{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T21:34:00Z","timestamp":1783719240697,"version":"3.55.0"},"reference-count":20,"publisher":"Human Kinetics","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,11,1]]},"abstract":"<jats:p><jats:italic><jats:bold>Context<\/jats:bold>:<\/jats:italic>\u00a0 Clinical assessment of scapular motion is obscured by a lack of clinically accessible and feasible angular measurement tools. This study evaluates the reliability and validity of the smartphone \u201cClinometer\u201d app in measuring scapular upward rotation (UR) and anteroposterior tilt. <jats:italic><jats:bold>Design<\/jats:bold>:<\/jats:italic> Psychometric analysis. <jats:italic><jats:bold>Methods<\/jats:bold>:<\/jats:italic> We recruited 57 participants\u201410 with and 47 without shoulder pain. Two physical therapists consecutively measured both scapular movements using the Clinometer app at the arm by the side (rest), 30\u00b0, 60\u00b0, 90\u00b0, and 120\u00b0 of humeral elevation in the scapular plane; one therapist measured again after 2\u00a0days. For evaluating concurrent validity, we compared the Clinometer scores with those measured using an electromagnetic motion capture system in 10 healthy participants. Intraclass correlation coefficients (ICC) with standard error of measurement (SEM) and minimal detectable difference at 90% confidence intervals (MDD<jats:sub>90<\/jats:sub>) were calculated. Concurrent validity was evaluated using repeated-measures analysis of variance followed by post hoc testing with Tukey\u2013Kramer test (<jats:italic>P<\/jats:italic>\u2009&lt;\u2009.05). <jats:italic><jats:bold>Results<\/jats:bold>:<\/jats:italic> We observed good intrarater reliability (ICC: UR\u2009=\u2009.76\u2013.85, tilt\u2009=\u2009.69\u2013.9; SEM: 2.2\u00b0\u20133.5\u00b0; MDD<jats:sub>90<\/jats:sub>: \u223c5\u00b0\u20138\u00b0) and moderate to good interrater reliability (ICC: UR\u2009=\u2009.66\u2013.78, tilt\u2009=\u2009.66\u2013.76; SEM: 3.6\u00b0\u20138\u00b0; MDD<jats:sub>90<\/jats:sub>: \u223c9\u00b0\u201318\u00b0) for both rotations. The Clinometer scores for UR were comparable to electromagnetic motion capture system at all angles except 90\u00b0 (difference \u223c8\u00b0); for scapular tilt, the scores were comparable only at rest and 30\u00b0 elevation. <jats:italic><jats:bold>Conclusion<\/jats:bold>:<\/jats:italic> The Clinometer app is reliable and valid for measuring scapular UR throughout and for scapular tilt at lower humeral elevation angles. The MDD<jats:sub>90<\/jats:sub> values for scapular rotations computed in this study can be helpful in rehabilitation planning and future research.<\/jats:p>","DOI":"10.1123\/jsr.2023-0005","type":"journal-article","created":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T08:34:18Z","timestamp":1693298058000},"page":"926-931","source":"Crossref","is-referenced-by-count":3,"title":["Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain"],"prefix":"10.1123","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6901-7618","authenticated-orcid":true,"given":"Varmeet","family":"Kaur","sequence":"first","affiliation":[{"name":"Indian Spinal Injuries Centre, Institute of Rehabilitation Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3395-2214","authenticated-orcid":true,"given":"Meena","family":"Makhija","sequence":"additional","affiliation":[{"name":"Indian Spinal Injuries Centre, Institute of Rehabilitation Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8840-1487","authenticated-orcid":true,"given":"Vandana","family":"Phadke","sequence":"additional","affiliation":[{"name":"Department of Research, Indian Spinal Injuries Centre, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"100","reference":[{"key":"r1","series-title":"Phys Ther","first-page":"1162","article-title":"Critical and theoretical perspective on scapular stabilization: what does it really mean, and are we on the right track?","volume":"96","author":"Mcquade KJ","year":"2016","unstructured":"Mcquade KJ, Borstad J, Siriani De Oliveira A, Mcquade KJ, Borstad J, De Oliveira AS. Critical and theoretical perspective on scapular stabilization: what does it really mean, and are we on the right track? Phys Ther. 2016;96:1162\u20131169. https:\/\/academic.oup.com\/ptj\/article\/96\/8\/1162\/2864874"},{"issue":"7","key":"r2","series-title":"Physiother Theory Pract","first-page":"453","article-title":"Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review","volume":"30","author":"Larsen CM","year":"2014","unstructured":"Larsen CM, Juul-Kristensen B, Lund H, S\u00f8gaard K. