{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T17:09:35Z","timestamp":1790615375205,"version":"4.1.0"},"reference-count":35,"publisher":"Human Kinetics","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,10,1]]},"abstract":"<jats:p>\n                    Marker-based motion capture is the gold standard for 3-dimensional gait analysis but is expensive and largely confined to specialized laboratories. Smartphone-based markerless tools such as OpenCap could scale gait assessment, yet their validity and repeatability during treadmill walking and running remain unclear. We evaluated agreement and within-session repeatability between OpenCap and motion capture during treadmill walking (4\u00a0km\u00b7h\n                    <jats:sup>\u22121<\/jats:sup>\n                    ) and running (8 and 14\u00a0km\u00b7h\n                    <jats:sup>\u22121<\/jats:sup>\n                    ) in 10 healthy adults, recorded simultaneously with both systems. We computed spatiotemporal variables, sagittal hip\/knee\/ankle angle waveforms and range of motion, and center-of-mass displacement waveforms and range of motion. Agreement was assessed with Bland\u2013Altman, intraclass correlation coefficients, Pearson\n                    <jats:italic>r<\/jats:italic>\n                    , and root mean square error; repeatability with trial-to-trial SD, coefficient of variation, and waveform variability index (GaitSD). Spatiotemporal metrics showed bias close to 0 and very strong associations (\n                    <jats:italic>r<\/jats:italic>\n                    \u2009\u2265\u2009.96), with small minimum detectable changes (eg,\u00a0\u22640.01\u00a0m for stride length and \u22640.03\u00a0s for temporal variables). Sagittal range of motion showed good-to-excellent reliability (bias: \u2248\u22124.5\u00b0 to 2.9\u00b0, intraclass correlation coefficients\u2009=\u2009.76\u2013.93). Waveform root mean square error was \u22481\u00b0 to 4\u00b0 for joint angles and \u22480.1 to 0.5\u00a0cm for center of mass, and statistical parametric mapping indicated only localized differences. Repeatability and GaitSD were comparable between systems across variables and speeds. Under controlled treadmill conditions, OpenCap showed comparable performance and repeatability metrics to motion capture.\n                  <\/jats:p>","DOI":"10.1123\/jab.2026-0021","type":"journal-article","created":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T16:41:23Z","timestamp":1778172083000},"page":"409-418","source":"Crossref","is-referenced-by-count":2,"title":["Agreement and Repeatability of a Smartphone-Based Markerless System (OpenCap) Versus Marker-Based Motion Capture During Treadmill Walking and Running"],"prefix":"10.1123","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9399-1098","authenticated-orcid":true,"given":"Edilson Fernando de","family":"Borba","sequence":"first","affiliation":[{"name":"Department of Physical Education, Center for Studies in Motor Behavior, Federal University of Paran\u00e1, Curitiba, PR, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-7458-9117","authenticated-orcid":true,"given":"Augusto Rossa","family":"Inda","sequence":"additional","affiliation":[{"name":"LaBiodin Biodynamics Laboratory, Department of Human Movement Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-3200-7410","authenticated-orcid":true,"given":"Bruna Machado","family":"Herberts","sequence":"additional","affiliation":[{"name":"LaBiodin Biodynamics Laboratory, Department of Human Movement Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1041-1033","authenticated-orcid":true,"given":"Lucas de Liz","family":"Alves","sequence":"additional","affiliation":[{"name":"LaBiodin Biodynamics Laboratory, Department of Human Movement Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-2126-7897","authenticated-orcid":true,"given":"Bilal Mohamad","family":"Ibrahim","sequence":"additional","affiliation":[{"name":"LaBiodin Biodynamics Laboratory, Department of Human Movement Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando Matheus de Mello","family":"Fernandes","sequence":"additional","affiliation":[{"name":"LaBiodin