{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T23:32:49Z","timestamp":1793057569291,"version":"4.5.0"},"reference-count":22,"publisher":"Human Kinetics","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,11,1]]},"abstract":"<jats:p>\n                    <jats:italic>\n                      <jats:bold>Context<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    The athletic shoulder (ASH) test traditionally evaluates upper limb isometric strength in a prone position using a force platform. However, this position may lack functional relevance, and the force platforms are not portable. A functional electromechanical dynamometer may provide a potentially valid, reliable, portable, and standardized seated alternative.\n                    <jats:italic>\n                      <jats:bold>Design<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Randomized, repeated-measures design to assess the between-session reliability and concurrent validity of the Modified Seated ASH Test using an electromechanical dynamometer compared with the prone ASH test using a force platform.\n                    <jats:italic>\n                      <jats:bold>Methods<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    Thirty-four active university students (15 males, 19 females; 19.73 [3.68]\u00a0years) completed ASH assessments using a force platform (prone) and an electromechanical dynamometer (seated). We evaluated between-session reliability using intraclass correlation coefficients and coefficients of variation and concurrent validity using Pearson correlations (\n                    <jats:italic>r<\/jats:italic>\n                    ) and Bland\u2013Altman analyses.\n                    <jats:italic>\n                      <jats:bold>Results<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    The electromechanical dynamometer demonstrated excellent reliability across the 180\u00b0 (I), 135\u00b0 (Y), and 90\u00b0 (T) positions (intraclass correlation coefficient\u2009=\u2009.91\u2013.97, coefficients of variation\u2009=\u20097.25%\u201311.33%). The force platform also showed good to excellent reliability but with higher variability (intraclass correlation coefficient\u2009=\u2009.83\u2013.91, coefficients of variation\u2009=\u200912.43%\u201315.89%). Electromechanical dynamometer and force platform forces correlated strongly across\u00a0positions (\n                    <jats:italic>r<\/jats:italic>\n                    \u2009=\u2009.77\u2013.87,\n                    <jats:italic>P<\/jats:italic>\n                    \u2009&lt;\u2009.001). However, Bland\u2013Altman analyses revealed the electromechanical dynamometer yielded systematically higher forces (bias\u2009=\u200918\u201328\u00a0N) with nontrivial limits of agreement, indicating scores differ meaningfully between devices.\n                    <jats:italic>\n                      <jats:bold>Conclusions<\/jats:bold>\n                      :\n                    <\/jats:italic>\n                    The Modified Seated ASH test, using an electromechanical dynamometer, has good to excellent reliability for assessing upper limb isometric strength and is strongly associated with the traditional force platform-based ASH test. The presence of systematic bias and nontrivial limits of agreement indicates that electromechanical dynamometer- and force platform-derived forces should not be considered interchangeable for absolute strength quantification.\n                  <\/jats:p>","DOI":"10.1123\/jsr.2025-0074","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T04:12:27Z","timestamp":1779941547000},"page":"695-701","source":"Crossref","is-referenced-by-count":0,"title":["Validity and Reliability of a Modified Seated Athletic Shoulder Test Using a Functional Electromechanical Dynamometer"],"prefix":"10.1123","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9006-8516","authenticated-orcid":true,"given":"Ignacio J.","family":"Chirosa-R\u00edos","sequence":"first","affiliation":[{"name":"Department of Physical Education and Sport, Faculty of Sports Science, University of Granada, Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0077-6813","authenticated-orcid":true,"given":"Dario","family":"Mart\u00ednez-Garc\u00eda","sequence":"additional","affiliation":[{"name":"Department of Physical Education and Sport, Faculty of Sports Science, University of Granada, Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1008-176X","authenticated-orcid":true,"given":"Luis J.","family":"Chirosa-R\u00edos","sequence":"additional","affiliation":[{"name":"Department of Physical Education and Sport, Faculty of Sports Science, University of