{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T00:35:23Z","timestamp":1791592523030,"version":"4.3.4"},"reference-count":31,"publisher":"Acoustical Society of America (ASA)","issue":"3","funder":[{"DOI":"10.13039\/100007048","name":"Mayo Foundation for Medical Education and Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007048","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007048","name":"Mayo Foundation for Medical Education and Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007048","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,3,1]]},"abstract":"<jats:p>Standard clinical protocols require hearing protection during magnetic resonance imaging (MRI) for patient safety. This investigation prospectively evaluated the auditory function impact of acoustic noise exposure during a 3.0T MRI in healthy adults. Twenty-nine participants with normal hearing underwent a comprehensive audiologic assessment before and immediately following a clinically indicated head MRI. Appropriate hearing protection with earplugs (and pads) was used per standard of practice. To characterize noise hazards, current sound monitoring tools were used to measure levels of pulse sequences measured. A third audiologic test was performed if a significant threshold shift (STS) was identified at the second test, within 30\u2009days post MRI. Some sequences produced high levels (up to 114.5\u2009dBA; 129\u2009dB peak SPL) that required hearing protection but did not exceed 100% daily noise dose. One participant exhibited an STS in the frequency region most highly associated with noise-induced hearing loss. No participants experienced OSHA-defined STS in either ear. Overall, OAE measures did not show evidence of changes in cochlear function after MRI. In conclusion, hearing threshold shifts associated with hearing loss or OAE level shifts reflecting underlying cochlear damage were not detected in any of the 3.0T MRI study participants who used the current recommended hearing protection.<\/jats:p>","DOI":"10.1121\/10.0009824","type":"journal-article","created":{"date-parts":[[2022,3,21]],"date-time":"2022-03-21T12:27:20Z","timestamp":1647865640000},"page":"1913-1921","update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation of hearing loss in young adults after exposure to 3.0T MRI with standard hearing protection"],"prefix":"10.1121","volume":"151","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4585-2958","authenticated-orcid":false,"given":"Carrie M","family":"Carr","sequence":"first","affiliation":[{"name":"Division of Neuroradiology, Department of Radiology, Mayo Clinic 1 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7803-9293","authenticated-orcid":false,"given":"John I","family":"Lane","sequence":"additional","affiliation":[{"name":"Division of Neuroradiology, Department of Radiology, Mayo Clinic 1 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Larry J","family":"Eckel","sequence":"additional","affiliation":[{"name":"Division of Neuroradiology, Department of Radiology, Mayo Clinic 1 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9458-8017","authenticated-orcid":false,"given":"Felix E","family":"Diehn","sequence":"additional","affiliation":[{"name":"Division of Neuroradiology, Department of Radiology, Mayo Clinic 1 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dave F","family":"Kallmes","sequence":"additional","affiliation":[{"name":"Division of Neuroradiology, Department of Radiology, Mayo Clinic 1 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew L","family":"Carlson","sequence":"additional","affiliation":[{"name":"Division of Audiology, Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic 2 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7521-9088","authenticated-orcid":false,"given":"Yunhong","family":"Shu","sequence":"additional","affiliation":[{"name":"Division of Medical Physics, Department of Radiology, Mayo Clinic 3 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matt A","family":"Bernstein","sequence":"additional","affiliation":[{"name":"Division of Medical Physics, Department of Radiology, Mayo Clinic 3 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1678-8774","authenticated-orcid":false,"given":"Tina M","family":"Gunderson","sequence":"additional","affiliation":[{"name":"Department of Biomedical Statistics and Informatics, Mayo Clinic 4 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4132-4461","authenticated-orcid":false,"given":"Gayla