{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T11:43:09Z","timestamp":1792755789452,"version":"4.5.0"},"reference-count":36,"publisher":"Acoustical Society of America (ASA)","issue":"6","license":[{"start":{"date-parts":[[2023,6,26]],"date-time":"2023-06-26T00:00:00Z","timestamp":1687737600000},"content-version":"vor","delay-in-days":25,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,6,26]],"date-time":"2023-06-26T00:00:00Z","timestamp":1687737600000},"content-version":"tdm","delay-in-days":25,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000055","name":"National Institute on Deafness and Other Communication Disorders","doi-asserted-by":"publisher","award":["R01 DC015809"],"award-info":[{"award-number":["R01 DC015809"]}],"id":[{"id":"10.13039\/100000055","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,6,1]]},"abstract":"<jats:p>The electrically evoked compound action potentials (ECAPs) amplitude-growth function (AGF) slope correlates with spiral ganglion neuron (SGN) density in the cochlear implanted cochlea. Electrode insertion angle and medial\u2013lateral distance covary from base to apex; in some human ears, SGN survival varies from base to apex, making it difficult to parse out contributing factors to the ECAP AGF slope. Evoked compound action potentials were analyzed on each electrode and compared to post-operative computerized tomography scans. When controlling for medial\u2013lateral distance, insertion angle does not influence ECAP AGF slope.<\/jats:p>","DOI":"10.1121\/10.0019806","type":"journal-article","created":{"date-parts":[[2023,6,26]],"date-time":"2023-06-26T15:26:47Z","timestamp":1687793207000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":6,"title":["Reexamining the effects of electrode location on measures of neural health in cochlear implant users"],"prefix":"10.1121","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8194-6513","authenticated-orcid":false,"given":"Kara C.","family":"Schvartz-Leyzac","sequence":"first","affiliation":[{"name":"Medical University of South Carolina, Department of Otolaryngology-Head & Neck Surgery 1 , 135 Rutledge Avenue, Charleston, South Carolina 29425, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryan E.","family":"Pfingst","sequence":"additional","affiliation":[{"name":"University of Michigan, Kresge Hearing Research Institute, Department of Otolaryngology- Head & Neck Surgery 2 , 4605 Medical Science Unit II, Ann Arbor, Michigan 48109, USA leyzac@musc.edu , bpfingst@umich.edu"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"231","published-online":{"date-parts":[[2023,6,26]]},"reference":[{"key":"2023062612451657600_c1","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1097\/00003446-199902000-00005","article-title":"Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential","volume":"20","year":"1999","journal-title":"Ear Hear."},{"key":"2023062612451657600_c2","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1159\/000078390","article-title":"Channel interaction in cochlear implant users evaluated using the electrically evoked compound action potential","volume":"9","year":"2004","journal-title":"Audiol. Neurotol."},{"key":"2023062612451657600_c3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.18637\/jss.v067.i01","article-title":"Fitting linear mixed-effects models using lme4","volume":"67","year":"2015","journal-title":"J. Stat. Softw."},{"key":"2023062612451657600_c4","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/1475-925X-8-40","article-title":"Site of cochlear stimulation and its effect on electrically evoked compound action potentials using the MED-EL standard electrode array","volume":"8","year":"2009","journal-title":"BioMed. Eng. OnLine"},{"key":"2023062612451657600_c5","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1007\/s10162-016-0557-9","article-title":"Assessing the electrode-neuron interface with the electrically evoked compound action potential, electrode position, and behavioral thresholds","volume":"17","year":"2016","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023062612451657600_c6","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1097\/MAO.0b013e318184f492","article-title":"Role of electrode placement as a contributor to variability in cochlear implant outcomes","volume":"29","year":"2008","journal-title":"Otol. Neurotol."},{"key":"2023062612451657600_c7","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1111\/j.1749-6632.1983.tb31662.x","article-title":"Histopathology of profound sensorineural deafness","volume":"405","year":"1983","journal-title":"Ann. N.Y. Acad. Sci."