{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:19:55Z","timestamp":1788970795196,"version":"build-2803163510"},"reference-count":43,"publisher":"Acoustical Society of America (ASA)","issue":"3","funder":[{"DOI":"10.13039\/501100018857","name":"MED-EL","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100018857","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,9,1]]},"abstract":"<jats:p>Cochlear implant users do not experience spatial hearing with the same accuracy or acuity as typical hearing listeners. Two standard measures of spatial hearing are sound localization error and speech reception thresholds (SRTs) in spatially separated noise. While sound localization requires a complicated setup, SRTs may be measured with fewer loudspeakers and less testing time. If a predictive relationship between sound localization error and SRTs can be measured, then the spatial hearing abilities of cochlear implant users may be quickly assessed by measuring one task or the other. To test this, 12 bilateral, ten single-sided deaf, six bimodal, and five unilaterally implanted listeners were recruited. In general, bilateral users had the smallest localization error and greatest improvement in SRTs between collocated and spatially separated conditions, while unilateral users had the largest localization error and worst SRTs. When unilateral listeners were excluded, localization error was significantly correlated with the difference between spatially separated and collocated SRTs. There was no relationship between sound localization error and raw SRT scores. The spatial hearing of unilateral listeners would benefit from receiving a second implant, and many bimodal users would likely experience a benefit from this intervention as well.<\/jats:p>","DOI":"10.1121\/10.0046392","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:05:25Z","timestamp":1788969925000},"page":"2067-2077","update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":0,"title":["Comparing sound localization and speech-in-noise in unilateral, bilateral, single-sided deaf, and bimodal cochlear implant users"],"prefix":"10.1121","volume":"160","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7667-9422","authenticated-orcid":false,"given":"Stephen R.","family":"Dennison","sequence":"first","affiliation":[{"name":"North American Research Lab, MED-EL US , Durham, North Carolina 27713,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3069-7075","authenticated-orcid":false,"given":"Jenna","family":"Felder","sequence":"additional","affiliation":[{"name":"North American Research Lab, MED-EL US , Durham, North Carolina 27713,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-5475-0354","authenticated-orcid":false,"given":"Caroline K.","family":"Paroby","sequence":"additional","affiliation":[{"name":"North American Research Lab, MED-EL US , Durham, North Carolina 27713,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2547-6972","authenticated-orcid":false,"given":"Joshua S.","family":"Stohl","sequence":"additional","affiliation":[{"name":"North American Research Lab, MED-EL US , Durham, North Carolina 27713,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"231","published-online":{"date-parts":[[2026,9,9]]},"reference":[{"issue":"5","key":"2026090911202384600_c1","doi-asserted-by":"publisher","first-page":"1725","DOI":"10.1002\/ohn.1187","article-title":"Comparing bilateral and single-sided deaf cochlear implant recipients in a novel speech-in-noise and localization task","volume":"172","year":"2025","journal-title":"Otolaryngol. Head Neck Surg."},{"issue":"5","key":"2026090911202384600_c2","doi-asserted-by":"publisher","first-page":"3232","DOI":"10.1121\/1.5130384","article-title":"Effects of rate and age in processing interaural time and level differences in normal-hearing and bilateral cochlear-implant listeners","volume":"146","year":"2019","journal-title":"J. Acoust. Soc. Am."},{"key":"2026090911202384600_c3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/23312165211016165","article-title":"Sound localization bias and error in bimodal listeners improve instantaneously when the device delay mismatch is reduced","volume":"25","year":"2021","journal-title":"Trends Hear."},{"key":"2026090911202384600_c4","volume-title":"On the Definition of Hearing Handicap","author":"American Speech-Language-Hearing Association","year":"1981"},{"key":"2026090911202384600_c5","volume-title":"Spatial Hearing: The Psychophysics of Human Sound Localization","year":"1996"},{"issue":"6","key":"2026090911202384600_c6","doi-asserted-by":"publisher","first-page":"2801","DOI":"10.1121\/1.1479152","article-title":"Efficient adaptive procedures for threshold and concurrent slope estimates for psychophysics and speech intelligibility tests","volume":"111","year":"2002","journal-title":"J. Acoust. Soc. Am."},{"issue":"1","key":"2026090911202384600_c7","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1097\/AUD.0b013e31815d7467","article-title":"Multicenter US bilateral MED-EL cochlear implantation study: Speech perception over the first year of use","volume":"29","year":"2008","journal-title":"Ear Hear."},{"key":"2026090911202384600_c8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/23312165251340864","article-title":"Estimating cochlear implant users' sound localization abilities with two loudspeakers","volume":"29","year":"2025","journal-title":"Trends Hear."