Biodynamics Laboratory, Department of Human Movement Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-5509-8625","authenticated-orcid":true,"given":"Nat\u00e1lia Rocha","family":"Palma","sequence":"additional","affiliation":[{"name":"LaBiodin Biodynamics Laboratory, Department of Human Movement Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-4502-6311","authenticated-orcid":true,"given":"Gustavo de Oliveira","family":"Hoffmann","sequence":"additional","affiliation":[{"name":"Department of Physical Education, Center for Studies in Motor Behavior, Federal University of Paran\u00e1, Curitiba, PR, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2335-5360","authenticated-orcid":true,"given":"Rauce Mar\u00e7al","family":"da Silva","sequence":"additional","affiliation":[{"name":"Department of Physical Education, Center for Studies in Motor Behavior, Federal University of Paran\u00e1, Curitiba, PR, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1742-5016","authenticated-orcid":true,"given":"Leonardo Alexandre","family":"Peyr\u00e9-Tartaruga","sequence":"additional","affiliation":[{"name":"Human Locomotion Laboratory (LOCOLAB), Department of Public Health, Experimental and Forensic Medicine, University of Pavia, Pavia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1173-2816","authenticated-orcid":true,"given":"Marcus Peikriszwili","family":"Tartaruga","sequence":"additional","affiliation":[{"name":"Department of Physical Education, Center for Studies in Motor Behavior, Federal University of Paran\u00e1, Curitiba, PR, Brazil"},{"name":"Department of Physical Education, Midwestern Parana State University-UNICENTRO, Guarapuava, PR, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"100","reference":[{"issue":"22","key":"r1","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s21227680","article-title":"Validation of a sensor-based gait analysis system with a gold-standard motion capture system in patients with Parkinson\u2019s disease","volume":"21","author":"Jakob V","year":"2021","unstructured":"Jakob V, K\u00fcderle A, Kluge F, et\u00a0al. Validation of a sensor-based gait analysis system with a gold-standard motion capture system in patients with Parkinson\u2019s disease. Sensors. 2021;21(22):7680. doi:10.3390\/s21227680"},{"issue":"3","key":"r2","series-title":"Res Q Exerc Sport","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1080\/02701367.2012.10599870","article-title":"The relationship between running economy and biomechanical variables in distance runners","volume":"83","author":"Tartaruga MP","year":"2012","unstructured":"Tartaruga MP, Brisswalter J, Peyr\u00e9-Tartaruga LA, et\u00a0al. The relationship between running economy and biomechanical variables in distance runners. Res Q Exerc Sport. 2012;83(3):367\u2013375. doi:10.1080\/02701367.2012.10599870"},{"issue":"3","key":"r3","series-title":"Scand J Med Sci Sports","doi-asserted-by":"publisher","first-page":"e165","DOI":"10.1111\/sms.12129","article-title":"Adaptations to changing speed, load, and gradient in human walking: cost of transport, optimal speed, and pendulum","volume":"24","author":"Gome\u00f1uka NA","year":"2014","unstructured":"Gome\u00f1uka NA, Bona RL, Da Rosa RG, Peyr\u00e9\u2010Tartaruga L. Adaptations to changing speed, load, and gradient in human walking: cost of transport, optimal speed, and pendulum. Scand J Med Sci Sports. 2014;24(3):e165\u2013e173. doi:10.1111\/sms.12129"},{"issue":"9","key":"r4","series-title":"Exp Physiol","doi-asserted-by":"publisher","first-page":"1897","DOI":"10.1113\/EP089313","article-title":"Mechanical work as a (key) determinant of energy cost in human locomotion: recent findings and future directions","volume":"106","author":"Peyr\u00e9\u2010Tartaruga LA","year":"2021","unstructured":"Peyr\u00e9\u2010Tartaruga LA, Dewolf AH, di Prampero PE, et\u00a0al. Mechanical work as a (key) determinant of energy cost in human locomotion: recent findings and future directions. Exp Physiol. 