},{"key":"2023062612451657600_c8","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.heares.2016.06.015","article-title":"Correlation between word recognition score and intracochlear new bone and fibrous tissue after cochlear implantation in the human","volume":"339","year":"2016","journal-title":"Hear. Res."},{"key":"2023062612451657600_c9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.18637\/jss.v082.i13","article-title":"lmerTest Package: Tests in linear mixed effects models","volume":"82","year":"2017","journal-title":"J. Stat. Softw."},{"key":"2023062612451657600_c10","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1007\/s10162-013-0437-5","article-title":"Examining the electro-neural interface of cochlear implant users using psychophysics, CT scans, and speech understanding","volume":"15","year":"2014","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023062612451657600_c11","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/S0194-5998(97)70178-5","article-title":"Patterns of neural degeneration in the human cochlea and auditory nerve: Implications for cochlear implantation","volume":"117","year":"1997","journal-title":"Otolaryngol. Head Neck Surg."},{"key":"2023062612451657600_c12","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1159\/000365273","article-title":"Clinical evaluation of an image-guided cochlear implant programming strategy","volume":"19","year":"2014","journal-title":"Audiol. Neurotol."},{"key":"2023062612451657600_c13","doi-asserted-by":"publisher","first-page":"e63","DOI":"10.1097\/MAO.0000000000000909","article-title":"Initial results with image-guided cochlear implant programming in children","volume":"37","year":"2016","journal-title":"Otol. Neurotol."},{"key":"2023062612451657600_c14","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1109\/TNSRE.2013.2253333","article-title":"Image-guidance enables new methods for customizing cochlear implant stimulation strategies","volume":"21","year":"2013","journal-title":"IEEE Trans. Neural Syst. Rehabilitation Eng."},{"key":"2023062612451657600_c15","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1097\/MAO.0000000000001125","article-title":"Electrode location and angular insertion depth are predictors of audiologic outcomes in cochlear implantation","volume":"37","year":"2016","journal-title":"Otol. Neurotol."},{"key":"2023062612451657600_c16","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1002\/lio2.42","article-title":"The importance of electrode location in cochlear implantation","volume":"1","year":"2016","journal-title":"Laryngoscope Investig. Otolaryngol."},{"key":"2023062612451657600_c17","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1007\/s10162-017-0633-9","article-title":"Neurotrophin gene therapy in deafened ears with cochlear implants: Long-term effects on nerve survival and functional measures","volume":"18","year":"2017","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023062612451657600_c18","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.heares.2006.03.006","article-title":"Effect of interphase gap and pulse duration on electrically evoked potentials is correlated with auditory nerve survival","volume":"215","year":"2006","journal-title":"Hear. Res."},{"key":"2023062612451657600_c19","volume-title":"R: A Language and Environment for Statistical Computing","author":"R-CoreTeam","year":"2020"},{"key":"2023062612451657600_c20","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.heares.2015.01.001","article-title":"Recovery characteristics of the electrically stimulated auditory nerve in deafened guinea pigs: Relation to neuronal status","volume":"321","year":"2015","journal-title":"Hear. Res."},{"key":"2023062612451657600_c21","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1007\/s10162-013-0440-x","article-title":"Auditory-nerve responses to varied inter-phase gap and phase duration of the electric pulse stimulus as predictors for neuronal degeneration","volume":"15","year":"2014","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023062612451657600_c22","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.joto.2017.01.001","article-title":"Suprathreshold compound action potential amplitude as a measure of auditory function in cochlear implant users","volume":"12","year":"2017","journal-title":"J. Otol."},{"key":"2023062612451657600_c23","doi-asserted-by":"publisher","first-page":"3900","DOI":"10.1121\/10.0002882","article-title":"How electrically evoked compound action potentials in chronically implanted guinea pigs relate to auditory nerve health and electrode impedance","volume":"148","year":"2020","journal-title":"J. Acoust. Soc. Am."},{"key":"2023062612451657600_c24","doi-asserted-by":"crossref","first-page":"107809","DOI":"10.1016\/j.heares.2019.107809","article-title":"Changes over time in the electrically evoked compound action potential (ECAP) interphase gap (IPG) effect following cochlear implantation in Guinea pigs","volume":"383","year":"2019","journal-title":"Hear. Res."