},{"issue":"4","key":"2026090911202384600_c9","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.1097\/AUD.0000000000001179","article-title":"The impact of synchronized cochlear implant sampling and stimulation on free-field spatial hearing outcomes: Comparing the ciPDA research processor to clinical processors","volume":"43","year":"2022","journal-title":"Ear Hear."},{"issue":"3","key":"2026090911202384600_c10","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1097\/AUD.0000000000000660","article-title":"Redundant information is sometimes more beneficial than spatial information to understand speech in noise","volume":"40","year":"2019","journal-title":"Ear Hear."},{"issue":"6","key":"2026090911202384600_c11","doi-asserted-by":"publisher","first-page":"1605","DOI":"10.1097\/AUD.0000000000001260","article-title":"American Cochlear Implant Alliance Task Force guidelines for clinical assessment and management of adult cochlear implantation for single-sided deafness","volume":"43","year":"2022","journal-title":"Ear Hear."},{"issue":"3","key":"2026090911202384600_c12","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1159\/000444740","article-title":"Sound source localization by normal-hearing listeners, hearing-impaired listeners and cochlear implant listeners","volume":"21","year":"2016","journal-title":"Audiol. Neurotol."},{"issue":"3","key":"2026090911202384600_c13","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1044\/1092-4388(2005\/046)","article-title":"Benefit of wearing a hearing aid on the unimplanted ear in adult users of a cochlear implant","volume":"48","year":"2005","journal-title":"J. Speech Lang. Hear. Res."},{"key":"2026090911202384600_c14","first-page":"227","article-title":"Benefits of bimodal stimulation for adults with a cochlear implant","year":"2004"},{"key":"2026090911202384600_c0214578","doi-asserted-by":"publisher","first-page":"172","DOI":"10.3389\/fnins.2014.00172","article-title":"Relating age and hearing loss to monaural, bilateral, and binaural temporal sensitivity","volume":"8","year":"2014","journal-title":"Front. Neurosci."},{"key":"2026090911202384600_c15","first-page":"1","volume-title":"HRTF Measurements of a KEMAR Dummy-Head Microphone","year":"1994"},{"issue":"6","key":"2026090911202384600_c16","doi-asserted-by":"publisher","first-page":"e335","DOI":"10.1097\/AUD.0000000000000447","article-title":"Age-related differences in the processing of temporal envelope and spectral cues in a speech segment","volume":"38","year":"2017","journal-title":"Ear Hear."},{"issue":"4","key":"2026090911202384600_c17","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1097\/AUD.0b013e31806dc21a","article-title":"Horizontal-plane localization of noise and speech signals by postlingually deafened adults fitted with bilateral cochlear implants","volume":"28","year":"2007","journal-title":"Ear Hear."},{"issue":"6","key":"2026090911202384600_c18","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1097\/MAO.0000000000001043","article-title":"Cochlear implantation improves spatial release from masking and restores localization abilities in single-sided deaf patients","volume":"37","year":"2016","journal-title":"Otol. Neurotol."},{"issue":"4","key":"2026090911202384600_c19","doi-asserted-by":"publisher","first-page":"315","DOI":"10.3766\/jaaa.17112","article-title":"Psychometric comparison of the hearing in noise test and the American English Matrix test","volume":"30","year":"2019","journal-title":"J. Am. Acad. Audiol."},{"key":"2026090911202384600_c20","volume-title":"SPEAR3 Hardware Technical Manual","year":"2003"},{"issue":"S1","key":"2026090911202384600_c21","doi-asserted-by":"publisher","first-page":"S93","DOI":"10.1121\/1.2020159","article-title":"Localization of sound in rooms","volume":"72","year":"1982","journal-title":"J. Acoust. Soc. Am."},{"issue":"2","key":"2026090911202384600_c22","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1121\/1.1639908","article-title":"The benefit of binaural hearing in a cocktail party: Effect of location and type of interferer","volume":"115","year":"2004","journal-title":"J. Acoust. Soc. Am."},{"issue":"6","key":"2026090911202384600_c23","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1159\/000455058","article-title":"Towards a unified testing framework for single-sided deafness studies: A consensus paper","volume":"21","year":"2017","journal-title":"Audiol. Neurotol."},{"issue":"3","key":"2026090911202384600_c24","doi-asserted-by":"publisher","first-page":"1617","DOI":"10.1121\/1.1539520","article-title":"Speech perception, localization, and lateralization with bilateral cochlear implants","volume":"113","year":"2003","journal-title":"J. Acoust. Soc. Am."},{"issue":"1","key":"2026090911202384600_c25","doi-asserted-by":"publisher","first-page":"EL47","DOI":"10.1121\/1.4831955","article-title":"Binaural advantages in users of bimodal and bilateral cochlear implant devices","volume":"135","year":"2014","journal-title":"J. Acoust. Soc. Am."},{"issue":"suppl 2","key":"2026090911202384600_c26","doi-asserted-by":"publisher","first-page":"3","DOI":"10.3109\/14992027.2015.1020971","article-title":"The multilingual matrix test. Principles, applications, and comparison across languages: A review","volume":"54","year":"2015","journal-title":"Int. J. Audiol."