{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T01:25:21Z","timestamp":1787016321182,"version":"build-2736575974"},"reference-count":20,"publisher":"Human Kinetics","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,8,1]]},"abstract":"<jats:p>\n                    <jats:italic>\n                      <jats:bold>Context<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Running is a popular form of physical activity but can increase an individual\u2019s lower-extremity injury risk. Running gait analysis via inertial measurement units (IMUs) is a method for collecting important gait data that is related to developing lower-extremity injuries, such as increased load from low step rate (SR), and long stride length (SL). IMU data can be derived from both foot- and shank-placed IMUs, but foot-placed sensors (RunScribe IMUs) need validation against shank-placed sensors.\n                    <jats:italic>\n                      <jats:bold>Purpose<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Determine criterion validity of RunScribe foot-placed IMUs against MyoMotion shank-placed IMU for SR and SL.\n                    <jats:italic>\n                      <jats:bold>Design<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    cross-sectional laboratory study.\n                    <jats:italic>\n                      <jats:bold>Methods<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Nine participants (5 males, 4 females; age: 28.33 [5.78]; height: 1.75 [0.11]; mass: 74.06 [16.24]) volunteered for our study. Following a 5-minute warm-up, participants ran on a treadmill for 5\u00a0minutes at a self-selected speed. After \u223c2.5\u00a0minutes, MyoMotion data were collected for 10\u00a0seconds. The RunScribe IMUs collected data throughout the full duration of the run. Criterion validity of SR and SL between the foot- and shank-placed IMUs was determined using bivariate Pearson correlations, intraclass correlation coefficients (3,1), and Bland\u2013Altman plots with 95% limits of agreement analysis.\n                    <jats:italic>\n                      <jats:bold>Results<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    A very strong correlation for SR (\n                    <jats:italic>r<\/jats:italic>\n                    \u2009=\u2009.90, N\u2009=\u20099,\n                    <jats:italic>P<\/jats:italic>\n                    \u2009\u2264\u2009.001), and a strong correlation for SL (\n                    <jats:italic>r<\/jats:italic>\n                    \u2009=\u2009.80, N\u2009=\u20099,\n                    <jats:italic>P<\/jats:italic>\n                    \u2009&lt;\u2009.001) were found between the foot and shank-placed IMUs. Excellent reliability was found for SR (intraclass correlation coefficient\u2009=\u2009.91,\n                    <jats:italic>P<\/jats:italic>\n                    \u2009\u2264\u2009.001, 95% CI, .639\u2013.978), and good reliability was found for SL (intraclass correlation coefficient\u2009=\u2009.800,\n                    <jats:italic>P<\/jats:italic>\n                    \u2009=\u2009.003, 95% CI, .340\u2013.951) between the foot and shank-placed IMUs. The mean difference of SR and SL was \u22122.111 and \u22120.142, respectively, indicating good agreement between the foot and shank-placed IMUs.\n                    <jats:italic>\n                      <jats:bold>Conclusions<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Foot-placed RunScribe IMUs are a valid alternative for measuring SR and SL compared with shank-placed IMUs.