{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T16:43:38Z","timestamp":1770741818471,"version":"3.49.0"},"reference-count":13,"publisher":"Acoustical Society of America (ASA)","issue":"12","license":[{"start":{"date-parts":[[2021,12,16]],"date-time":"2021-12-16T00:00:00Z","timestamp":1639612800000},"content-version":"vor","delay-in-days":15,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,12,16]],"date-time":"2021-12-16T00:00:00Z","timestamp":1639612800000},"content-version":"tdm","delay-in-days":15,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,12,1]]},"abstract":"<jats:p>ADHEAR is a bone conduction hearing aid that uses an adhesive skin adapter. In the current study, the use of ADHEAR as an audiometric bone stimulator was investigated in normal-hearing subjects by comparing it to the standard Radio-Ear B71. Bone conduction thresholds of 15 normal-hearing subjects (aged 21\u201336\u2009years) were measured four times in a randomized order, twice with the B71 and twice with the ADHEAR. There were no significant differences in test-retest reliability between the two devices. Subjectively rated comfort was better for the ADHEAR. The development of a specific audiometric adhesive bone stimulator may be warranted.<\/jats:p>","DOI":"10.1121\/10.0009082","type":"journal-article","created":{"date-parts":[[2021,12,16]],"date-time":"2021-12-16T16:34:22Z","timestamp":1639672462000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":2,"title":["ADHEAR device in bone conduction audiometry"],"prefix":"10.1121","volume":"1","author":[{"given":"Flurin","family":"Pfiffner","sequence":"first","affiliation":[{"name":"Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich , Zurich, CH-8091, Switzerland \u2008 flurin.pfiffner@usz.ch , andrea.kegel@usz.ch , rudolfr.probst@uzh.ch"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Kegel","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich , Zurich, CH-8091, Switzerland \u2008 flurin.pfiffner@usz.ch , andrea.kegel@usz.ch , rudolfr.probst@uzh.ch"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rudolf","family":"Probst","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich , Zurich, CH-8091, Switzerland \u2008 flurin.pfiffner@usz.ch , andrea.kegel@usz.ch , rudolfr.probst@uzh.ch"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"231","published-online":{"date-parts":[[2021,12,16]]},"reference":[{"key":"2023062619093098800_c1","doi-asserted-by":"publisher","first-page":"798","DOI":"10.1001\/archotol.1950.00700020824003","article-title":"Clinical application of bone conduction audiometry","volume":"51","year":"1950","journal-title":"Arch. Otolaryngol."},{"key":"2023062619093098800_c2","doi-asserted-by":"publisher","first-page":"233121651983605","DOI":"10.1177\/2331216519836053","article-title":"Characteristics of Bone-Conduction Devices Simulated in a Finite-Element Model of a Whole Human Head","volume":"23","year":"2019","journal-title":"Trends Hear."},{"key":"2023062619093098800_c3","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1097\/MAO.0000000000002184","article-title":"A randomized cross-over trial comparing a pressure-free, adhesive to a conventional bone conduction hearing device","volume":"40","year":"2019","journal-title":"Otol. Neurotol."},{"key":"2023062619093098800_c4","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1097\/MAO.0000000000001829","article-title":"First results with a new, pressure-free, adhesive bone conduction hearing aid","volume":"39","year":"2018","journal-title":"Otol. Neurotol."},{"key":"2023062619093098800_c5","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1055\/a-1308-3888","article-title":"Experimental evaluation of the adhear, a novel transcutaneous bone conduction hearing aid","volume":"100","year":"2021","journal-title":"Laryngorhinootologie"},{"key":"2023062619093098800_c6","doi-asserted-by":"publisher","first-page":"439","DOI":"10.3109\/14992027.2016.1172120","article-title":"Influence of stimulation position on the sensitivity for bone conduction hearing aids without skin penetration","volume":"55","year":"2016","journal-title":"Int. J. Audiol."},{"key":"2023062619093098800_c7","doi-asserted-by":"publisher","first-page":"207","DOI":"10.3390\/audiolres11020019","article-title":"Review of bone conduction hearing devices","volume":"11","year":"2021","journal-title":"Audiol. Res."},{"key":"2023062619093098800_c8","doi-asserted-by":"publisher","first-page":"e0195233","DOI":"10.1371\/journal.pone.0195233","article-title":"Influence of transducer types on bone conduction hearing thresholds","volume":"13","year":"2018","journal-title":"PLoS One"},{"key":"2023062619093098800_c9","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1097\/MAO.0000000000001924","article-title":"Unilateral and bilateral audiological benefit with an adhesively attached, noninvasive bone conduction hearing system","volume":"39","year":"2018","journal-title":"Otol. Neurotol."},{"key":"2023062619093098800_c10","volume-title":"Acoustics\u2014Audiometric Test Methods\u2014Part 1: Pure-Tone Air and Bone Conduction Audiometry","author":"ISO","year":"2010"},{"key":"2023062619093098800_c11","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1097\/MAO.0000000000002657","article-title":"The Use of a novel, nonsurgical bone conduction hearing aid system for the treatment of conductive hearing loss","volume":"41","year":"2020","journal-title":"Otol. Neurotol."},{"key":"2023062619093098800_c12","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1159\/000323585","article-title":"Audiological Results with Baha\u00ae in Conductive and Mixed Hearing Loss","volume":"71","year":"2011","journal-title":"Adv. Otorhino. Laryng."},{"key":"2023062619093098800_c13","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1044\/jshr.0504.321","article-title":"Placement of vibrator in bone-conduction testing","volume":"5","year":"1962","journal-title":"J. Speech Hear. Res."}],"container-title":["JASA Express Letters"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jel\/article-pdf\/doi\/10.1121\/10.0009082\/13587393\/122001_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/pubs.aip.org\/asa\/jel\/article-pdf\/doi\/10.1121\/10.0009082\/13587393\/122001_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jel\/article-pdf\/doi\/10.1121\/10.0009082\/13587393\/122001_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T14:33:43Z","timestamp":1746801223000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jel\/article\/1\/12\/122001\/219481\/ADHEAR-device-in-bone-conduction-audiometry"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,1]]},"references-count":13,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12,1]]}},"URL":"https:\/\/doi.org\/10.1121\/10.0009082","relation":{},"ISSN":["2691-1191"],"issn-type":[{"value":"2691-1191","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,12]]},"published":{"date-parts":[[2021,12,1]]},"article-number":"122001"}}