{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T01:51:10Z","timestamp":1782179470350,"version":"3.54.5"},"reference-count":54,"publisher":"Human Kinetics","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,4,1]]},"abstract":"<jats:p>To increase understanding in development of running injuries, the biomechanical load over time should be studied. Ground reaction force (GRF) is an important parameter for biomechanical analyses and is typically measured in a controlled lab environment. GRF can be estimated outdoors, however, the repeatability of this estimation is unknown. Repeatability is a crucial aspect if a measurement is repeated over prolonged periods of time. This study investigates the repeatability of a GRF estimation algorithm using inertial measurement units during outdoor running. Twelve well-trained participants completed 3 running sessions on different days, on an athletics track, instrumented with inertial measurement units on the lower legs and pelvis. Vertical accelerations were used to estimate the GRF. The goal was to assess the algorithm\u2019s repeatability across 3 sessions in a real-world setting, aiming to bridge the gap between laboratory and outdoor measurements. Results showed a good level of repeatability, with an intraclass correlation coefficient (2, k) of .86 for peak GRF, root mean square error of .08 times body weight (3.5%) and Pearson correlation coefficients exceeding .99 between the days. This is the first study looking into the day-to-day repeatability of the estimation of GRF, showing the potential to use this algorithm daily.<\/jats:p>","DOI":"10.1123\/jab.2024-0126","type":"journal-article","created":{"date-parts":[[2025,2,20]],"date-time":"2025-02-20T16:41:28Z","timestamp":1740069688000},"page":"167-178","source":"Crossref","is-referenced-by-count":3,"title":["Repeatability of Vertical Ground Reaction Force Estimation During Running on the Athletics Track on 3 Different Days"],"prefix":"10.1123","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4748-2321","authenticated-orcid":true,"given":"Bouke L.","family":"Scheltinga","sequence":"first","affiliation":[{"name":"Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands"},{"name":"Roessingh Research and Development, Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4323-1047","authenticated-orcid":true,"given":"Jaap H.","family":"Buurke","sequence":"additional","affiliation":[{"name":"Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands"},{"name":"Roessingh Research and Development, Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7352-1400","authenticated-orcid":true,"given":"Joost N.","family":"Kok","sequence":"additional","affiliation":[{"name":"Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0415-6630","authenticated-orcid":true,"given":"Jasper","family":"Reenalda","sequence":"additional","affiliation":[{"name":"Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"100","reference":[{"issue":"5","key":"r1","series-title":"J Am Coll Cardiol","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1016\/j.jacc.2014.04.058","article-title":"Leisure-time running reduces all-cause and cardiovascular mortality risk","volume":"64","author":"Lee DC","year":"2014","unstructured":"Lee DC, Pate RR, Lavie CJ, Sui X, Church TS, Blair SN. Leisure-time running reduces all-cause and cardiovascular mortality risk. J Am Coll Cardiol. 2014;64(5):472\u2013481. doi:10.1016\/j.jacc.2014.04.058"},{"issue":"8","key":"r2","series-title":"Br J Sports Med","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1136\/bjsm.2006.033548","article-title":"Incidence and determinants of lower extremity running injuries in long distance runners: a systematic review","volume":"41","author":"Van Gent RN","year":"2007","unstructured":"Van Gent RN, Siem D, Van Middelkoop M, Van Os AG, Bierma-Zeinstra SMA, Koes BW. Incidence and determinants of lower extremity running injuries in long distance runners: a systematic review. Br J Sports Med. 2007;41(8):469\u2013480. doi:10.1136\/bjsm.2006.033548"},{"issue":"5","key":"r3","series-title":"J Biomech","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1016\/0021-9290(80)90033-0","article-title":"Ground reaction forces in distance running","volume":"13","author":"Cavanagh PR","year":"1980","unstructured":"Cavanagh PR, Lafortune MA. Ground reaction forces in distance running. J Biomech. 