2021;106(9):1897\u20131908. doi:10.1113\/EP089313"},{"key":"r5","series-title":"J Biomech","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2021.110665","article-title":"Concurrent assessment of gait kinematics using marker-based and markerless motion capture","volume":"127","author":"Kanko RM","year":"2021","unstructured":"Kanko RM, Laende EK, Davis EM, Selbie WS, Deluzio KJ. Concurrent assessment of gait kinematics using marker-based and markerless motion capture. J Biomech. 2021;127:110665. doi:10.1016\/j.jbiomech.2021.110665"},{"issue":"1","key":"r6","series-title":"J Neuroeng Rehabil","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-023-01186-9","article-title":"A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation","volume":"20","author":"Lam WWT","year":"2023","unstructured":"Lam WWT, Tang YM, Fong KNK. A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation. J Neuroeng Rehabil. 2023;20(1):57. doi:10.1186\/s12984-023-01186-9"},{"key":"r7","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.gaitpost.2025.04.016","article-title":"Reliability and validity of current computer vision based motion capture systems in gait analysis: a systematic review","volume":"120","author":"Cheng X","year":"2025","unstructured":"Cheng X, Jiao Y, Meiring RM, Sheng B, Zhang Y. Reliability and validity of current computer vision based motion capture systems in gait analysis: a systematic review. Gait Posture. 2025;120:150\u2013160. doi:10.1016\/j.gaitpost.2025.04.016"},{"issue":"10","key":"r8","series-title":"PLoS Comput Biol","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pcbi.1011462","article-title":"OpenCap: human movement dynamics from smartphone videos","volume":"19","author":"Uhlrich SD","year":"2023","unstructured":"Uhlrich SD, Falisse A, Kidzi\u0144ski \u0141, et\u00a0al. OpenCap: human movement dynamics from smartphone videos. PLoS Comput Biol. 2023;19(10):e1011462. doi:10.1371\/journal.pcbi.1011462"},{"key":"r9","series-title":"J Biomech","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2024.112049","article-title":"Inter-trial variability is higher in 3D markerless compared to marker-based motion capture: implications for data post-processing and analysis","volume":"166","author":"Horsak B","year":"2024","unstructured":"Horsak B, Prock K, Krondorfer P, Siragy T, Simonlehner M, Dumphart B. Inter-trial variability is higher in 3D markerless compared to marker-based motion capture: implications for data post-processing and analysis. J Biomech. 2024;166:112049. doi:10.1016\/j.jbiomech.2024.112049"},{"issue":"11","key":"r10","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s24113686","article-title":"Accuracy, validity, and reliability of markerless camera-based 3D motion capture systems versus Marker-Based 3D motion capture systems in gait analysis: a systematic review and meta-analysis","volume":"24","author":"Scataglini S","year":"2024","unstructured":"Scataglini S, Abts E, Van Bocxlaer C, Van den Bussche M, Meletani S, Truijen S.Accuracy, validity, and reliability of markerless camera-based 3D motion capture systems versus Marker-Based 3D motion capture systems in gait analysis: a systematic review and meta-analysis. Sensors. 2024;24(11):3686. doi:10.3390\/s24113686"},{"key":"r11","series-title":"J Biomech","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2023.111801","article-title":"Concurrent validity of smartphone-based markerless motion capturing to quantify lower-limb joint kinematics in healthy and pathological gait","volume":"159","author":"Horsak B","year":"2023","unstructured":"Horsak B, Eichmann A, Lauer K, et\u00a0al. Concurrent validity of smartphone-based markerless motion capturing to quantify lower-limb joint kinematics in healthy and pathological gait. J Biomech. 2023;159:111801. doi:10.1016\/j.jbiomech.2023.111801"},{"issue":"10","key":"r12","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s24103091","article-title":"A step forward understanding directional limitations in markerless smartphone-based GAIT analysis: a pilot study","volume":"24","author":"Marti\u0161 P","year":"2024","unstructured":"Marti\u0161 P, Ko\u0161utzk\u00e1 Z, Kranzl A. A step forward understanding directional limitations in markerless smartphone-based GAIT analysis: a pilot study. Sensors. 