateral cochlear implant users","volume":"20","year":"2016","journal-title":"Trends Hear."}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/148\/2\/815\/15346012\/815_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/148\/2\/815\/15346012\/815_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,2]],"date-time":"2023-08-02T21:58:06Z","timestamp":1691013486000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/148\/2\/815\/959118\/Temporal-quantization-deteriorates-the"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,1]]},"references-count":57,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,8,1]]}},"URL":"https:\/\/doi.org\/10.1121\/10.0001759","relation":{},"ISSN":["0001-4966","1520-8524"],"issn-type":[{"value":"0001-4966","type":"print"},{"value":"1520-8524","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,8]]},"published":{"date-parts":[[2020,8,1]]}}}