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review. Physiother Theory Pract. 2014;30(7):453\u2013482. doi:10.3109\/09593985.2014.899414"},{"issue":"11","key":"r3","series-title":"J Orthop Sports Phys Ther","first-page":"632","article-title":"Validity of clinical measurement instruments assessing scapular function: insufficient evidence to recommend any instrument for assessing scapular posture, movement, and dysfunction\u2014a systematic review","volume":"50","author":"D\u2019Hondt NE","year":"2020","unstructured":"D\u2019Hondt NE, Pool JJM, Kiers H, Terwee CB, Veeger HEJ. Validity of clinical measurement instruments assessing scapular function: insufficient evidence to recommend any instrument for assessing scapular posture, movement, and dysfunction\u2014a systematic review. J Orthop Sports Phys Ther. 2020;50(11):632\u2013641. doi:10.2519\/jospt.2020.9265"},{"issue":"10","key":"r4","series-title":"J Biomech","first-page":"2219","article-title":"Validity and reliability of 3D marker based scapular motion analysis: a systematic review","volume":"47","author":"Lempereur M","year":"2014","unstructured":"Lempereur M, Brochard S, Leboeuf F, R\u00e9my-N\u00e9ris O. Validity and reliability of 3D marker based scapular motion analysis: a systematic review. J Biomech. 2014;47(10):2219\u20132230. doi:10.1016\/j.jbiomech.2014.04.028"},{"issue":"6","key":"r5","series-title":"J Sport Rehabil","first-page":"650","article-title":"Reliability of clinical assessment methods to measure scapular upward rotation: a critically appraised topic","volume":"28","author":"Silverson O","year":"2019","unstructured":"Silverson O, Cascia N, Hettrich CM, Hoch M, Uhl T. Reliability of clinical assessment methods to measure scapular upward rotation: a critically appraised topic. J Sport Rehabil. 2019;28(6):650\u2013655. doi:10.1123\/JSR.2018-0012"},{"issue":"2","key":"r6","series-title":"Physiother Theory Pract","first-page":"121","article-title":"Concurrent validity of inclinometer measures of scapular and clavicular positions in arm elevation","volume":"34","author":"Camargo PR","year":"2018","unstructured":"Camargo PR, Phadke V, Zanca GG, Ludewig PM. Concurrent validity of inclinometer measures of scapular and clavicular positions in arm elevation. Physiother Theory Pract. 2018;34(2):121\u2013130. doi:10.1080\/09593985.2017.1370753"},{"issue":"5","key":"r7","series-title":"Int J Sports Phys Ther","first-page":"644","article-title":"Validation of a new method for assessing scapular anterior-posterior tilt","volume":"9","author":"Scibek JS","year":"2014","unstructured":"Scibek JS, Carcia CR. Validation of a new method for assessing scapular anterior-posterior tilt. Int J Sports Phys Ther. 2014;9(5):644\u2013656. PubMed ID: 25328827"},{"issue":"6","key":"r8","series-title":"J Athl Train","first-page":"586","article-title":"Reliability and validity of a clinical assessment tool for measuring scapular motion in all 3 anatomical planes","volume":"56","author":"Silverson OA","year":"2021","unstructured":"Silverson OA, Lemaster NG, Hettrich CM, Heebner NR, Uhl TL. Reliability and validity of a clinical assessment tool for measuring scapular motion in all 3 anatomical planes. J Athl Train. 2021;56(6):586\u2013593. doi:10.4085\/276-20"},{"issue":"5","key":"r9","series-title":"PLoS One","article-title":"Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: a systematic review","volume":"14","author":"Keogh JWL","year":"2019","unstructured":"Keogh JWL, Cox A, Anderson S, et\u00a0al. Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: a systematic review. PLoS One. 2019;14(5):806. doi:10.1371\/journal.pone.0215806"},{"issue":"1","key":"r10","series-title":"J Clin Epidemiol","first-page":"96","article-title":"Guidelines for reporting reliability and agreement studies (GRRAS) were proposed","volume":"64","author":"Kottner J","year":"2011","unstructured":"Kottner J, Audig\u00e9 L, Brorson S, et\u00a0al. Guidelines for reporting reliability and agreement studies (GRRAS) were proposed. J Clin Epidemiol. 2011;64(1):96\u2013106. doi:10.1016\/j.jclinepi.2010.03.002"},{"key":"r11","unstructured":"Clinometer | plaincode. https:\/\/www.plaincode.com\/products\/clinometer\/. Accessed June 2, 2020."