1980;13(5):397\u2013406. doi:10.1016\/0021-9290(80)90033-0"},{"issue":"21","key":"r4","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s23218719","article-title":"Acceleration-based estimation of vertical ground reaction forces during running: a comparison of methods across running speeds, surfaces, and foot strike patterns","volume":"23","author":"Kiernan D","year":"2023","unstructured":"Kiernan D, Ng B, Hawkins DA. Acceleration-based estimation of vertical ground reaction forces during running: a comparison of methods across running speeds, surfaces, and foot strike patterns. Sensors. 2023;23(21):8719. doi:10.3390\/s23218719"},{"key":"r5","series-title":"J Biomech","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.jbiomech.2018.04.001","article-title":"Accelerometer-based prediction of running injury in National Collegiate Athletic Association track athletes","volume":"73","author":"Kiernan D","year":"2018","unstructured":"Kiernan D, Hawkins DA, Manoukian MAC, et\u00a0al. Accelerometer-based prediction of running injury in National Collegiate Athletic Association track athletes. J Biomech. 2018;73:201\u2013209. doi:10.1016\/j.jbiomech.2018.04.001"},{"issue":"12","key":"r6","series-title":"Am J Sports Med","doi-asserted-by":"publisher","first-page":"3072","DOI":"10.1177\/0363546520950731","article-title":"Impact-related ground reaction forces are more strongly associated with some running injuries than others","volume":"48","author":"Johnson CD","year":"2020","unstructured":"Johnson CD, Tenforde AS, Outerleys J, Reilly J, Davis IS. Impact-related ground reaction forces are more strongly associated with some running injuries than others. Am J Sports Med. 2020;48(12):3072\u20133080. doi:10.1177\/0363546520950731"},{"issue":"7","key":"r7","series-title":"Sports Med","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1007\/s40279-019-01110-z","article-title":"Biomechanical risk factors associated with running-related injuries : a systematic review","volume":"49","author":"Ceyssens L","year":"2019","unstructured":"Ceyssens L, Vanelderen R, Barton C, Malliaras P, Dingenen B. Biomechanical risk factors associated with running-related injuries : a systematic review. Sports Med. 2019;49(7):1095\u20131115. doi:10.1007\/s40279-019-01110-z"},{"issue":"1","key":"r8","series-title":"PLoS One","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0210000","article-title":"Ground reaction force metrics are not strongly correlated with tibial bone load when running across speeds and slopes: implications for science, sport and wearable tech","volume":"14","author":"Matijevich ES","year":"2019","unstructured":"Matijevich ES, Branscombe LM, Scott LR, Zelik KE. Ground reaction force metrics are not strongly correlated with tibial bone load when running across speeds and slopes: implications for science, sport and wearable tech. PLoS One. 2019;14(1):10000. doi:10.1371\/journal.pone.0210000"},{"issue":"3","key":"r9","series-title":"Med Sci Sports Exerc","first-page":"357","article-title":"Internal forces of chronic running injury sites","volume":"22","author":"Scott SH","year":"1990","unstructured":"Scott SH, Winter DA. Internal forces of chronic running injury sites. Med Sci Sports Exerc. 1990;22(3):357\u2013369. https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/2381304"},{"issue":"11","key":"r10","series-title":"Scand J Med Sci Sport","doi-asserted-by":"publisher","first-page":"1170","DOI":"10.1111\/sms.12883","article-title":"A framework for the etiology of running-related injuries","volume":"27","author":"Bertelsen ML","year":"2017","unstructured":"Bertelsen ML, Hulme A, Petersen J, et\u00a0al. A framework for the etiology of running-related injuries. Scand J Med Sci Sport. 2017;27(11):1170\u20131180. doi:10.1111\/sms.12883"},{"issue":"1","key":"r11","series-title":"J Appl Biomech","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1123\/jab.21.1.31","article-title":"Relationships between ground reaction force impulse and kinematics of sprint-running acceleration","volume":"21","author":"Hunter JP","year":"2005","unstructured":"Hunter JP, Marshall RN, McNair PJ. Relationships between ground reaction force impulse and kinematics of sprint-running acceleration. J Appl Biomech. 