Granada, Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1829-0734","authenticated-orcid":true,"given":"Gustavo","family":"Garc\u00eda-Buend\u00eda","sequence":"additional","affiliation":[{"name":"Department of Physical Education and Sport, Faculty of Sports Science, University of Granada, Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2718-7253","authenticated-orcid":true,"given":"Raquel","family":"Escobar-Molina","sequence":"additional","affiliation":[{"name":"Department of Physical Education and Sport, Faculty of Sports Science, University of Granada, Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-5683-522X","authenticated-orcid":true,"given":"Jesus","family":"Jim\u00e9nez-Mart\u00ednez","sequence":"additional","affiliation":[{"name":"Department of Physical Education and Sport, Faculty of Sports Science, University of Granada, Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"100","reference":[{"issue":"9","key":"r1","series-title":"Br J Sports Med","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1136\/bjsports-2018-099457","article-title":"Force awakens: a new hope for athletic shoulder strength testing","volume":"53","author":"Ashworth B","year":"2019","unstructured":"Ashworth B, Cohen DD. Force awakens: a new hope for athletic shoulder strength testing. Br J Sports Med. 2019;53(9):524\u2013524. PubMed ID: 30413428 doi:10.1136\/bjsports-2018-099457"},{"issue":"1","key":"r2","series-title":"BMJ Open Sport Exerc Med","doi-asserted-by":"publisher","DOI":"10.1136\/bmjsem-2018-000365","article-title":"The Athletic Shoulder (ASH) test: reliability of a novel upper body isometric strength test in elite rugby players","volume":"4","author":"Ashworth B","year":"2018","unstructured":"Ashworth B, Hogben P, Singh N, Tulloch L, Cohen DD. The Athletic Shoulder (ASH) test: reliability of a novel upper body isometric strength test in elite rugby players. BMJ Open Sport Exerc Med. 2018;4(1):e000365. doi:10.1136\/bmjsem-2018-000365"},{"issue":"suppl 1","key":"r3","series-title":"Shoulder Elbow","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1177\/17585732221145558","article-title":"Reliability of two devices for shoulder strength assessment: Wii Fit balance board and hand-held dynamometer","volume":"16","author":"Intelangelo L","year":"2024","unstructured":"Intelangelo L, Elias G, Lassaga I, Bustos C, Jerez-Mayorga D. Reliability of two devices for shoulder strength assessment: Wii Fit balance board and hand-held dynamometer. Shoulder Elbow. 2024;16(suppl 1):110\u2013118. PubMed ID: 38425742 doi:10.1177\/17585732221145558"},{"issue":"5","key":"r4","series-title":"J Back Musculoskelet Rehabil","doi-asserted-by":"publisher","first-page":"937","DOI":"10.3233\/BMR-210261","article-title":"Reliability of trunk strength measurements with an isokinetic dynamometer in non-specific low back pain patients: a systematic review","volume":"35","author":"Reyes-Ferrada W","year":"2022","unstructured":"Reyes-Ferrada W, Chirosa-Rios L, Martinez-Garcia D, Rodr\u00edguez-Perea \u00c1, Jerez-Mayorga D. Reliability of trunk strength measurements with an isokinetic dynamometer in non-specific low back pain patients: a systematic review. J Back Musculoskelet Rehabil. 2022;35(5):937\u2013948. PubMed ID: 35213350 doi:10.3233\/BMR-210261"},{"issue":"11","key":"r5","series-title":"Sensors","doi-asserted-by":"publisher","DOI":"10.3390\/s24113568","article-title":"Reliability of dynamic shoulder strength test battery using multi-joint isokinetic device","volume":"24","author":"Garc\u00eda-Buend\u00eda G","year":"2024","unstructured":"Garc\u00eda-Buend\u00eda G, Rodr\u00edguez-Perea \u00c1, Chirosa-R\u00edos I, Chirosa-R\u00edos LJ, Mart\u00ednez-Garc\u00eda D. Reliability of dynamic shoulder strength test battery using multi-joint isokinetic device. Sensors. 2024;24(11):3568. doi:10.3390\/s24113568"},{"issue":"3","key":"r6","series-title":"Proc Inst Mech Eng P J Sport Eng Technol","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1177\/1754337120984883","article-title":"Reliability and concurrent validity of a functional electromechanical dynamometer device for the assessment of movement velocity","volume":"235","author":"Rodriguez-Perea \u00c1","year":"2021","unstructured":"Rodriguez-Perea \u00c1, Jerez-Mayorga D, Garc\u00eda-Ramos A, Mart\u00ednez-Garc\u00eda D, Chirosa R\u00edos LJ. Reliability and concurrent validity of a functional electromechanical dynamometer device for the assessment of movement velocity. Proc Inst Mech Eng P J Sport Eng Technol. 