\n                  <\/jats:p>","DOI":"10.1123\/jsr.2024-0258","type":"journal-article","created":{"date-parts":[[2025,3,20]],"date-time":"2025-03-20T19:57:18Z","timestamp":1742500638000},"page":"672-676","source":"Crossref","is-referenced-by-count":3,"title":["Foot-Placed Inertial Measurement Units Are Valid Against Shank-Placed Units When Measuring Temporospatial Running Variables"],"prefix":"10.1123","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8989-7042","authenticated-orcid":true,"given":"Madison S.","family":"Mach","sequence":"first","affiliation":[{"name":"School of Rehabilitation Sciences and Technology, University of Wisconsin-Milwaukee, Milwaukee, WI, USA"},{"name":"Keller Army Community Hospital, West Point, NY, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1794-1881","authenticated-orcid":true,"given":"Hayley","family":"Ericksen","sequence":"additional","affiliation":[{"name":"School of Kinesiology and Recreation, Illinois State University, Normal, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-4578-0411","authenticated-orcid":true,"given":"Erin","family":"Lally","sequence":"additional","affiliation":[{"name":"Department of Health and Human Performance, Texas State University, San Marcos, TX, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3308-3856","authenticated-orcid":true,"given":"Jennifer E.","family":"Earl-Boehm","sequence":"additional","affiliation":[{"name":"School of Rehabilitation Sciences and Technology, University of Wisconsin-Milwaukee, Milwaukee, WI, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"100","reference":[{"issue":"4","key":"r1","series-title":"Br J Sports Med","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1136\/bjsm.2006.033548","article-title":"Incidence and determinants of lower extremity running injuries in long distance runners: a systematic review","volume":"4","author":"van Gent RN","year":"2004","unstructured":"van Gent RN, Siem D, van Middelkoop M, et\u00a0al. Incidence and determinants of lower extremity running injuries in long distance runners: a systematic review. Br J Sports Med. 2004;4(4):220\u2013225. PubMed ID: 17473005 doi:10.1136\/bjsm.2006.033548"},{"issue":"9","key":"r2","series-title":"Med Sci Sports Exercise","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1249\/MSS.0b013e31817571ae","article-title":"External frontal plane loads may be associated with tibial stress fracture","volume":"40","author":"Creaby WM","year":"2008","unstructured":"Creaby WM, Dixon JS. External frontal plane loads may be associated with tibial stress fracture. Med Sci Sports Exercise. 2008;40(9):1669\u20131674. doi:10.1249\/MSS.0b013e31817571ae"},{"issue":"2","key":"r3","series-title":"Scand J Med Sci Sports","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1111\/sms.12413","article-title":"In-field gait retraining and mobile monitoring to address running biomechanics associated with tibial stress fracture","volume":"26","author":"Willy RW","year":"2016","unstructured":"Willy RW, Buchenic L, Rogacki K, Ackerman J, Schmidt A, Willson JD. In-field gait retraining and mobile monitoring to address running biomechanics associated with tibial stress fracture. Scand J Med Sci Sports. 2016;26(2):197\u2013205. PubMed ID: 25652871 doi:10.1111\/sms.12413"},{"key":"r4","series-title":"Front Sports Act Living","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2020.628348","article-title":"Factors associated with self-selected step rates between collegiate and high school cross country runners","volume":"2","author":"Luedke LE","year":"2021","unstructured":"Luedke LE, Rauh MJ. Factors associated with self-selected step rates between collegiate and high school cross country runners. Front Sports Act Living. 2021;2:628348. doi:10.3389\/fspor.2020.628348"},{"issue":"7","key":"r5","series-title":"Int J Exerc Sci","first-page":"1067","article-title":"Is the relationship between stride length, frequency, and velocity influenced by running on a treadmill or overground?","volume":"10","author":"Bailey J","year":"2017","unstructured":"Bailey J, Mata T, Mercer JA. Is the relationship between stride length, frequency, and velocity influenced by running on a treadmill or overground? Int J Exerc Sci. 2017;10(7):1067\u20131075. PubMed ID: 29170707"},{"issue":"4","key":"r6","series-title":"Sports Med","first-page":"785","article-title":"Is motorized treadmill running biomechanically comparable to overground running? A systematic review and meta-analysis of cross-over studies","volume":"50","author":"Van Hooren B","year":"2020","unstructured":"Van Hooren B, Fuller JT, Buckley JD, et\u00a0al. Is motorized treadmill running biomechanically comparable to overground running? A systematic review and meta-analysis of cross-over studies. Sports Med. 2020;50(4):785\u2013813. PubMed ID: 31802395"},{"issue":"3","key":"r7","series-title":"J Med Biochem","doi-asserted-by":"publisher","first-page":"225","DOI":"10.5937\/jomb0-24764","article-title":"Verification of quantitative analytical methods in medical laboratories","volume":"40","author":"Abdel GMT","year":"2021","unstructured":"Abdel GMT, El-Masry MI. Verification of quantitative analytical methods in medical laboratories. J Med Biochem. 