{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T00:20:07Z","timestamp":1773879607005,"version":"3.50.1"},"reference-count":43,"publisher":"American Association for the Advancement of Science (AAAS)","issue":"12","funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["PHS R01GM136654"],"award-info":[{"award-number":["PHS R01GM136654"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100013967","name":"Robertson Research International Limited","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100013967","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.science.org"],"crossmark-restriction":true},"short-container-title":["Sci. Adv."],"published-print":{"date-parts":[[2026,3,20]]},"abstract":"<jats:p>\n                    Parallelization has revolutionized computing and DNA sequencing but remains largely unexploited in mass spectrometry (MS), which typically analyzes ions sequentially. Inspired by nuclear cytoplasmic transport, where diffusion governs transport to multiple gated channels (nuclear pore complexes), we introduce an ion trap (MultiQ-IT) that enables massively parallel MS. The device comprises a cubic array of small quadrupoles forming multiple ion entry and exit ports, allowing &gt;10\n                    <jats:sup>9<\/jats:sup>\n                    ions to be cooled, confined, and manipulated simultaneously. This architecture enables selective depletion of singly charged ions, thereby enhancing signal-to-noise ratios and expanding the effective dynamic range. The trap also functions as a parallel ion splitter, transmitting ions into multiple mass\/charge ratio\u2013specific beams. We demonstrate scalable ion throughput, real-time charge discrimination, and parallel beam separation, suggesting a path toward truly parallel MS. Our results establish a conceptual framework for next-generation, high-throughput proteomic and metabolomic analyses.\n                  <\/jats:p>","DOI":"10.1126\/sciadv.aec7048","type":"journal-article","created":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T17:59:43Z","timestamp":1773856783000},"update-policy":"https:\/\/doi.org\/10.34133\/aaas_crossmark","source":"Crossref","is-referenced-by-count":0,"title":["A nature-inspired ion trap for parallel manipulation of ions on a massive scale"],"prefix":"10.1126","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-7774-2334","authenticated-orcid":true,"given":"Andrew N.","family":"Krutchinsky","sequence":"first","affiliation":[{"name":"The Rockefeller University, 1230 York Avenue, New York, NY 10065, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3524-557X","authenticated-orcid":true,"given":"Brian T.","family":"Chait","sequence":"additional","affiliation":[{"name":"The Rockefeller University, 1230 York Avenue, New York, NY 10065, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"221","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1021\/cr3003533"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1038\/nature19949"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1021\/acs.analchem.3c02856"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.15252\/msb.202110798"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41592-023-01830-1"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1145\/42411.42415"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13361-016-1573-z"},{"key":"e_1_3_2_9_2","unstructured":"A. A. Makarov S. Horning S. R. Horning Parallel mass analysis. US Patent 7 985 950 B2 (2011)."},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1021\/ac000109p"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1021\/ac000377n"},{"key":"e_1_3_2_12_2","unstructured":"A. N. Krutchinsky V. Sherman H. Cohen B. T. Chait Multi-pole ion trap for mass spectrometry-1. US Patent 8 637 817 B1 (2014)."},{"key":"e_1_3_2_13_2","unstructured":"A. N. Krutchinsky V. Sherman H. Cohen B. T. Chait Multi-pole ion trap for mass spectrometry-2. US Patent 8 866 076 B2 (2014)."},{"key":"e_1_3_2_14_2","unstructured":"A. N. Krutchinsky V. Sherman H. Cohen B. T. Chait Multi-pole ion trap for mass spectrometry-3. US Patent 9 129 789 B2 (2015)."},{"key":"e_1_3_2_15_2","unstructured":"A. N. Krutchinsky V. Sherman H. Cohen B. T. Chait Multi-pole ion trap for mass spectrometry-4. US Patent 9 299 550 B2 (2016)."},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1083\/jcb.148.4.635"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.tcb.2003.10.007"},{"key":"e_1_3_2_18_2","unstructured":"J. Franzen M. Schubert Method and device for the reflection of charged particles on surfaces. US Patent 5 572 035 A (1996)."},{"key":"e_1_3_2_19_2","unstructured":"C. M. Whitehouse D. G. Welkie L. Cousins RF surfaces and RF ion guides. US Patent 7 365 317 B2 (2008)."},{"key":"e_1_3_2_20_2","unstructured":"R. E. March J. F. J. Todd Practical Aspects of Ion Trap Mass Spectrometry Volume 1: Fundamentals of Ion Trap Mass Spectrometry T. Cairns Ed. CRC Series Modern Mass Spectrometry (CRC Press 1995)."},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0020-7381(76)80101-5"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0020-7381(72)80041-X"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1044-0305(03)00446-X"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.1290040305"},{"key":"e_1_3_2_25_2","doi-asserted-by":"crossref","unstructured":"S. K. Chowdhury V. Katta B. T. Chait Electrospray ionization mass spectrometer with new features. US Patent 4 977 320 (1990).","DOI":"10.1002\/rcm.1290040305"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13361-013-0622-0"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13361-015-1306-8"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1021\/ac4001223"},{"key":"e_1_3_2_29_2","first-page":"1","article-title":"Inhomogenous RF-fields - A versatile tool for the study of processes with slow ions","volume":"82","author":"Gerlich D.","year":"1992","unstructured":"D. Gerlich, Inhomogenous RF-fields - A versatile tool for the study of processes with slow ions. Adv. Chem. Phys. 82, 1\u2013176 (1992).","journal-title":"Adv. Chem. Phys."},{"key":"e_1_3_2_30_2","unstructured":"J. W. Hager Method of mass spectrometry to enhance seperation of ions with different charges. US Patent 2 004 183 005 A1 (2004)."},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1044-0305(03)00535-X"},{"key":"e_1_3_2_32_2","unstructured":"H. C. Berg Random Walks in Biology: New and Expanded Edition (Princeton Univ. Press 1983)."},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1044-0305(01)00336-1"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1074\/mcp.M700274-MCP200"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1074\/mcp.R000001-MCP201"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cell.2021.12.015"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1038\/nature06405"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1038\/nature06404"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1038\/nature26003"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1021\/jasms.8b05315"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1091\/mbc.8.11.2119"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-021-26323-7"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.1002\/mas.21614"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1044-0305(98)00027-0"}],"container-title":["Science Advances"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.science.org\/doi\/pdf\/10.1126\/sciadv.aec7048","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T18:00:39Z","timestamp":1773856839000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.science.org\/doi\/10.1126\/sciadv.aec7048"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,20]]},"references-count":43,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2026,3,20]]}},"alternative-id":["10.1126\/sciadv.aec7048"],"URL":"https:\/\/doi.org\/10.1126\/sciadv.aec7048","relation":{},"ISSN":["2375-2548"],"issn-type":[{"value":"2375-2548","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,20]]},"assertion":[{"value":"2025-09-29","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-13","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-18","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"eaec7048"}}