2005;21(1):31\u201343. doi:10.1123\/jab.21.1.31"},{"issue":"3","key":"r12","series-title":"J Sport Heal Sci","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/j.jshs.2021.07.002","article-title":"Longitudinal bending stiffness does not affect running economy in Nike Vaporfly Shoes","volume":"11","author":"Healey LA","year":"2022","unstructured":"Healey LA, Hoogkamer W. Longitudinal bending stiffness does not affect running economy in Nike Vaporfly Shoes. J Sport Heal Sci. 2022;11(3):285\u2013292. doi:10.1016\/j.jshs.2021.07.002"},{"issue":"8","key":"r13","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s18082564","article-title":"Indirect measurement of ground reaction forces and moments by means of wearable inertial sensors: a systematic review","volume":"18","author":"Ancillao A","year":"2018","unstructured":"Ancillao A, Tedesco S, Barton J, O\u2019flynn B. Indirect measurement of ground reaction forces and moments by means of wearable inertial sensors: a systematic review. Sensors. 2018;18(8):564. doi:10.3390\/s18082564"},{"key":"r14","series-title":"J Biomed Eng Biosci","doi-asserted-by":"publisher","DOI":"10.11159\/jbeb.2022.006","article-title":"Estimating vertical ground reaction force during running with 3 inertial measurement units","volume":"9","author":"Scheltinga BL","year":"2022","unstructured":"Scheltinga BL, Usta H, Reenalda J, Buurke JH. Estimating vertical ground reaction force during running with 3 inertial measurement units. J Biomed Eng Biosci. 2022;9:6. doi:10.11159\/jbeb.2022.006"},{"issue":"5","key":"r15","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/S22051722","article-title":"Is this the real life, or is this just laboratory? A scoping review of IMU-based running gait analysis","volume":"22","author":"Benson LC","year":"2022","unstructured":"Benson LC, R\u00e4is\u00e4nen AM, Clermont CA, Ferber R. Is this the real life, or is this just laboratory? A scoping review of IMU-based running gait analysis. Sensors. 2022;22(5):1722. doi:10.3390\/S22051722"},{"key":"r16","series-title":"Front Sport Act Living","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2023.974186","article-title":"Estimation of ground reaction force waveforms during fixed pace running outside the laboratory","volume":"5","author":"Donahue SR","year":"2023","unstructured":"Donahue SR, Hahn ME. Estimation of ground reaction force waveforms during fixed pace running outside the laboratory. Front Sport Act Living. 2023;5:186. doi:10.3389\/fspor.2023.974186"},{"issue":"1","key":"r17","series-title":"Sci Rep","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-29314-4","article-title":"Estimation of gait events and kinetic waveforms with wearable sensors and machine learning when running in an unconstrained environment","volume":"13","author":"Donahue SR","year":"2023","unstructured":"Donahue SR, Hahn ME. Estimation of gait events and kinetic waveforms with wearable sensors and machine learning when running in an unconstrained environment. Sci Rep. 2023;13(1):9314. doi:10.1038\/s41598-023-29314-4"},{"key":"r18","series-title":"Front Bioeng Biotechnol","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2020.00604","article-title":"CNN-based estimation of sagittal plane walking and running biomechanics from measured and simulated inertial sensor data","volume":"8","author":"Dorschky E","year":"2020","unstructured":"Dorschky E, Nitschke M, Martindale CF, van den Bogert AJ, Koelewijn AD, Eskofier BM. CNN-based estimation of sagittal plane walking and running biomechanics from measured and simulated inertial sensor data. Front Bioeng Biotechnol. 2020;8:604. doi:10.3389\/fbioe.2020.00604"},{"key":"r19","series-title":"Front Physiol","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2018.00218","article-title":"Estimation of vertical ground reaction forces and sagittal knee kinematics during running using three inertial sensors","volume":"9","author":"Wouda FJ","year":"2018","unstructured":"Wouda FJ, Giuberti M, Bellusci G, et\u00a0al. Estimation of vertical ground reaction forces and sagittal knee kinematics during running using three inertial sensors. Front Physiol. 