2024;24(10):3091. doi:10.3390\/s24103091"},{"key":"r13","series-title":"J Biomech","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2025.112602","article-title":"Validation of OpenCap on lower extremity kinematics during functional tasks","volume":"183","author":"Svetek A","year":"2025","unstructured":"Svetek A, Morgan K, Burland J, Glaviano NR. Validation of OpenCap on lower extremity kinematics during functional tasks. J Biomech. 2025;183:112602. doi:10.1016\/j.jbiomech.2025.112602"},{"key":"r14","series-title":"J Biomech","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2024.112200","article-title":"Validation of OpenCap: a low-cost markerless motion capture system for lower-extremity kinematics during return-to-sport tasks","volume":"171","author":"Turner JA","year":"2024","unstructured":"Turner JA, Chaaban CR, Padua DA. Validation of OpenCap: a low-cost markerless motion capture system for lower-extremity kinematics during return-to-sport tasks. J Biomech. 2024;171:112200. doi:10.1016\/j.jbiomech.2024.112200"},{"issue":"4","key":"r15","series-title":"Sports Med","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1007\/s40279-019-01237-z","article-title":"Is motorized treadmill running biomechanically comparable to overground running? A systematic review and meta-analysis of cross-over studies","volume":"50","author":"Van Hooren B","year":"2020","unstructured":"Van Hooren B, Fuller JT, Buckley JD, et\u00a0al. Is motorized treadmill running biomechanically comparable to overground running? A systematic review and meta-analysis of cross-over studies. Sports Med. 2020;50(4):785\u2013813. doi:10.1007\/s40279-019-01237-z"},{"issue":"5","key":"r16","series-title":"J Med Eng Technol","doi-asserted-by":"publisher","first-page":"274","DOI":"10.3109\/03091902.2014.909540","article-title":"Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis","volume":"38","author":"Pfister A","year":"2014","unstructured":"Pfister A, West AM, Bronner S, Noah JA. Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis. J Med Eng Technol. 2014;38(5):274\u2013280. doi:10.3109\/03091902.2014.909540"},{"issue":"1","key":"r17","series-title":"Med Eng Phys","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.medengphy.2018.04.020","article-title":"Accuracy of a novel marker tracking approach based on the low-cost Microsoft Kinect v2 sensor","volume":"59","author":"Timmi A","year":"2018","unstructured":"Timmi A, Coates G, Fortin K, et\u00a0al. Accuracy of a novel marker tracking approach based on the low-cost Microsoft Kinect v2 sensor. Med Eng Phys. 2018;59(1):63\u201369. doi:10.1016\/j.medengphy.2018.04.020"},{"issue":"2","key":"r18","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.gaitpost.2015.05.002","article-title":"Accuracy of the Microsoft KinectTM for measuring gait parameters during treadmill walking","volume":"42","author":"Xu X","year":"2015","unstructured":"Xu X, McGorry RW, Chou LS, Lin JH, Chang CC. Accuracy of the Microsoft KinectTM for measuring gait parameters during treadmill walking. Gait Posture. 2015;42(2):145\u2013151. doi:10.1016\/j.gaitpost.2015.05.002"},{"issue":"5","key":"r19","series-title":"J Appl Biomech","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1123\/jab.2024-0092","article-title":"Fatigue-related changes in running technique and mechanical variables after a maximal incremental test in recreational runners","volume":"40","author":"de Borba EF","year":"2024","unstructured":"de Borba EF, da Silva ES, de Liz Alves L, et\u00a0al. Fatigue-related changes in running technique and mechanical variables after a maximal incremental test in recreational runners. J Appl Biomech. 