},{"issue":"2","key":"2026090911202384600_c27","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1121\/1.4729575","article-title":"Spatial release from masking","volume":"8","year":"2012","journal-title":"Acoust. Today."},{"issue":"4","key":"2026090911202384600_c28","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1097\/AUD.0b013e3181a165be","article-title":"Spatial hearing and speech intelligibility in bilateral cochlear implant users","volume":"30","year":"2009","journal-title":"Ear Hear."},{"issue":"5","key":"2026090911202384600_c29","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1001\/archotol.130.5.648","article-title":"Bilateral cochlear implants in adults and children","volume":"130","year":"2004","journal-title":"Arch. Otolaryngol. Head Neck Surg."},{"issue":"1","key":"2026090911202384600_c30","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1121\/1.3036175","article-title":"Speech recognition by bilateral cochlear implant users in a cocktail-party setting","volume":"125","year":"2009","journal-title":"J. Acoust. Soc. Am."},{"issue":"1","key":"2026090911202384600_c31","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1097\/MAO.0000000000000653","article-title":"Hearing performance in single-sided deaf cochlear implant users after upgrade to a single-unit speech processor","volume":"36","year":"2015","journal-title":"Otol. Neurotol."},{"key":"2026090911202384600_c32","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1097\/AUD.0000000000001080","article-title":"Novel approaches to measure spatial release from masking in children with bilateral cochlear implants","volume":"43","year":"2022","journal-title":"Ear Hear."},{"issue":"19","key":"2026090911202384600_c1588088","doi-asserted-by":"publisher","first-page":"6133","DOI":"10.3390\/jcm12196133","article-title":"Influence of age on speech recognition in noise and hearing effort in listeners with age-related hearing loss","volume":"12","year":"2023","journal-title":"J. Clin. Med"},{"issue":"01","key":"2026090911202384600_c33","doi-asserted-by":"publisher","first-page":"003","DOI":"10.1055\/s-0031-1271945","article-title":"Bimodal hearing or bilateral cochlear implants: A review of the research literature","volume":"32","year":"2011","journal-title":"Semin. Hear."},{"issue":"3","key":"2026090911202384600_c34","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1097\/01.AUD.0000130792.43315.97","article-title":"Head shadow, squelch, and summation effects in bilateral users of the MED-EL COMBI 40\/40+ cochlear implant","volume":"25","year":"2004","journal-title":"Ear Hear."},{"issue":"3","key":"2026090911202384600_c35","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1097\/01.mao.0000169772.16045.86","article-title":"Sound localization and sensitivity to interaural cues in bilateral users of the Med-El Combi 40\/40+ cochlear implant system","volume":"26","year":"2005","journal-title":"Otol. Neurotol."},{"issue":"2","key":"2026090911202384600_c36","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1121\/1.2821965","article-title":"Localization cues with bilateral cochlear implants","volume":"123","year":"2008","journal-title":"J. Acoust. Soc. Am."},{"issue":"1","key":"2026090911202384600_c37","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1097\/AUD.0b013e31822c2549","article-title":"Development and validation of the AzBio sentence lists","volume":"33","year":"2012","journal-title":"Ear Hear."},{"key":"2026090911202384600_c38","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.1121\/1.402445","article-title":"The dominant role of low-frequency interaural time differences in sound localization","volume":"91","year":"1992","journal-title":"J. Acoust. Soc. Am."},{"key":"2026090911202384600_c39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/2331216519858311","article-title":"Spatial speech-in-noise performance in bimodal and single-sided deaf cochlear implant users","volume":"23","year":"2019","journal-title":"Trends Hear."},{"issue":"7","key":"2026090911202384600_c40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1121\/10.0012825","article-title":"Celebrating the one millionth cochlear implant","volume":"2","year":"2022","journal-title":"JASA Express Lett."},{"key":"2026090911202384600_c41","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/2331216519843876","article-title":"Reducing the device delay mismatch can improve sound localization in bimodal cochlear implant\/hearing-aid users","volume":"23","year":"2019","journal-title":"Trends Hear."}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/160\/3\/2067\/21132833\/2067_1_10.0046392.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/160\/3\/2067\/21132833\/2067_1_10.0046392.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:05:27Z","timestamp":1788969927000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/160\/3\/2067\/3404101\/Comparing-sound-localization-and-speech-in-noise"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":43,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9,1]]}},"URL":"https:\/\/doi.org\/10.1121\/10.0046392","relation":{},"ISSN":["1520-8524"],"issn-type":[{"value":"1520-8524","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,9]]},"published":{"date-parts":[[2026,9,1]]}}}