2018;9:218. doi:10.3389\/fphys.2018.00218"},{"issue":"4","key":"r20","series-title":"JSME Int J Ser C","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1299\/jsmec.44.1125","article-title":"A method for gait analysis in a daily living environment by body-mounted instruments","volume":"44","author":"Ohtaki Y","year":"2001","unstructured":"Ohtaki Y, Sagawa K, Inooka H. A method for gait analysis in a daily living environment by body-mounted instruments. JSME Int J Ser C. 2001;44(4):1125\u20131132. doi:10.1299\/jsmec.44.1125"},{"key":"r21","series-title":"PeerJ Comput Sci","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.12752","article-title":"Predicting continuous ground reaction forces from accelerometers during uphill and downhill running: a recurrent neural network solution","volume":"10","author":"Alcantara RS","year":"2022","unstructured":"Alcantara RS, Edwards WB, Millet GY, Grabowski AM. Predicting continuous ground reaction forces from accelerometers during uphill and downhill running: a recurrent neural network solution. PeerJ Comput Sci. 2022;10:e12752. doi:10.7717\/peerj.12752"},{"issue":"2","key":"r22","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s19020265","article-title":"The reliability and validity of the Loadsol\u00ae under various walking and running conditions","volume":"19","author":"Renner K","year":"2019","unstructured":"Renner K, Williams D, Queen R. The reliability and validity of the Loadsol\u00ae under various walking and running conditions. Sensors. 2019;19(2):265. doi:10.3390\/s19020265"},{"issue":"6","key":"r23","series-title":"J Orthop Res","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1002\/jor.1100070611","article-title":"Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait","volume":"7","author":"Kadaba MP","year":"1989","unstructured":"Kadaba MP, Ramakrishnan HK, Wootten ME, Gainey J, Gorton G, Cochran GVB. Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait. J Orthop Res. 1989;7(6):849\u2013860. doi:10.1002\/jor.1100070611"},{"issue":"7","key":"r24","series-title":"Cochrane Database Syst Rev","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD001256.pub2","article-title":"Interventions for preventing lower limb soft-tissue running injuries","volume":"10","author":"Yeung SS","year":"2011","unstructured":"Yeung SS, Yeung EW, Gillespie LD. Interventions for preventing lower limb soft-tissue running injuries. Cochrane Database Syst Rev. 2011;10(7):CD001256. doi:10.1002\/14651858.CD001256.pub2"},{"key":"r25","series-title":"Sports Biomech","doi-asserted-by":"publisher","DOI":"10.1080\/14763141.2020.1869453","article-title":"Novel technology in sports biomechanics: some words of caution","volume":"10","author":"Hughes GTG","year":"2021","unstructured":"Hughes GTG, Camomilla V, Vanwanseele B, Harrison AJ, Fong DTP, Bradshaw EJ. Novel technology in sports biomechanics: some words of caution. Sports Biomech. 2021;10:453. doi:10.1080\/14763141.2020.1869453"},{"issue":"1\u20132","key":"r26","series-title":"Hum Mov Sci","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/0167-9457(83)90005-2","article-title":"Variations in ground reaction force parameters at different running speeds","volume":"2","author":"Hamill J","year":"1983","unstructured":"Hamill J, Bates BT, Knutzen KM, Sawhill JA. Variations in ground reaction force parameters at different running speeds. Hum Mov Sci. 1983;2(1\u20132):47\u201356. doi:10.1016\/0167-9457(83)90005-2"},{"issue":"6","key":"r27","series-title":"J Orthop Res","doi-asserted-by":"publisher","first-page":"1139","DOI":"10.1016\/S0736-0266(02)00077-3","article-title":"A comparison of within- and between-day reliability of discrete 3D lower extremity variables in runners","volume":"20","author":"Ferber R","year":"2002","unstructured":"Ferber R, McClay Davis I, Williams DS, Laughton C. A comparison of within- and between-day reliability of discrete 3D lower extremity variables in runners. J Orthop Res. 2002;20(6):1139\u20131145. doi:10.1016\/S0736-0266(02)00077-3"},{"issue":"12","key":"r28","series-title":"Med Sci Sports Exerc","doi-asserted-by":"publisher","first-page":"2253","DOI":"10.1249\/MSS.0000000000003269","article-title":"3D tibial acceleration and consideration of 3D angular motion using IMUs on peak tibial acceleration and impulse in running","volume":"55","author":"Van Middelaar RP","year":"2023","unstructured":"Van Middelaar RP, Zhang J, Veltink PH, Reenalda J. 3D tibial acceleration and consideration of 3D angular motion using IMUs on peak tibial acceleration and impulse in running. Med Sci Sports Exerc. 2023;55(12):2253\u20132262. doi:10.1249\/MSS.0000000000003269"},{"issue":"2","key":"r29","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/S24020656\/S1","article-title":"A 0.05\u00a0m change in inertial measurement unit placement alters time and frequency domain metrics during running","volume":"24","author":"Kiernan D","year":"2024","unstructured":"Kiernan D, Katzman ZD, Hawkins DA, Christiansen BA. A 0.05\u00a0m change in inertial measurement unit placement alters time and frequency domain metrics during running. Sensors. 