{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T01:28:49Z","timestamp":1793842129006,"version":"4.6.1"},"reference-count":10,"publisher":"Human Kinetics","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,8,1]]},"abstract":"<jats:p>\n                    <jats:italic>\n                      <jats:bold>Context<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Measuring isometric shoulder rotational strength is clinically important for evaluating motor disability in athletes with shoulder injuries. Recent evidence suggests that handheld dynamometry may provide a low-cost and portable method for the clinical assessment of isometric shoulder strength.\n                    <jats:italic>\n                      <jats:bold>Objective<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    To investigate the concurrent validity and the intrarater and interrater reliability of handheld dynamometry for measuring isometric shoulder rotational strength.\n                    <jats:italic>\n                      <jats:bold>Design<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Cross-sectional study.\n                    <jats:italic>\n                      <jats:bold>Setting<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Biomechanics laboratory.\n                    <jats:italic>\n                      <jats:bold>Participants<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Thirty-nine young, healthy participants.\n                    <jats:italic>\n                      <jats:bold>Main Outcome Measures<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    The peak isometric strength of the internal rotators and external rotators, measured by handheld dynamometry (in newton) and isokinetic dynamometry (in newton meter).\n                    <jats:italic>\n                      <jats:bold>Interventions<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Maximal isometric shoulder rotational strength was measured as participants lay supine with 90\u00b0 shoulder abduction, neutral rotation, 90\u00b0 elbow flexion, and forearm pronation. Measurements were performed independently by 2 different physiotherapists and in 3 different sessions to evaluate interrater and intrarater reliability. The data obtained by handheld dynamometry were compared with those obtained by isokinetic testing to evaluate concurrent validity.\n                    <jats:italic>\n                      <jats:bold>Results<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    The intraclass correlation coefficients for interrater reliability in measuring maximum isometric shoulder external and internal rotation strength were .914 (95% confidence interval [CI], .842\u2013.954) and .842 (95% CI, .720\u2013.914), respectively. The intrarater reliability values of the method for measuring maximal shoulder external and internal rotation strength were 0.865 (95% CI, 0.757\u20130.927) and 0.901 (95% CI, 0.820\u20130.947), respectively. The Pearson correlation coefficients between the handheld and isokinetic dynamometer measurements were .792 (95% CI, .575\u2013.905) for external rotation strength and .664 (95% CI, .419\u2013.839) for internal rotation strength.\n                    <jats:italic>\n                      <jats:bold>Conclusions<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    The handheld dynamometer showed good to excellent reliability and moderate to good validity in measuring maximum isometric shoulder rotational strength. Therefore, handheld dynamometry could be acceptable for health and sports professionals in field situations to evaluate maximum isometric shoulder rotational strength.\n                  <\/jats:p>","DOI":"10.1123\/jsr.2020-0021","type":"journal-article","created":{"date-parts":[[2021,1,19]],"date-time":"2021-01-19T02:09:15Z","timestamp":1611022155000},"page":"965-968","source":"Crossref","is-referenced-by-count":33,"title":["Concurrent Validity and Reliability of a Handheld Dynamometer in Measuring Isometric Shoulder Rotational Strength"],"prefix":"10.1123","volume":"30","author":[{"given":"Bin","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lifen","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lincoln","family":"Bin Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianxin","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenhao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Qi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"100","reference":[{"issue":"7","key":"r1","series-title":"Am J Sports Med","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1177\/0363546509360404","article-title":"Preseason shoulder strength measurements in professional baseball pitchers: identifying players at risk for injury","volume":"38","author":"Byram IR","year":"2010","unstructured":"Byram IR, Bushnell BD, Dugger K, Charron K, Harrell FE Jr, Noonan TJ. Preseason shoulder strength measurements in professional baseball pitchers: identifying players at risk for injury. Am J Sports Med. 2010;38(7):1375\u20131382. PubMed ID: 20489215 doi:10.1177\/036354650936040410.1177\/036354650936040420489215"},{"issue":"1","key":"r2","series-title":"J Sci Med Sport","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.jsams.2017.05.003","article-title":"Isometric shoulder strength in young swimmers","volume":"21","author":"McLaine SJ","year":"2018","unstructured":"McLaine SJ, Ginn KA, Fell JW, Bird ML. Isometric shoulder strength in young swimmers. J Sci Med Sport. 