2021;235(3):176\u2013181. doi:10.1177\/1754337120984883"},{"issue":"1","key":"r7","series-title":"Arch Orofac Sci","first-page":"1","article-title":"A simplified guide to determination of sample size requirements for estimating the value of intraclass correlation coefficient: a review","volume":"12","author":"Bujang MA","year":"2017","unstructured":"Bujang MA, Baharum N. A simplified guide to determination of sample size requirements for estimating the value of intraclass correlation coefficient: a review. Arch Orofac Sci. 2017;12(1):1\u201311."},{"issue":"3","key":"r8","series-title":"Proc Inst Mech Eng P J Sport Eng Technol","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1177\/17543371211030180","article-title":"Concurrent validity and reliability of a functional electromechanical dynamometer to assess isometric mid-thigh pull performance","volume":"237","author":"Baena-Raya A","year":"2023","unstructured":"Baena-Raya A, D\u00edez-Fern\u00e1ndez DM, Garc\u00eda-Ramos A, Soriano-Maldonado A, Rodr\u00edguez-P\u00e9rez MA. Concurrent validity and reliability of a functional electromechanical dynamometer to assess isometric mid-thigh pull performance. Proc Inst Mech Eng P J Sport Eng Technol. 2023;237(3):197\u2013204. doi:10.1177\/17543371211030180"},{"issue":"6","key":"r9","series-title":"Pain Manag Nurs","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1016\/j.pmn.2020.04.001","article-title":"A Comparison of the Pain Assessment Checklist for Seniors with Limited Ability to Communicate (PACSLAC) and Pain Assessment in Advanced Dementia Scale (PAINAD)","volume":"21","author":"Natavio T","year":"2020","unstructured":"Natavio T, McQuillen E, Dietrich MS, et\u00a0al. A Comparison of the Pain Assessment Checklist for Seniors with Limited Ability to Communicate (PACSLAC) and Pain Assessment in Advanced Dementia Scale (PAINAD). Pain Manag Nurs. 2020;21(6):502\u2013509. PubMed ID: 32475696 doi:10.1016\/j.pmn.2020.04.001"},{"issue":"8476","key":"r10","series-title":"Lancet","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Martin Bland J","year":"1986","unstructured":"Martin Bland J, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;327(8476):307\u2013310. doi:10.1016\/S0140-6736(86)90837-8"},{"issue":"2","key":"r11","series-title":"J Chiropr Med","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo TK","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155\u2013163. PubMed ID: 27330520 doi:10.1016\/j.jcm.2016.02.012"},{"issue":"2","key":"r12","series-title":"Int J Sports Physiol Perform","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1123\/ijspp.3.2.131","article-title":"Reliability of measures obtained during single and repeated countermovement jumps","volume":"3","author":"Cormack SJ","year":"2008","unstructured":"Cormack SJ, Newton RU, McGuigan MR, Doyle TLA. Reliability of measures obtained during single and repeated countermovement jumps. Int J Sports Physiol Perform. 2008;3(2):131\u2013144. PubMed ID: 19208922 doi:10.1123\/ijspp.3.2.131"},{"key":"r13","series-title":"Sportscience","first-page":"36","article-title":"Spreadsheets for analysis of validity and reliability","volume":"19","author":"Hopkins WG","year":"2015","unstructured":"Hopkins WG. Spreadsheets for analysis of validity and reliability. Sportscience. 2015;19:36\u201344."},{"key":"r14","series-title":"Phys Ther Sport","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.ptsp.2022.08.003","article-title":"The modified-athletic shoulder test: reliability and validity of a new on-field assessment tool","volume":"58","author":"Tooth C","year":"2022","unstructured":"Tooth C, Forthomme B, Croisier JL, Gofflot A, Bornheim S, Schwartz C. The modified-athletic shoulder test: reliability and validity of a new on-field assessment tool. Phys Ther Sport. 2022;58:8\u201315. PubMed ID: 36088802 doi:10.1016\/j.ptsp.2022.08.003"},{"issue":"2","key":"r15","series-title":"J Sci Med Sport","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.jsams.2016.06.008","article-title":"The reliability of a maximal isometric hip strength and simultaneous surface EMG screening protocol in elite, junior rugby league athletes","volume":"20","author":"Charlton PC","year":"2017","unstructured":"Charlton PC, Mentiplay BF, Grimaldi A, Pua YH, Clark RA. The reliability of a maximal isometric hip strength and simultaneous surface EMG screening protocol in elite, junior rugby league athletes. J Sci Med Sport. 2017;20(2):139\u2013145. PubMed ID: 27473653 doi:10.1016\/j.jsams.2016.06.008"},{"issue":"4","key":"r16","series-title":"Biology","doi-asserted-by":"publisher","DOI":"10.3390\/biology11040577","article-title":"Reliability and Validity of the Athletic Shoulder (ASH) test performed using portable isometric-based strength training device","volume":"11","author":"Kr\u00f3likowska A","year":"2022","unstructured":"Kr\u00f3likowska A, Mika A, Plaskota B, et\u00a0al. Reliability and Validity of the Athletic Shoulder (ASH) test performed using portable isometric-based strength training device. Biology. 