2024;24(2):656. doi:10.3390\/S24020656\/S1"},{"key":"r30","article-title":"Xsens DOT User Manual","year":"2023","unstructured":"Movella. Xsens DOT User Manual. 2023:1\u201334. Accessed February 23, 2024. https:\/\/www.movella.com\/hubfs\/Xsens%25DOT%25User%25Manual.pdf"},{"key":"r31","unstructured":"Garmin Connect. Accessed May 21, 2024, from https:\/\/connect.garmin.com\/"},{"key":"r32","series-title":"Front Sport Act Living","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2019.00053","article-title":"Humans optimize ground contact time and leg stiffness to minimize the metabolic cost of running","volume":"1","author":"Moore IS","year":"2019","unstructured":"Moore IS, Ashford KJ, Cross C, Hope J, Jones HSR, Mccarthy-ryan M. Humans optimize ground contact time and leg stiffness to minimize the metabolic cost of running. Front Sport Act Living. 2019;1:53. doi:10.3389\/fspor.2019.00053"},{"key":"r33","series-title":"Front Sport Act Living","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2023.1176466","article-title":"Estimating 3D ground reaction forces in running using three inertial measurement units","volume":"5","author":"Scheltinga BL","year":"2023","unstructured":"Scheltinga BL, Kok JN, Buurke JH, Reenalda J. Estimating 3D ground reaction forces in running using three inertial measurement units. Front Sport Act Living. 2023;5:466. doi:10.3389\/fspor.2023.1176466"},{"issue":"2","key":"r34","series-title":"J Chiropr Med","doi-asserted-by":"publisher","DOI":"10.1016\/J.JCM.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo TK","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155. doi:10.1016\/J.JCM.2016.02.012"},{"key":"r35","series-title":"Front Bioeng Biotechnol","doi-asserted-by":"publisher","DOI":"10.3389\/FBIOE.2024.1378284\/BIBTEX","article-title":"Comparison of ground reaction forces as running speed increases between male and female runners","volume":"12","author":"Jiang X","year":"2024","unstructured":"Jiang X, B\u00edr\u00f3 I, S\u00e1rosi J, Fang Y, Gu Y. Comparison of ground reaction forces as running speed increases between male and female runners. Front Bioeng Biotechnol. 2024;12:1378284. doi:10.3389\/FBIOE.2024.1378284\/BIBTEX"},{"issue":"21","key":"r36","series-title":"J Exp Biol","doi-asserted-by":"publisher","first-page":"3406","DOI":"10.1242\/JEB.125500","article-title":"Effects of stride frequency and foot position at landing on braking force, hip torque, impact peak force and the metabolic cost of running in humans","volume":"218","author":"Lieberman DE","year":"2015","unstructured":"Lieberman DE, Warrener AG, Wang J, Castillo ER. Effects of stride frequency and foot position at landing on braking force, hip torque, impact peak force and the metabolic cost of running in humans. J Exp Biol. 2015;218(21):3406\u20133414. doi:10.1242\/JEB.125500"},{"key":"r37","series-title":"J Biomech","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2020.110130","article-title":"Continuous estimation of ground reaction force during long distance running within a fatigue monitoring framework: a Kalman filter-based model-data fusion approach","volume":"115","author":"LeBlanc B","year":"2021","unstructured":"LeBlanc B, Hernandez EM, McGinnis RS, Gurchiek RD. Continuous estimation of ground reaction force during long distance running within a fatigue monitoring framework: a Kalman filter-based model-data fusion approach. J Biomech. 2021;115:110130. doi:10.1016\/j.jbiomech.2020.110130"},{"issue":"6","key":"r38","series-title":"J Sci Med Sport","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1016\/J.JSAMS.2018.12.007","article-title":"Whole-body biomechanical load in running-based sports: the validity of estimating ground reaction forces from segmental accelerations","volume":"22","author":"Verheul J","year":"2019","unstructured":"Verheul J, Gregson W, Lisboa P, Vanrenterghem J, Robinson MA. Whole-body biomechanical load in running-based sports: the validity of estimating ground reaction forces from segmental accelerations. J Sci Med Sport. 