2024;40(5):424\u2013431. doi:10.1123\/jab.2024-0092"},{"issue":"12","key":"r20","series-title":"Ann Biomed Eng","doi-asserted-by":"publisher","first-page":"2762","DOI":"10.1007\/s10439-017-1920-7","article-title":"Why are antagonist muscles co-activated in my simulation? A musculoskeletal model for analysing human locomotor tasks","volume":"45","author":"Lai AKM","year":"2017","unstructured":"Lai AKM, Arnold AS, Wakeling JM. Why are antagonist muscles co-activated in my simulation? A musculoskeletal model for analysing human locomotor tasks. Ann Biomed Eng. 2017;45(12):2762\u20132774. doi:10.1007\/s10439-017-1920-7"},{"issue":"10","key":"r21","series-title":"IEEE Trans Biomed Eng","doi-asserted-by":"publisher","first-page":"2068","DOI":"10.1109\/TBME.2016.2586891","article-title":"Full-body musculoskeletal model for muscle-driven simulation of human gait","volume":"63","author":"Rajagopal A","year":"2016","unstructured":"Rajagopal A, Dembia CL, DeMers MS, Delp DD, Hicks JL, Delp SL. Full-body musculoskeletal model for muscle-driven simulation of human gait. IEEE Trans Biomed Eng. 2016;63(10):2068\u20132079. doi:10.1109\/TBME.2016.2586891"},{"issue":"4","key":"r22","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1016\/j.gaitpost.2007.07.007","article-title":"Two simple methods for determining gait events during treadmill and overground walking using kinematic data","volume":"27","author":"Zeni JA Jr","year":"2008","unstructured":"Zeni JA Jr, Richards JG, Higginson J. Two simple methods for determining gait events during treadmill and overground walking using kinematic data. Gait Posture. 2008;27(4):710\u2013714. doi:10.1016\/j.gaitpost.2007.07.007"},{"key":"r23","series-title":"J Biomech","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2021.110737","article-title":"A novel kinematic detection of foot-strike and toe-off events during noninstrumented treadmill running to estimate contact time","volume":"128","author":"Patoz A","year":"2021","unstructured":"Patoz A, Lussiana T, Gindre C, Malatesta D. A novel kinematic detection of foot-strike and toe-off events during noninstrumented treadmill running to estimate contact time. J Biomech. 2021;128:110737. doi:10.1016\/j.jbiomech.2021.110737"},{"issue":"5","key":"r24","series-title":"Anesth Analg","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","article-title":"Correlation coefficients: appropriate use and interpretation","volume":"126","author":"Schober P","year":"2018","unstructured":"Schober P, Boer C, Schwarte LA. Correlation coefficients: appropriate use and interpretation. Anesth Analg. 2018;126(5):1763\u20131768. doi:10.1213\/ANE.0000000000002864"},{"issue":"2","key":"r25","series-title":"J Chiropr Med","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo TK","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155\u2013163. doi:10.1016\/j.jcm.2016.02.012"},{"issue":"3","key":"r26","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.gaitpost.2008.09.003","article-title":"The reliability of three-dimensional kinematic gait measurements: a systematic review","volume":"29","author":"McGinley JL","year":"2009","unstructured":"McGinley JL, Baker R, Wolfe R, Morris ME. The reliability of three-dimensional kinematic gait measurements: a systematic review. Gait Posture. 2009;29(3):360\u2013369. doi:10.1016\/j.gaitpost.2008.09.003"},{"key":"r27","series-title":"J Rehabil Med","doi-asserted-by":"publisher","first-page":"456","DOI":"10.2340\/16501977-2559","article-title":"Concurrent validity and reliability of a low-cost gait analysis system for assessment of spatiotemporal gait parameters","volume":"51","author":"Bloemendaal MV","year":"2019","unstructured":"Bloemendaal MV, Beelen A, Kleissen RFM, Geurts ACH, Nollet F, Bus SA. Concurrent validity and reliability of a low-cost gait analysis system for assessment of spatiotemporal gait parameters. J Rehabil Med. 2019;51:456\u2013463. doi:10.2340\/16501977-2559"},{"issue":"1","key":"r28","series-title":"Encycl Meas Stat","article-title":"Bonferroni and \u0160id\u00e1k corrections for multiple comparisons","volume":"3","author":"Abdi H","year":"2007","unstructured":"Abdi H. Bonferroni and \u0160id\u00e1k corrections for multiple comparisons. Encycl Meas Stat. 2007;3(1):2007."},{"key":"r29","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1016\/j.gaitpost.2016.03.015","article-title":"The gait standard deviation, a single measure of kinematic variability","volume":"46","author":"Sangeux M","year":"2016","unstructured":"Sangeux M, Passmore E, Graham HK, Tirosh O. The gait standard deviation, a single measure of kinematic variability. Gait Posture. 