2018;21(1):35\u201339. PubMed ID: 28844605 doi:10.1016\/j.jsams.2017.05.0032884460510.1016\/j.jsams.2017.05.003"},{"issue":"1","key":"r3","series-title":"Man Ther","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.math.2010.05.005","article-title":"Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength","volume":"16","author":"Cadogan A","year":"2011","unstructured":"Cadogan A, Laslett M, Hing W, McNair P, Williams M. Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength. Man Ther. 2011; 16(1):97\u2013101. PubMed ID: 20621547 doi:10.1016\/j.math.2010.05.00510.1016\/j.math.2010.05.00520621547"},{"issue":"15","key":"r4","series-title":"J Sports Sci","doi-asserted-by":"publisher","first-page":"1787","DOI":"10.1080\/02640414.2019.1594570","article-title":"Validity and reliability of a low-cost dynamometer to assess maximal isometric strength of upper limb","volume":"37","author":"Romero-Franco N","year":"2019","unstructured":"Romero-Franco N, Fernandez-Dominguez JC, Montano-Munuera JA, Romero-Franco J, Jimenez-Reyes P. Validity and reliability of a low-cost dynamometer to assess maximal isometric strength of upper limb. J Sports Sci. 2019;37(15):1787\u20131793. PubMed ID: 30897030 doi:10.1080\/02640414.2019.159457010.1080\/02640414.2019.159457030897030"},{"issue":"4","key":"r5","series-title":"Shoulder Elbow","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1111\/j.1758-5740.2011.00137.x","article-title":"Assessing the reliability of shoulder strength measurement hand-held versus fixed dynamometry","volume":"3","author":"Beshay N","year":"2011","unstructured":"Beshay N, Lam PH, Murrell AC. Assessing the reliability of shoulder strength measurement hand-held versus fixed dynamometry. Shoulder Elbow. 2011;3(4):244\u2013251. doi:10.1111\/j.1758-5740.2011.00137.x10.1111\/j.1758-5740.2011.00137.x"},{"issue":"8","key":"r6","series-title":"J Shoulder Elbow Surg","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1016\/j.jse.2010.05.021","article-title":"Hand-held dynamometer testing of the internal and external rotator musculature based on selected positions to establish normative data and unilateral ratios","volume":"19","author":"Riemann BL","year":"2010","unstructured":"Riemann BL, Davies GJ, Ludwig L, Gardenhour H. Hand-held dynamometer testing of the internal and external rotator musculature based on selected positions to establish normative data and unilateral ratios. J Shoulder Elbow Surg. 2010;19(8):1175\u20131183. PubMed ID: 20850997 doi:10.1016\/j.jse.2010.05.0212085099710.1016\/j.jse.2010.05.021"},{"issue":"10","key":"r7","series-title":"J Clin Epidemiol","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/j.jclinepi.2005.10.015","article-title":"When to use agreement versus reliability measures","volume":"59","author":"de Vet HC","year":"2006","unstructured":"de Vet HC, Terwee CB, Knol DL, Bouter LM. When to use agreement versus reliability measures. J Clin Epidemiol. 2006;59(10):1033\u20131039. PubMed ID: 16980142 doi:10.1016\/j.jclinepi.2005.10.01510.1016\/j.jclinepi.2005.10.015"},{"key":"r8","series-title":"Foundations of Clinical Research: Applications to Practice","author":"Portney LG","year":"2015","unstructured":"Portney LG, Watkins MP. Foundations of Clinical Research: Applications to Practice. 3rd ed. Upper Saddle River, NJ: Pearson\/Prentice Hall: F. A. Davis PT; 2015."},{"issue":"2","key":"r9","series-title":"J Sport Rehabil","doi-asserted-by":"publisher","first-page":"2015","DOI":"10.1123\/jsr.2015-0034","article-title":"The reliability of strength tests performed in elevated shoulder positions using a handheld dynamometer","volume":"25","author":"McLaine SJ","year":"2016","unstructured":"McLaine SJ, Ginn KA, Kitic CM, Fell JW, Bird ML. The reliability of strength tests performed in elevated shoulder positions using a handheld dynamometer. J Sport Rehabil. 2016;25(2):2015. PubMed ID: 26355715 doi:10.1123\/jsr.2015-003410.1123\/jsr.2015-003426355715"},{"issue":"2","key":"r10","series-title":"Man Ther","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1054\/math.2000.0241","article-title":"Functional stability of the glenohumeral joint","volume":"5","author":"Hess SA","year":"2000","unstructured":"Hess SA. Functional stability of the glenohumeral joint. Man Ther. 2000;5(2):63\u201371. PubMed ID: 10903581 doi:10.1054\/math.2000.02411090358110.1054\/math.2000.0241"}],"container-title":["Journal of Sport Rehabilitation"],"original-title":[],"link":[{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jsr\/30\/6\/article-p965.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jsr\/30\/6\/article-p965.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jsr\/30\/6\/article-p965.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T01:14:02Z","timestamp":1793841242000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jsr\/30\/6\/article-p965.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,1]]},"references-count":10,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.1123\/jsr.2020-0021","relation":{},"ISSN":["1056-6716","1543-3072"],"issn-type":[{"value":"1056-6716","type":"print"},{"value":"1543-3072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,1]]}}}