{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T06:56:54Z","timestamp":1792133814443,"version":"4.4.0"},"reference-count":71,"publisher":"American Association for the Advancement of Science (AAAS)","issue":"40","content-domain":{"domain":["www.science.org"],"crossmark-restriction":true},"short-container-title":["Sci. Adv."],"published-print":{"date-parts":[[2025,10,3]]},"abstract":"<jats:p>Endovascular aneurysm repair, a treatment for abdominal aortic aneurysms, carries the risk of recurrence due to endoleaks following stent graft implantation. Since these leaks do not present with specific symptoms, regular follow-up is necessary; however, now, only imaging-based monitoring is available. This study proposes an ultrathin flexible sensor inserted endovascularly with a stent to detect type I endoleaks, which pose the highest rupture risk. A coplanar capacitive sensor was attached to the stent graft using a specially developed flexible thermal adhesive to monitor blood leakage, without compromising the stent graft\u2019s function. It seamlessly folds and unfolds with the stent, allowing implantation through catheter-based procedures. Experimental validation confirmed that the sensor does not induce blood leakage and demonstrated long-term stability and functionality under vascular and dynamic conditions. This technology enables wireless monitoring of endoleak status, facilitates timely intervention, and improves postoperative outcomes by reducing the risk of recurrent aneurysms.<\/jats:p>","DOI":"10.1126\/sciadv.ady6148","type":"journal-article","created":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T17:58:40Z","timestamp":1759341520000},"update-policy":"https:\/\/doi.org\/10.34133\/aaas_crossmark","source":"Crossref","is-referenced-by-count":8,"title":["A wireless, implantable sensor for continuous monitoring of blood leakage after endovascular aneurysm repair"],"prefix":"10.1126","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-8206-0704","authenticated-orcid":true,"given":"Sun Young","family":"Park","sequence":"first","affiliation":[{"name":"Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-7932-0793","authenticated-orcid":true,"given":"Soo Hyun","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Artificial Intelligence Semiconductor Engineering, Hanyang University, Seoul 04763, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-9450-8132","authenticated-orcid":true,"given":"Unseong","family":"Baik","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, POSTECH, Pohang 37673, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seung Jae","family":"Huh","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Hanyang University, Seoul 04763, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-0092-5307","authenticated-orcid":true,"given":"Raudel","family":"Avila","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2502-2807","authenticated-orcid":true,"given":"Hyeon Ho","family":"Shin","sequence":"additional","affiliation":[{"name":"Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyoungsuk","family":"Yoo","sequence":"additional","affiliation":[{"name":"Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9036-155X","authenticated-orcid":true,"given":"Heungsoo","family":"Shin","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Hanyang University, Seoul 04763, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9933-1931","authenticated-orcid":true,"given":"Jin-Tae","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, POSTECH, Pohang 37673, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7203-7425","authenticated-orcid":true,"given":"Young-Hyo","family":"Lim","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, College of Medicine, Hanyang University, Seoul 04763, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1754-2602","authenticated-orcid":true,"given":"Yei Hwan","family":"Jung","sequence":"additional","affiliation":[{"name":"Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea."},{"name":"Department of Artificial Intelligence Semiconductor Engineering, Hanyang University, Seoul 04763, Republic of Korea."},{"name":"Institute of Nano Science and Technology, Hanyang University, Seoul 04763, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"221","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02015271"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMc1007807"},{"key":"e_1_3_2_4_2","first-page":"153","article-title":"Endovascular abdominal aortic aneurysm repair","volume":"9","author":"Sharma A.","year":"2020","unstructured":"A. Sharma, P. Sethi, K. Gupta, Endovascular abdominal aortic aneurysm repair. Interv. Cardiol. Clin. 9, 153\u2013168 (2020).","journal-title":"Interv. Cardiol. Clin."