},{"issue":"5","key":"r12","series-title":"J Biomech","first-page":"981","article-title":"ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion - Part II: shoulder, elbow, wrist and hand","volume":"38","author":"Wu G","year":"2005","unstructured":"Wu G, Van Der Helm FCT, Veeger HEJ, et\u00a0al. ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion - Part II: shoulder, elbow, wrist and hand. J Biomech. 2005;38(5):981\u2013992. doi:10.1016\/j.jbiomech.2004.05.042"},{"issue":"2","key":"r13","series-title":"J Chiropr Med","first-page":"155","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo TK","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155\u2013163. doi:10.1016\/j.jcm.2016.02.012"},{"key":"r14","series-title":"Foundations of Clinical Research Application to Practice","author":"Portney LG","year":"2009","unstructured":"Portney LG, Watkins MP. Foundations of Clinical Research Application to Practice. 3rd ed. F.A. Davis Company; 2009."},{"issue":"1","key":"r15","series-title":"J Athl Train","first-page":"12","article-title":"Scapular-positioning patterns during humeral elevation in unimpaired shoulders","volume":"38","author":"Borsa PA","year":"2003","unstructured":"Borsa PA, Timmons MK, Sauers EL. Scapular-positioning patterns during humeral elevation in unimpaired shoulders. J Athl Train. 2003;38(1):12\u201317. PubMed ID: 12937466"},{"issue":"1","key":"r16","series-title":"Man Ther","first-page":"26","article-title":"Validity and reliability of palpation-digitization for non-invasive kinematic measurement\u2014a systematic review","volume":"18","author":"Adhia DB","year":"2013","unstructured":"Adhia DB, Bussey MD, Ribeiro DC, Tumilty S, Milosavljevic S. Validity and reliability of palpation-digitization for non-invasive kinematic measurement\u2014a systematic review. Man Ther. 2013;18(1):26\u201334. doi:10.1016\/j.math.2012.06.004"},{"issue":"3","key":"r17","series-title":"J Bone Joint Surg","first-page":"99","article-title":"Evaluating agreement","volume":"91-A","author":"Karanicolas PJ","year":"2009","unstructured":"Karanicolas PJ, Bhandari M, Kreder H, et\u00a0al. Evaluating agreement. J Bone Joint Surg. 2009;91-A(3):99\u2013106. doi:10.2106\/JBJS.H.01624"},{"issue":"2","key":"r18","series-title":"J Bone Joint Surg Series A","first-page":"378","article-title":"Motion of the shoulder complex during multiplanar humeral elevation","volume":"91","author":"Ludewig PM","year":"2009","unstructured":"Ludewig PM, Phadke V, Braman JP, Hassett DR, Cieminski CJ, Laprade RF. Motion of the shoulder complex during multiplanar humeral elevation. J Bone Joint Surg Series A. 2009;91(2):378\u2013389. doi:10.2106\/JBJS.G.01483"},{"issue":"2","key":"r19","series-title":"Clin Biomech","first-page":"184","article-title":"Scapulohumeral rhythm and associated spinal motion","volume":"23","author":"Crosbie J","year":"2008","unstructured":"Crosbie J, Kilbreath SL, Hollmann L, York S. Scapulohumeral rhythm and associated spinal motion. Clin Biomech. 2008;23(2):184\u2013192. doi:10.1016\/j.clinbiomech.2007.09.012"},{"key":"r20","series-title":"J Biomech","first-page":"138","article-title":"Scapulothoracic kinematic pattern in the shoulder pain and scapular dyskinesis: a principal component analysis approach","volume":"77","author":"Rossi DM","year":"2018","unstructured":"Rossi DM, Resende RA, da Fonseca ST, de Oliveira AS. Scapulothoracic kinematic pattern in the shoulder pain and scapular dyskinesis: a principal component analysis approach. J Biomech. 2018;77:138\u2013145. doi:10.1016\/j.jbiomech.2018.07.010"}],"container-title":["Journal of Sport Rehabilitation"],"original-title":[],"link":[{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jsr\/32\/8\/article-p926.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jsr\/32\/8\/article-p926.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jsr\/32\/8\/article-p926.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,2]],"date-time":"2023-11-02T15:42:39Z","timestamp":1698939759000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jsr\/32\/8\/article-p926.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,1]]},"references-count":20,"journal-issue":{"issue":"8"},"URL":"https:\/\/doi.org\/10.1123\/jsr.2023-0005","relation":{},"ISSN":["1056-6716","1543-3072"],"issn-type":[{"value":"1056-6716","type":"print"},{"value":"1543-3072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,1]]}}}