2021;40(3):225\u2013236. PubMed ID: 34177366 doi:10.5937\/jomb0-24764"},{"issue":"4","key":"r8","series-title":"BMJ Open Sport Exerc Med","doi-asserted-by":"publisher","DOI":"10.1136\/bmjsem-2021-001293","article-title":"Sensor-based gait training to reduce contact time for runners with exercise-related lower leg pain: a randomised controlled trial","volume":"8","author":"DeJong Lempke AF","year":"2022","unstructured":"DeJong Lempke AF, Stephens SL, Fish PN, et\u00a0al. Sensor-based gait training to reduce contact time for runners with exercise-related lower leg pain: a randomised controlled trial. BMJ Open Sport Exerc Med. 2022;8(4):e001293. doi:10.1136\/bmjsem-2021-001293"},{"issue":"4","key":"r9","series-title":"J Sports Sci Med","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1136\/bjsm.2006.033548","article-title":"Lower extremity malalignments and anterior cruciate ligament injury history","volume":"3","author":"Hertel J","year":"2004","unstructured":"Hertel J, Dorfman JH, Braham RA, et\u00a0al. Lower extremity malalignments and anterior cruciate ligament injury history. J Sports Sci Med. 2004;3(4):220\u2013225.\u00a0PMID: 24624006 PMCID: PMC3938060 doi:10.1136\/bjsm.2006.033548"},{"issue":"14","key":"r10","series-title":"Am J Sports Med","doi-asserted-by":"publisher","first-page":"3406","DOI":"10.1177\/0363546519879693","article-title":"A 10% increase in step rate improves running kinematics and clinical outcomes in runners with patellofemoral pain at 4 weeks and 3 months","volume":"47","author":"Bramah C","year":"2019","unstructured":"Bramah C, Preece SJ, Gill N, Herrington L. A 10% increase in step rate improves running kinematics and clinical outcomes in runners with patellofemoral pain at 4 weeks and 3 months. Am J Sports Med. 2019;47(14):3406\u20133413. PubMed ID: 31657964 doi:10.1177\/0363546519879693"},{"issue":"5","key":"r11","series-title":"PLoS One","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0250965","article-title":"Effects of gait retraining with focus on impact versus gait retraining with focus on cadence on pain, function and lower limb kinematics in runners with patellofemoral pain: protocol of a randomized, blinded, parallel group trial with 6-month follow-up","volume":"16","author":"de Souza Junior JR","year":"2021","unstructured":"de Souza Junior JR, Reis Rabelo PH, Lemos TV, Esculier J-F, da Silva Carto JP, Chieregato Matheus JP. Effects of gait retraining with focus on impact versus gait retraining with focus on cadence on pain, function and lower limb kinematics in runners with patellofemoral pain: protocol of a randomized, blinded, parallel group trial with 6-month follow-up. PLoS One. 2021;16(5):e0250965. doi:10.1371\/journal.pone.0250965"},{"issue":"4","key":"r12","series-title":"J Sci Med Sport","first-page":"288","article-title":"Retraining running gait to reduce tibial loads with clinician or accelerometry guided feedback","volume":"19","author":"Creaby MW","year":"2016","unstructured":"Creaby MW, Smith MMF. Retraining running gait to reduce tibial loads with clinician or accelerometry guided feedback. J Sci Med Sport. 2016;19(4):288\u2013292. PubMed ID: 26026858"},{"key":"r13","series-title":"Gait Posture","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.gaitpost.2018.09.017","article-title":"The measurement of tibial acceleration in runners\u2014a review of the factors that can affect tibial acceleration during running and evidence-based guidelines for its use","volume":"67","author":"Sheerin KR","year":"2019","unstructured":"Sheerin KR, Reid D, Besier TF. The measurement of tibial acceleration in runners\u2014a review of the factors that can affect tibial acceleration during running and evidence-based guidelines for its use. Gait Posture. 