},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(04)16979-1"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2009.1426"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa042002"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/152660289600300119"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1583\/1074-6218(1997)004<0152:EAACOE>2.0.CO;2"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2014.08.002"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1053\/ejvs.2000.1341"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10016-004-0100-z"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1177\/152660289800500212"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2001.119038"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2016.01.027"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvscit.2023.101165"},{"key":"e_1_3_2_17_2","first-page":"53","article-title":"Endoleak after endovascular aortic repair: Classification, diagnosis and management following endovascular thoracic and abdominal aortic repair","volume":"51","author":"Cao P.","year":"2010","unstructured":"P. Cao, P. De Rango, F. Verzini, G. Parlani, Endoleak after endovascular aortic repair: Classification, diagnosis and management following endovascular thoracic and abdominal aortic repair. J. Card. Surg. 51, 53\u201369 (2010).","journal-title":"J. Card. Surg."},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.semvascsurg.2004.09.003"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.semvascsurg.2004.03.003"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2433051649"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.4174\/jkss.2012.82.1.59"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.13.11736"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2017.10.044"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2021.06.147"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.014902"},{"key":"e_1_3_2_26_2","first-page":"e223","article-title":"2022 ACC\/AHA guideline for the diagnosis and management of aortic disease: A report of the American Heart Association\/American College of Cardiology Joint Committee on Clinical Practice Guidelines","volume":"80","author":"Writing Committee Members","year":"2022","unstructured":"Writing Committee Members, E. M. Isselbacher, O. Preventza, J. H. Black III, J. G. Augoustides, A. W. Beck, M. A. Bolen, A. C. Braverman, B. E. Bray, M. M. Brown-Zimmerman, E. P. Chen, T. J. Collins, A. De Anda Jr., C. L. Fanola, L. N. Girardi, C. W. Hicks, D. S. Hui, W. S. Jones, V. Kalahasti, K. M. Kim, D. M. Milewicz, G. S. Oderich, L. Ogbechie, S. B. Promes, E. G. Ross, M. L. Schermerhorn, S. S. Times, E. E. Tseng, G. J. Wang, Y. J. Woo, 2022 ACC\/AHA guideline for the diagnosis and management of aortic disease: A report of the American Heart Association\/American College of Cardiology Joint Committee on Clinical Practice Guidelines. J. Am. Coll. Cardiol. 80, e223\u2013e393 (2022).","journal-title":"J. Am. Coll. Cardiol."},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.avsg.2021.06.013"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.avsg.2015.08.011"},{"key":"e_1_3_2_29_2","doi-asserted-by":"crossref","unstructured":"L. K. Baxter Capacitive Sensors: Design and Applications (Wiley 1996).","DOI":"10.1109\/9780470544228"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3735\/19\/11\/002"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2009.2032966"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1177\/152660280301000211"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0025-6196(11)63997-9"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2009.07.002"},{"key":"e_1_3_2_35_2","first-page":"287","article-title":"Sizes of endografts for endovascular aortic repair: Do few fit most?","volume":"90","author":"Mazzaccaro D.","year":"2019","unstructured":"D. Mazzaccaro, L. Muzzarelli, A. Modafferi, G. Nano, Sizes of endografts for endovascular aortic repair: Do few fit most? Ann. Ital. Chir. 90, 287\u2013291 (2019).","journal-title":"Ann. Ital. Chir."},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.4244\/EIJV6I6A125"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2021.10.022"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2014.12.003"},{"key":"e_1_3_2_39_2","first-page":"06008","article-title":"Numerical simulation of Nitinol peripheral stents: From laser-cutting to deployment in a patient specific anatomy","volume":"2009","author":"Conti M.","year":"2009","unstructured":"M. Conti, F. Auricchio, M. De Beule, B. Verhegghe, Numerical simulation of Nitinol peripheral stents: From laser-cutting to deployment in a patient specific anatomy. ESOMAT 2009, 06008 (2009).","journal-title":"ESOMAT"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2009.07.001"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2014.08.010"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1039\/c3sm51360b"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9797(81)90031-X"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/19\/7\/075702"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1039\/C6SM00154H"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10047-015-0847-8"},{"key":"e_1_3_2_47_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.radcr.2023.10.062"},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1007\/s002700010042"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.53.1.96"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.3390\/ijms25105249"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijadhadh.2011.11.009"},{"key":"e_1_3_2_52_2","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRev.17.273"},{"key":"e_1_3_2_53_2","doi-asserted-by":"crossref","unstructured":"Y. Yuan T. R. Lee \u201cContact Angle and Wetting Properties\u201d in Surface Science Techniques (Springer 2013) pp. 3\u201334.","DOI":"10.1007\/978-3-642-34243-1_1"},{"key":"e_1_3_2_54_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.0602740103"},{"key":"e_1_3_2_55_2","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.201300220"},{"key":"e_1_3_2_56_2","doi-asserted-by":"publisher","DOI":"10.1122\/1.549276"},{"key":"e_1_3_2_57_2","first-page":"129","article-title":"Mechanical and optical characteristics of transparent stretchable hybrid substrate using PDMS and ecoflex material","volume":"25","author":"Lee W. J.","year":"2018","unstructured":"W. J. Lee, S. Y. Park, H. J. Nam, S. H. Choa, Mechanical and optical characteristics of transparent stretchable hybrid substrate using PDMS and ecoflex material. J. Microelectron. Packag. Soc. 25, 129\u2013135 (2018).","journal-title":"J. Microelectron. Packag. Soc."},{"key":"e_1_3_2_58_2","doi-asserted-by":"crossref","unstructured":"C. G. Caro T. J. Pedley R. C. Schroter W. A. Seed The Mechanics of the Circulation (Cambridge Univ. Press ed. 2 2012).","DOI":"10.1017\/CBO9781139013406"},{"key":"e_1_3_2_59_2","doi-asserted-by":"publisher","DOI":"10.1002\/adfm.201808247"},{"key":"e_1_3_2_60_2","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2016.2602298"},{"key":"e_1_3_2_61_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(98)80209-X"},{"key":"e_1_3_2_62_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1051-0443(07)61918-6"},{"key":"e_1_3_2_63_2","doi-asserted-by":"crossref","unstructured":"J. P. K. Sampath A. Alphones H. Shimasaki \u201cCoil design guidelines for high efficiency of wireless power transfer (WPT)\u201d in 2016 IEEE Region 10 Conference (TENCON) (IEEE 2016) pp. 726\u2013729.","DOI":"10.1109\/TENCON.2016.7848098"},{"key":"e_1_3_2_64_2","doi-asserted-by":"crossref","unstructured":"B. H. Waters B. J. Mahoney G. Lee J. R. Smith \u201cOptimal coil size ratios for wireless power transfer applications\u201d in 2014 IEEE International Symposium on Circuits and Systems (ISCAS) (IEEE 2014) pp. 2045\u20132048.","DOI":"10.1109\/ISCAS.2014.6865567"},{"key":"e_1_3_2_65_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02457921"},{"key":"e_1_3_2_66_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.1987.326088"},{"key":"e_1_3_2_67_2","doi-asserted-by":"crossref","unstructured":"J. O. Mur-Miranda G. Fanti Y. Feng K. Omanakuttan R. Ongie A. Setjoadi N. Sharpe \u201cWireless power transfer using weakly coupled magnetostatic resonators\u201d in 2010 IEEE Energy Conversion Congress and Exposition (IEEE 2010) pp. 4179\u20134186.","DOI":"10.1109\/ECCE.2010.5617728"},{"key":"e_1_3_2_68_2","doi-asserted-by":"publisher","DOI":"10.3109\/02656738909140497"},{"key":"e_1_3_2_69_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.avsg.2020.08.126"},{"key":"e_1_3_2_70_2","unstructured":"M. W. Siebert P. S. Fodor Newtonian and non-Newtonian blood flow over a backward-facing step\u2014A case study paper presented at the COMSOL Conference 2009 Boston MA 2009."},{"key":"e_1_3_2_71_2","unstructured":"F. M. White Fluid Mechanics (McGraw-Hill ed. 5 2003) vol. 3. McGraw-Hill series in mechanical engineering."},{"key":"e_1_3_2_72_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11095-011-0424-7"}],"container-title":["Science Advances"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.science.org\/doi\/pdf\/10.1126\/sciadv.ady6148","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T18:00:37Z","timestamp":1759341637000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.science.org\/doi\/10.1126\/sciadv.ady6148"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,3]]},"references-count":71,"journal-issue":{"issue":"40","published-print":{"date-parts":[[2025,10,3]]}},"alternative-id":["10.1126\/sciadv.ady6148"],"URL":"https:\/\/doi.org\/10.1126\/sciadv.ady6148","relation":{},"ISSN":["2375-2548"],"issn-type":[{"value":"2375-2548","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,3]]},"assertion":[{"value":"2025-04-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-05","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-01","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"eady6148"}}