L","family":"Poling","sequence":"additional","affiliation":[{"name":"Division of Audiology, Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic 2 , 200 First Street Southwest, Rochester, Minnesota 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"231","published-online":{"date-parts":[[2022,3,21]]},"reference":[{"key":"2023080317362049500_c2","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1002\/jmri.24011","article-title":"ACR guidance document on MR safe practices","volume":"37","author":"ACR","year":"2013","journal-title":"JMRI"},{"key":"2023080317362049500_c3","unstructured":"ACR (2021). \u201c\nLarge and medium phantom test guidance,\u201d ACR Accreditation, pp. 1\u201339, https:\/\/www.acraccreditation.org\/modalities\/mri (Last viewed March 14, 2022)."},{"key":"2023080317362049500_c1","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1093\/occmed\/51.4.245","article-title":"High-frequency (10\u201318 kHz) hearing thresholds: Reliability, and effects of age and occupational noise exposure","volume":"51","year":"2001","journal-title":"Occup. Med. (London)"},{"key":"2023080317362049500_c4","volume-title":"Specifications for Audiometers","author":"ANSI","year":"2004"},{"key":"2023080317362049500_c5","volume-title":"Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms","author":"ANSI","year":"2013"},{"key":"2023080317362049500_c6","unstructured":"ASHA (1994). \u201c\nAudiologic management of individuals receiving cochleotoxic drug therapy,\u201d American Speech-Language-Hearing Association, https:\/\/www.asha.org\/policy\/gl1994-00003\/ (Last viewed March 14, 2022)."},{"key":"2023080317362049500_c7","unstructured":"ASHA (2005). \u201c\nGuidelines for Manual Pure-Tone Threshold Audiometry,\u201d American Speech-Language-Hearing Association, https:\/\/www.asha.org\/policy\/gl2005-00014\/ (Last viewed March 14, 2022)."},{"key":"2023080317362049500_c8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/8756579","article-title":"Hearing thresholds changes after MRI 1.5T of head and neck","volume":"2019","year":"2019","journal-title":"Radiol. Res. Pract."},{"key":"2023080317362049500_c9","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.disamonth.2013.01.005","article-title":"Clinical measures of auditory function: The cochlea and beyond","volume":"59","year":"2013","journal-title":"Dis. Mon."},{"key":"2023080317362049500_c10","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1148\/radiology.169.2.3175004","article-title":"Potential hearing loss resulting from MR imaging","volume":"169","year":"1988","journal-title":"Radiology"},{"key":"2023080317362049500_c11","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1044\/jshd.2404.330","article-title":"Preferred method for clinical determination of pure-tone thresholds","volume":"24","year":"1959","journal-title":"J. Speech Hear. Disord."},{"key":"2023080317362049500_c12","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1016\/j.anl.2010.12.006","article-title":"Hearing loss after noise exposure","volume":"38","year":"2011","journal-title":"Auris Nasus Larynx"},{"key":"2023080317362049500_c13","first-page":"71","article-title":"Pure tone evaluation","volume-title":"Handbook of Clinical Audiology","author":"Katz","year":"2002"},{"key":"2023080317362049500_c14","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.disamonth.2013.01.002","article-title":"Understanding and preventing noise-induced hearing loss","volume":"59","year":"2013","journal-title":"Dis. Mon."},{"key":"2023080317362049500_c15","volume-title":"Medical Electrical Equipment\u2014Part 2-33: Particular Requirements for the Basic Safety and Essential Performance of Magnetic Resonance Equipment for Medical Diagnosis","author":"IEC","year":"2010"},{"key":"2023080317362049500_c16","volume-title":"Noise and Military Service: Implications for Hearing Loss and Tinnitus","author":"Institute of Medicine","year":"2005"},{"key":"2023080317362049500_c17","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1148\/radiol.2017161622","article-title":"Temporary hearing threshold shift in healthy volunteers with hearing protection caused by acoustic noise exposure during 3-T multisequence MR neuroimaging","volume":"286","year":"2018","journal-title":"Radiology"},{"key":"2023080317362049500_c18","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1121\/1.382104","article-title":"Stimulated acoustic emissions from within the human auditory system","volume":"64","year":"1978","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080317362049500_c19","doi-asserted-by":"publisher","first-page":"e286","DOI":"10.1097\/MAO.0000000000001134","article-title":"Serial monitoring of otoacoustic emissions in clinical trials","volume":"37","year":"2016","journal-title":"Otol. Neurotol."