2016;46:194\u2013200. doi:10.1016\/j.gaitpost.2016.03.015"},{"issue":"20","key":"r30","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s25206474","article-title":"Effect of walking speed on the reliability of a smartphone-based markerless gait analysis system","volume":"25","author":"de Borba EF","year":"2025","unstructured":"de Borba EF, Storniolo JL, Cerfoglio S, et\u00a0al. Effect of walking speed on the reliability of a smartphone-based markerless gait analysis system. Sensors. 2025;25(20):474. doi:10.3390\/s25206474"},{"issue":"19","key":"r31","series-title":"J Sports Sci","doi-asserted-by":"publisher","first-page":"1847","DOI":"10.1080\/02640414.2024.2415233","article-title":"Validity and reliability of trunk and lower-limb kinematics during squatting, hopping, jumping and side-stepping using OpenCap markerless motion capture application","volume":"42","author":"Lima YL","year":"2024","unstructured":"Lima YL, Collings T, Hall M, Bourne MN, Diamond LE. Validity and reliability of trunk and lower-limb kinematics during squatting, hopping, jumping and side-stepping using OpenCap markerless motion capture application. J Sports Sci. 2024;42(19):1847\u20131858. doi:10.1080\/02640414.2024.2415233"},{"key":"r32","series-title":"Biol Sport","doi-asserted-by":"publisher","DOI":"10.5114\/biolsport.2026.154942","article-title":"Can OpenCap deliver valid and reliable kinematic data for motion analysis? A systematic review and three-level meta-analysis","volume":"10","author":"\u00c7abuk S","year":"2026","unstructured":"\u00c7abuk S, Ulup\u0131nar S, \u0130nce \u0130, \u00d6zbay S. Can OpenCap deliver valid and reliable kinematic data for motion analysis? A systematic review and three-level meta-analysis. Biol Sport. 2026;10:942. doi:10.5114\/biolsport.2026.154942"},{"issue":"4","key":"r33","series-title":"Biomechanics","doi-asserted-by":"publisher","DOI":"10.3390\/biomechanics5040088","article-title":"Smartphone-based gait analysis with OpenCap: a narrative review","volume":"5","author":"Cerfoglio S","year":"2025","unstructured":"Cerfoglio S, Lopes Storniolo J, de Borba EF, et\u00a0al. Smartphone-based gait analysis with OpenCap: a narrative review. Biomechanics. 2025;5(4):88. doi:10.3390\/biomechanics5040088"},{"issue":"1","key":"r34","series-title":"PLoS One","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0316119","article-title":"Reliability of artificial intelligence-driven markerless motion capture in gait analyses of healthy adults","volume":"20","author":"Schoenwether B","year":"2025","unstructured":"Schoenwether B, Ripic Z, Nienhuis M, Signorile JF, Best TM, Eltoukhy M. Reliability of artificial intelligence-driven markerless motion capture in gait analyses of healthy adults. PLoS One. 2025;20(1):e0316119. doi:10.1371\/journal.pone.0316119"},{"key":"r35","series-title":"J Biomech","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2024.112281","article-title":"Repeatability and minimal detectable change including clothing effects for smartphone-based 3D markerless motion capture","volume":"175","author":"Horsak B","year":"2024","unstructured":"Horsak B, Kainz H, Dumphart B. Repeatability and minimal detectable change including clothing effects for smartphone-based 3D markerless motion capture. J Biomech. 2024;175:112281. doi:10.1016\/j.jbiomech.2024.112281"}],"container-title":["Journal of Applied Biomechanics"],"original-title":[],"link":[{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jab\/42\/5\/article-p409.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jab\/42\/5\/article-p409.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jab\/42\/5\/article-p409.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T16:17:02Z","timestamp":1790612222000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jab\/42\/5\/article-p409.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,1]]},"references-count":35,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.1123\/jab.2026-0021","relation":{},"ISSN":["1065-8483","1543-2688"],"issn-type":[{"value":"1065-8483","type":"print"},{"value":"1543-2688","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,1]]}}}