2022;11(4):577. doi:10.3390\/biology11040577"},{"issue":"4","key":"r17","series-title":"J Athl Train","doi-asserted-by":"publisher","first-page":"350","DOI":"10.4085\/1062-6050-471-18","article-title":"The self-assessment corner for shoulder strength: reliability, validity, and correlations with upper extremity physical performance tests","volume":"55","author":"Decleve P","year":"2020","unstructured":"Decleve P, Van Cant J, De Buck E, Van Doren J, Verkouille J, Cools AM. The self-assessment corner for shoulder strength: reliability, validity, and correlations with upper extremity physical performance tests. J Athl Train. 2020;55(4):350\u2013358. PubMed ID: 32053404 doi:10.4085\/1062-6050-471-18"},{"issue":"3","key":"r18","series-title":"J Sport Rehabil","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1123\/jsr.20.3.367","article-title":"Reliability of isokinetic assessment of shoulder-rotator strength: a systematic review of the effect of position","volume":"20","author":"Edouard P","year":"2011","unstructured":"Edouard P, Samozino P, Julia M, et\u00a0al. Reliability of isokinetic assessment of shoulder-rotator strength: a systematic review of the effect of position. J Sport Rehabil. 2011;20(3):367\u2013383. PubMed ID: 21828388 doi:10.1123\/jsr.20.3.367"},{"issue":"17","key":"r19","series-title":"Int J Environ Res Public Health","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph18179251","article-title":"Scapular retraction under adduction load: an alternative to overhead exercises to activate infraspinatus, upper, and lower trapezius in subjects with and without shoulder pain","volume":"18","author":"dos Santos JJ","year":"2021","unstructured":"dos Santos JJ, Nagy RO, Souza MA, et\u00a0al. Scapular retraction under adduction load: an alternative to overhead exercises to activate infraspinatus, upper, and lower trapezius in subjects with and without shoulder pain. Int J Environ Res Public Health. 2021;18(17):9251. doi:10.3390\/ijerph18179251"},{"key":"r20","series-title":"Hum Mov Sci","doi-asserted-by":"publisher","DOI":"10.1016\/j.humov.2019.102567","article-title":"Comparative study of the differences in shoulder muscle activation according to arm rotation angle","volume":"69","author":"Ijiri T","year":"2020","unstructured":"Ijiri T, Urabe Y, Maeda N, Sasadai J, Suzuki T. Comparative study of the differences in shoulder muscle activation according to arm rotation angle. Hum Mov Sci. 2020;69:102567. doi:10.1016\/j.humov.2019.102567"},{"issue":"2","key":"r21","series-title":"J Sport Rehabil","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1123\/jsr.2021-0221","article-title":"Shoulder strength and upper body field performance tests in young female handball and volleyball athletes: are there differences between sports?","volume":"31","author":"Saccol MF","year":"2022","unstructured":"Saccol MF, Zanca GG, Machado RO, et\u00a0al. Shoulder strength and upper body field performance tests in young female handball and volleyball athletes: are there differences between sports? J Sport Rehabil. 2022;31(2):191\u2013198. PubMed ID: 34856534 doi:10.1123\/jsr.2021-0221"},{"issue":"5","key":"r22","series-title":"Braz J Phys Ther","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1590\/bjpt-rbf.2014.0109","article-title":"Prevention of shoulder injuries in overhead athletes: a science-based approach","volume":"19","author":"Cools AM","year":"2015","unstructured":"Cools AM, Johansson FR, Borms D, Maenhout A. Prevention of shoulder injuries in overhead athletes: a science-based approach. Braz J Phys Ther. 2015;19(5):331\u2013339. PubMed ID: 26537804 doi:10.1590\/bjpt-rbf.2014.0109"}],"container-title":["Journal of Sport Rehabilitation"],"original-title":[],"link":[{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jsr\/35\/8\/article-p695.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jsr\/35\/8\/article-p695.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.humankinetics.com\/downloadpdf\/journals\/jsr\/35\/8\/article-p695.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T22:51:05Z","timestamp":1793055065000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.humankinetics.com\/view\/journals\/jsr\/35\/8\/article-p695.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11,1]]},"references-count":22,"journal-issue":{"issue":"8"},"URL":"https:\/\/doi.org\/10.1123\/jsr.2025-0074","relation":{},"ISSN":["1056-6716","1543-3072"],"issn-type":[{"value":"1056-6716","type":"print"},{"value":"1543-3072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,11,1]]}}}