},{"key":"2023080317362049500_c20","doi-asserted-by":"publisher","first-page":"14077","DOI":"10.1523\/JNEUROSCI.2845-09.2009","article-title":"Adding insult to injury: Cochlear nerve degeneration after \u2018temporary\u2019 noise-induced hearing loss","volume":"29","year":"2009","journal-title":"J. Neurosci."},{"key":"2023080317362049500_c21","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1097\/AUD.0b013e31823d7917","article-title":"Behavioral hearing thresholds between 0.125 and 20 kHz using depth-compensated ear simulator calibration","volume":"33","year":"2012","journal-title":"Ear Hear."},{"key":"2023080317362049500_c22","doi-asserted-by":"publisher","first-page":"3109","DOI":"10.1007\/s00405-014-3232-y","article-title":"3 Tesla magnetic resonance imaging noise in standard head and neck sequence does not cause temporary threshold shift in high frequency","volume":"272","year":"2015","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"2023080317362049500_c23","first-page":"43","article-title":"Distortion-product otoacoustic emissions as a screening tool for noise-induced hearing loss","volume":"3","year":"2001","journal-title":"Noise Health"},{"key":"2023080317362049500_c24","first-page":"9738","volume-title":"Occupational Noise Exposure: Hearing Conservation Amendments Final Rule","author":"OSHA","year":"1983"},{"key":"2023080317362049500_c25","doi-asserted-by":"publisher","first-page":"73","DOI":"10.3109\/01050397909076304","article-title":"High-frequency audiometry: Age and sex variations","volume":"8","year":"1979","journal-title":"Scand. Audiol."},{"key":"2023080317362049500_c26","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1121\/1.4845415","article-title":"Characteristics of the 2f(1)-f(2) distortion product otoacoustic emission in a normal hearing population","volume":"135","year":"2014","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080317362049500_c27","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1002\/1522-2586(200102)13:2&lt;288::AID-JMRI1041&gt;3.0.CO;2-P","article-title":"Investigation of acoustic noise on 15 MRI scanners from 0.2 T to 3 T","volume":"13","year":"2001","journal-title":"J. Magn. Reason. Imag."},{"key":"2023080317362049500_c28","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.1016\/S0140-6736(02)08423-4","article-title":"Effect of MRI noise on cochlear function","volume":"359","year":"2002","journal-title":"Lancet"},{"key":"2023080317362049500_c29","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1007\/s00261-016-0680-4","article-title":"Magnetic resonance safety","volume":"41","year":"2016","journal-title":"Abdom. Radiol."},{"key":"2023080317362049500_c30","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1097\/01.AUD.0000120361.87401.C8","article-title":"Test-retest reliability of pure-tone thresholds from 0.5 to 16\u2009kHz using Sennheiser HDA 200 and Etymotic Research ER-2 earphones","volume":"25","year":"2004","journal-title":"Ear Hear."},{"key":"2023080317362049500_c31","doi-asserted-by":"publisher","first-page":"2024","DOI":"10.1002\/mrm.26863","article-title":"Magnetization-prepared shells trajectory with automated gradient waveform design","volume":"79","year":"2018","journal-title":"Magn. Reason. Med."}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/151\/3\/1913\/18073564\/1913_1_10.0009824.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/151\/3\/1913\/18073564\/1913_1_10.0009824.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,3]],"date-time":"2023-08-03T17:36:45Z","timestamp":1691084205000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/151\/3\/1913\/2838294\/Evaluation-of-hearing-loss-in-young-adults-after"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,1]]},"references-count":31,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,3,1]]}},"URL":"https:\/\/doi.org\/10.1121\/10.0009824","relation":{},"ISSN":["0001-4966"],"issn-type":[{"value":"0001-4966","type":"print"}],"subject":[],"published-other":{"date-parts":[[2022,3]]},"published":{"date-parts":[[2022,3,1]]}}}