2019;22(6):716\u2013722. doi:10.1016\/J.JSAMS.2018.12.007"},{"key":"r39","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1109\/ISSNIP.2013.6529804","article-title":"Study on estimation of peak Ground Reaction Forces using tibial accelerations in running","author":"Charry E","year":"2013","unstructured":"Charry E, Hu W, Umer M, Ronchi A, Taylor S. Study on estimation of peak Ground Reaction Forces using tibial accelerations in running. In: Palaniswami M, Leckie C, Kanhere S, Gubbi J, eds. Proceedings of the 2013 IEEE 8th International Conference on Intelligent Sensors, Sensor Networks and Information Processing: Sensing the Future. Vol 1. ISSNIP; 2013:288\u2013293. doi:10.1109\/ISSNIP.2013.6529804"},{"issue":"6","key":"r40","series-title":"PLoS One","doi-asserted-by":"publisher","DOI":"10.1371\/JOURNAL.PONE.0099023","article-title":"Ground reaction force estimates from ActiGraph GT3X+ hip accelerations","volume":"9","author":"Neugebauer JM","year":"2014","unstructured":"Neugebauer JM, Collins KH, Hawkins DA. Ground reaction force estimates from ActiGraph GT3X+ hip accelerations. PLoS One. 2014;9(6):9023. doi:10.1371\/JOURNAL.PONE.0099023"},{"key":"r41","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/J.GAITPOST.2022.09.089","article-title":"Effects of level running-induced fatigue on running kinematics: a systematic review and meta-analysis","volume":"99","author":"Zandbergen MA","year":"2023","unstructured":"Zandbergen MA, Marotta L, Bulthuis R, Buurke JH, Veltink PH, Reenalda J. Effects of level running-induced fatigue on running kinematics: a systematic review and meta-analysis. Gait Posture. 2023;99:60\u201375. doi:10.1016\/J.GAITPOST.2022.09.089"},{"issue":"11","key":"r42","series-title":"J Strength Cond Res","doi-asserted-by":"publisher","first-page":"3070","DOI":"10.1519\/JSC.0000000000003787","article-title":"The validity and reliability of global positioning system units for measuring distance and velocity during linear and team sport simulated movements","volume":"34","author":"Huggins RA","year":"2020","unstructured":"Huggins RA, Giersch GEW, Belval LN, et\u00a0al. The validity and reliability of global positioning system units for measuring distance and velocity during linear and team sport simulated movements. J Strength Cond Res. 2020;34(11):3070\u20133077. doi:10.1519\/JSC.0000000000003787"},{"key":"r43","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.gaitpost.2018.09.017","article-title":"The measurement of tibial acceleration in runners\u2014a review of the factors that can affect tibial acceleration during running and evidence-based guidelines for its use","volume":"67","author":"Sheerin KR","year":"2019","unstructured":"Sheerin KR, Reid D, Besier TF. The measurement of tibial acceleration in runners\u2014a review of the factors that can affect tibial acceleration during running and evidence-based guidelines for its use. Gait Posture. 2019;67:12\u201324. doi:10.1016\/j.gaitpost.2018.09.017"},{"key":"r44","series-title":"Proc Inst Mech Eng Part P J Sport Eng Technol","doi-asserted-by":"publisher","DOI":"10.1177\/17543371221140517","article-title":"All devices are not created equal: simultaneous data collection of three triaxial accelerometers sampling at different frequencies","volume":"10","author":"Gruber AH","year":"2022","unstructured":"Gruber AH, Marotta L, McDonnell J, Reenalda J. All devices are not created equal: simultaneous data collection of three triaxial accelerometers sampling at different frequencies. Proc Inst Mech Eng Part P J Sport Eng Technol. 2022;10:517. doi:10.1177\/17543371221140517"},{"issue":"4","key":"r45","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1016\/J.GAITPOST.2008.12.004","article-title":"Magnetic distortion in motion labs, implications for validating inertial magnetic sensors","volume":"29","author":"de Vries WHK","year":"2009","unstructured":"de Vries WHK, Veeger HEJ, Baten CTM, van der Helm FCT. Magnetic distortion in motion labs, implications for validating inertial magnetic sensors. Gait Posture. 2009;29(4):535\u2013541. doi:10.1016\/J.GAITPOST.2008.12.004"},{"issue":"7","key":"r46","series-title":"Data","doi-asserted-by":"publisher","DOI":"10.3390\/DATA6070072","article-title":"BROAD\u2014a benchmark for robust inertial orientation estimation","volume":"6","author":"Laidig D","year":"2021","unstructured":"Laidig D, Caruso M, Cereatti A, Seel T. BROAD\u2014a benchmark for robust inertial orientation estimation. Data. 2021;6(7):72. doi:10.3390\/DATA6070072"},{"issue":"2","key":"r47","series-title":"Sensors Actuators A Phys","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1016\/j.sna.2009.10.008","article-title":"Calibration methods for inertial and magnetic sensors","volume":"156","author":"Bonnet S","year":"2009","unstructured":"Bonnet S, Bassompierre C, Godin C, Lesecq S, Barraud A. Calibration methods for inertial and magnetic sensors. Sensors Actuators A Phys. 2009;156(2):302\u2013311. doi:10.1016\/j.sna.2009.10.008"},{"issue":"24","key":"r48","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s22249765","article-title":"Quantification of error sources with inertial measurement units in sports","volume":"22","author":"Kamstra H","year":"2022","unstructured":"Kamstra H, Wilmes E, van der Helm FCT. Quantification of error sources with inertial measurement units in sports. Sensors. 