2019;67:12\u201324. PubMed ID: 30248663 doi:10.1016\/j.gaitpost.2018.09.017"},{"key":"r14","series-title":"COSMIN Study Design Checklist for Patient-Reported Outcome Measurement Instruments","author":"Mokkink LB","year":"2019","unstructured":"Mokkink LB, Prinsen C, Patrick DL, et\u00a0al. COSMIN Study Design Checklist for Patient-Reported Outcome Measurement Instruments. COSMIN; 2019. https:\/\/www.cosmin.nl\/wp-content\/uploads\/COSMIN-study-designing-checklist_final.pdf"},{"issue":"2","key":"r15","series-title":"Digit Biomark","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1159\/000491645","article-title":"Validation of a wearable sensor for measuring running biomechanics","volume":"2","author":"Koldenhoven RM","year":"2018","unstructured":"Koldenhoven RM, Hertel J. Validation of a wearable sensor for measuring running biomechanics. Digit Biomark. 2018;2(2):74\u201378. PubMed ID: 32095758 PMCID: PMC7015375 doi:10.1159\/000491645"},{"issue":"3","key":"r16","series-title":"Malawi Med J","first-page":"69","article-title":"Statistics corner: a guide to appropriate use of correlation coefficient in medical research","volume":"24","author":"Mukaka MM","year":"2012","unstructured":"Mukaka MM. Statistics corner: a guide to appropriate use of correlation coefficient in medical research. Malawi Med J. 2012;24(3):69\u201371. PubMed ID: 23638278"},{"issue":"2","key":"r17","series-title":"J Chiropr Med","first-page":"155","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo TK","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155\u2013163. PubMed ID: 27330520"},{"issue":"5","key":"r18","series-title":"Sports Biomech","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1080\/14763141.2019.1579366","article-title":"Running biomechanics as measured by wearable sensors: effects of speed and surface","volume":"20","author":"Hollis CR","year":"2021","unstructured":"Hollis CR, Koldenhoven RM, Resch JE, Hertel J. Running biomechanics as measured by wearable sensors: effects of speed and surface. Sports Biomech. 2021;20(5):521\u2013531. PubMed ID: 30843475 doi:10.1080\/14763141.2019.1579366"},{"issue":"14","key":"r19","series-title":"IEEE Sens J.","doi-asserted-by":"publisher","first-page":"7783","DOI":"10.1109\/JSEN.2020.2982568","article-title":"Validating commercial wearable sensors for running gait parameters estimation","volume":"20","author":"de Fontenay BP","year":"2020","unstructured":"de Fontenay BP, Roy JS, Dubois B, Bouyer L, Esculier JF. Validating commercial wearable sensors for running gait parameters estimation. IEEE Sens J. 2020;20(14):7783\u20137791. doi:10.1109\/JSEN.2020.2982568"},{"key":"r20","series-title":"Front Sports Act Living","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2021.643385","article-title":"The effect of footwear, running speed, and location on the validity of two commercially available inertial measurement units during running","volume":"3","author":"Napier C","year":"2021","unstructured":"Napier C, Willy RW, Hannigan BC, McCann R, Menon C. The effect of footwear, running speed, and location on the validity of two commercially available inertial measurement units during running. Front Sports Act Living. 2021;3:643385. doi:10.3389\/fspor.2021.643385"}],"container-title":["Journal of Sport Rehabilitation"],"original-title":[],"link":[{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jsr\/34\/6\/article-p672.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jsr\/34\/6\/article-p672.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jsr\/34\/6\/article-p672.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,21]],"date-time":"2025-07-21T19:56:22Z","timestamp":1753127782000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jsr\/34\/6\/article-p672.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,1]]},"references-count":20,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.1123\/jsr.2024-0258","relation":{},"ISSN":["1056-6716","1543-3072"],"issn-type":[{"value":"1056-6716","type":"print"},{"value":"1543-3072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,1]]}}}