},{"key":"2023062612451657600_c25","first-page":"324","article-title":"Effects of electrode location on estimates of neural health in humans with cochlear implants","volume":"18","year":"2020","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023062612451657600_c26","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.heares.2016.08.002","article-title":"Across-site patterns of electrically evoked compound action potential amplitude-growth functions in multichannel cochlear implant recipients and the effects of the interphase gap","volume":"341","year":"2016","journal-title":"Hear. Res."},{"key":"2023062612451657600_c27","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1097\/AUD.0000000000000490","article-title":"Assessing the relationship between the electrically evoked compound action potential and speech recognition abilities in bilateral cochlear implant recipients","volume":"39","year":"2018","journal-title":"Ear Hear."},{"key":"2023062612451657600_c28","doi-asserted-by":"publisher","first-page":"108257","DOI":"10.1016\/j.heares.2021.108257","article-title":"Using the electrically-evoked compound action potential (ECAP) interphase gap effect to select electrode stimulation sites in cochlear implant users","volume":"406","year":"2021","journal-title":"Hear. Res."},{"key":"2023062612451657600_c29","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/0378-5955(93)90265-3","article-title":"Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation","volume":"66","year":"1993","journal-title":"Hear. Res."},{"key":"2023062612451657600_c30","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1097\/AUD.0000000000001084","article-title":"A broadly applicable method for characterizing the slope of the electrically evoked compound action potential amplitude growth function","volume":"43","year":"2022","journal-title":"Ear Hear."},{"key":"2023062612451657600_c31","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1177\/00034894071160S401","article-title":"In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea","volume":"116","year":"2007","journal-title":"Ann. Otol. Rhinol. Laryngol."},{"key":"2023062612451657600_c32","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1097\/MAO.0b013e3182255915","article-title":"Verification of computed tomographic estimates of cochlear implant array position: A micro-CT and histologic analysis","volume":"32","year":"2011","journal-title":"Otol. Neurotol."},{"key":"2023062612451657600_c33","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1080\/14670100.2016.1240427","article-title":"Electrically evoked compound action potentials are different depending on the site of cochlear stimulation","volume":"17","year":"2016","journal-title":"Cochlear Implants Int."},{"key":"2023062612451657600_c34","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1002\/lary.26154","article-title":"Systematic review of compound action potentials as predictors for cochlear implant performance","volume":"127","year":"2017","journal-title":"Laryngoscope"},{"key":"2023062612451657600_c35","first-page":"S1","article-title":"Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes","volume":"124","year":"2014","journal-title":"Laryngoscope"},{"key":"2023062612451657600_c36","doi-asserted-by":"publisher","first-page":"021202","DOI":"10.1117\/1.JMI.5.2.021202","article-title":"Selecting electrode configurations for image-guided cochlear implant programming using template matching","volume":"5","year":"2018","journal-title":"J. Med. Imaging (Bellingham)"}],"container-title":["JASA Express Letters"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jel\/article-pdf\/doi\/10.1121\/10.0019806\/18018041\/065201_1_10.0019806.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/pubs.aip.org\/asa\/jel\/article-pdf\/doi\/10.1121\/10.0019806\/18018041\/065201_1_10.0019806.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jel\/article-pdf\/doi\/10.1121\/10.0019806\/18018041\/065201_1_10.0019806.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T14:33:46Z","timestamp":1746801226000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jel\/article\/3\/6\/065201\/2900251\/Reexamining-the-effects-of-electrode-location-on"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,1]]},"references-count":36,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023,6,1]]}},"URL":"https:\/\/doi.org\/10.1121\/10.0019806","relation":{},"ISSN":["2691-1191"],"issn-type":[{"value":"2691-1191","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,6]]},"published":{"date-parts":[[2023,6,1]]},"article-number":"065201"}}