2022;22(24):765. doi:10.3390\/s22249765"},{"issue":"22","key":"r49","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/S22229009","article-title":"Effects of dynamic IMU-to-segment misalignment error on 3-DOF knee angle estimation in walking and running","volume":"22","author":"Jiang C","year":"2022","unstructured":"Jiang C, Yang Y, Mao H, Yang D, Wang W. Effects of dynamic IMU-to-segment misalignment error on 3-DOF knee angle estimation in walking and running. Sensors. 2022;22(22):9009. doi:10.3390\/S22229009"},{"issue":"10","key":"r50","series-title":"J Orthop Sports Phys Ther","doi-asserted-by":"publisher","first-page":"825","DOI":"10.2519\/JOSPT.2014.5367\/ASSET\/IMAGES\/LARGE\/JOSPT-825-FIG003.JPEG","article-title":"Ability of sagittal kinematic variables to estimate ground reaction forces and joint kinetics in running","volume":"44","author":"Wille CM","year":"2014","unstructured":"Wille CM, Lenhart RL, Wang S, Thelen DG, Heiderscheit BC. Ability of sagittal kinematic variables to estimate ground reaction forces and joint kinetics in running. J Orthop Sports Phys Ther. 2014;44(10):825\u2013830. doi:10.2519\/JOSPT.2014.5367\/ASSET\/IMAGES\/LARGE\/JOSPT-825-FIG003.JPEG"},{"issue":"2","key":"r51","series-title":"J Appl Biomech","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1123\/JAB.12.2.258","article-title":"The effect of environmental temperature on the properties of running shoes","volume":"12","author":"Kinoshita H","year":"1996","unstructured":"Kinoshita H, Bates BT. The effect of environmental temperature on the properties of running shoes. J Appl Biomech. 1996;12(2):258\u2013268. doi:10.1123\/JAB.12.2.258"},{"key":"r52","series-title":"RunRepeat","article-title":"Effects of temperature on running shoes","author":"Sanchez C","year":"2024","unstructured":"Sanchez C. Effects of temperature on running shoes. RunRepeat. 2024. Accessed March 4, 2024. https:\/\/runrepeat.com\/guides\/effects-temperature-running-shoes"},{"issue":"3","key":"r53","series-title":"Clin J Sport Med","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1097\/01.jsm.0000165348.32767.32","article-title":"Effect of environmental temperature on shock absorption properties of running shoes","volume":"15","author":"Dib MY","year":"2005","unstructured":"Dib MY, Smith J, Bernhardt KA, Kaufman KR, Miles KA. Effect of environmental temperature on shock absorption properties of running shoes. Clin J Sport Med. 2005;15(3):172\u2013176. doi:10.1097\/01.jsm.0000165348.32767.32"},{"issue":"1","key":"r54","series-title":"Sport Eng","doi-asserted-by":"publisher","DOI":"10.1007\/S12283-014-0162-2\/FIGURES\/13","article-title":"Modeling of shock absorption in athletics track surfaces","volume":"18","author":"Andena L","year":"2015","unstructured":"Andena L, Briatico-Vangosa F, Cazzoni E, Ciancio A, Mariani S, Pavan A. Modeling of shock absorption in athletics track surfaces. Sport Eng. 2015;18(1):162. doi:10.1007\/S12283-014-0162-2\/FIGURES\/13"}],"container-title":["Journal of Applied Biomechanics"],"original-title":[],"link":[{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jab\/41\/2\/article-p167.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jab\/41\/2\/article-p167.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jab\/41\/2\/article-p167.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,19]],"date-time":"2025-03-19T23:14:09Z","timestamp":1742426049000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jab\/41\/2\/article-p167.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,1]]},"references-count":54,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.1123\/jab.2024-0126","relation":{},"ISSN":["1065-8483","1543-2688"],"issn-type":[{"value":"1065-8483","type":"print"},{"value":"1543-2688","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,1]]}}}