{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T14:17:24Z","timestamp":1780064244049,"version":"3.54.0"},"reference-count":19,"publisher":"American Society for Microbiology","issue":"1","license":[{"start":{"date-parts":[[2008,1,1]],"date-time":"2008-01-01T00:00:00Z","timestamp":1199145600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.asm.org\/non-commercial-tdm-license"}],"content-domain":{"domain":["journals.asm.org"],"crossmark-restriction":true},"short-container-title":["Clin Vaccine Immunol"],"published-print":{"date-parts":[[2008,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n          <jats:p>The accurate detection and quantitation of cytokines in serum are important in the study of disease mechanisms, pathogenesis, and treatment. Serum cytokines can reflect processes that are occurring at the cellular or tissue level and thus provide a means of indirectly monitoring these processes. Multiplex detection of cytokines allows the simultaneous measurement of multiple cytokines in a sample, increasing the efficiency of measuring the cytokines while reducing the serum sample volumes required for the testing. Two commercially available multiplex platforms were evaluated (Pierce SearchLight and Meso Scale Discovery), using multiplexes capable of simultaneously detecting eight cytokines. The cytokines analyzed in this study were gamma interferon, vascular endothelial growth factor, tumor necrosis factor alpha, interleukin-6 (IL-6), macrophage inflammatory protein 1\u03b2, monocyte chemoattractant protein 1, IL-12p40, and IL-4. The range of quantitation of the platforms, the recovery of spiked cytokines, and the detection of the cytokines in serum samples from subjects with ulcerative colitis, Crohn's disease, rheumatoid arthritis, and psoriasis were examined. The findings showed that the detection of the cytokines was highly dependent upon the platform, with the consistency of the detection of cytokines across platforms being dependent upon the cytokine being analyzed. A careful examination of platform assay performance must be made prior to utilizing multiplex platforms in a study. While some cytokines will give similar patterns of results across platforms, others will be highly variable. The use of the same platform within a study or across studies where data will be compared is advised.<\/jats:p>","DOI":"10.1128\/cvi.00211-07","type":"journal-article","created":{"date-parts":[[2007,11,15]],"date-time":"2007-11-15T02:04:56Z","timestamp":1195092296000},"page":"42-48","update-policy":"https:\/\/doi.org\/10.1128\/asmj-crossmark-policy-page","source":"Crossref","is-referenced-by-count":62,"title":["Simultaneous Detection of Eight Analytes in Human Serum by Two Commercially Available Platforms for Multiplex Cytokine Analysis"],"prefix":"10.1128","volume":"15","author":[{"given":"Gary","family":"Toedter","sequence":"first","affiliation":[{"name":"Department of Clinical Pathology and Experimental Medicine, Centocor R&amp;D, Radnor, Pennsylvania 19087"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karen","family":"Hayden","sequence":"additional","affiliation":[{"name":"Department of Clinical Pathology and Experimental Medicine, Centocor R&amp;D, Radnor, Pennsylvania 19087"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carrie","family":"Wagner","sequence":"additional","affiliation":[{"name":"Department of Clinical Pathology and Experimental Medicine, Centocor R&amp;D, Radnor, Pennsylvania 19087"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carrie","family":"Brodmerkel","sequence":"additional","affiliation":[{"name":"Department of Clinical Pathology and Experimental Medicine, Centocor R&amp;D, Radnor, Pennsylvania 19087"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"235","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1128\/CDLI.6.1.89-95.1999"},{"key":"e_1_3_2_3_2","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.ymeth.2005.11.008","volume":"38","year":"2006","unstructured":"de Jager, W., and G. T. Rijkers. 2006. Solid-phase and bead-based cytokine immunoassay: a comparison. Methods38:294-303.","journal-title":"Methods"},{"key":"e_1_3_2_4_2","first-page":"133","volume":"9","year":"2003","unstructured":"de Jager, W., H. te Velthuis, B. J. Prakken, W. Kuis, and G. T. Rijkers. 2003. Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells. Clin. Diagn. Lab. Immunol.9:133-139.","journal-title":"Clin. Diagn. Lab. Immunol."},{"key":"e_1_3_2_5_2","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.jim.2005.03.009","volume":"300","year":"2005","unstructured":"de Jager, W., B. J. Prakken, J. W. J. Bijlsma, W. Kuis, and G. T. Rijkers. 2005. Improved multiplex immunoassay performance in human plasma and synovial fluid following removal of interfering heterophilic antibodies. J. Immunol. Methods300:124-135.","journal-title":"J. Immunol. Methods"},{"key":"e_1_3_2_6_2","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1378\/chest.118.2.503","volume":"118","year":"2000","unstructured":"Dinarello, C. A. 2000. Proinflammatory cytokines. Chest118:503-508.","journal-title":"Chest"},{"key":"e_1_3_2_7_2","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.ymeth.2005.11.010","volume":"38","year":"2006","unstructured":"Elshal, M. F., and J. P. McCoy. 2006. Multiplex bead array assays: performance evaluation and comparison of sensitivity to ELISA. Methods38:317-323.","journal-title":"Methods"},{"key":"e_1_3_2_8_2","doi-asserted-by":"crossref","first-page":"1581","DOI":"10.1097\/00002030-199813000-00004","volume":"12","year":"1998","unstructured":"Fahey, J. L., J. M. G. Taylor, B. Manna, P. Nishanian, N. Aziz, J. V. Giorgi, and R. Detels. 1998. Prognostic significance of plasma markers of immune activation, HIV viral load and CD4 T-cell measurements. AIDS12:1581-1590.","journal-title":"AIDS"},{"key":"e_1_3_2_9_2","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/S0022-1759(99)00206-9","volume":"235","year":"2000","unstructured":"Hennig, C., L. Rink, U. Fagin, W. J. Jabs, and H. Kirchner. 2000. The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs. J. Immunol. Methods235:71-80.","journal-title":"J. Immunol. Methods"},{"key":"e_1_3_2_10_2","first-page":"35","volume":"618","year":"2004","unstructured":"Khan, S. S., M. S. Smith, D. Reda, A. F. Suffredini, and J. P. McCoy. 2004. Multiplex bead array assays for the detection of soluble cytokines: comparison of sensitivity and quantitative values among kits from multiple manufacturers. Cytometry B Clin. Cytom.618:35-39.","journal-title":"Cytometry B Clin. Cytom."},{"key":"e_1_3_2_11_2","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1038\/nrd2006","volume":"5","year":"2006","unstructured":"Kingsmore, S. F. 2006. Multiplexed protein measurement: technologies and applications of protein and antibody arrays. Nat. Rev. Drug Discov.5:310-321.","journal-title":"Nat. Rev. Drug Discov."},{"key":"e_1_3_2_12_2","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.jim.2005.12.007","volume":"309","year":"2006","unstructured":"Lash, G. E., P. J. Scaife, B. A. Innes, H. A. Otun, S. C. Robson, R. F. Searle, and J. N. Bulmer. 2006. Comparison of three multiplex cytokine analysis systems: Luminex, SearchLight and FASTQuant. J. Immunol. Methods309:205-208.","journal-title":"J. Immunol. Methods"},{"key":"e_1_3_2_13_2","first-page":"325","volume":"11","year":"2004","unstructured":"Martins, T. B., B. M. Pasi, C. M. Litwin, and H. R. Hill. 2004. Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum. Clin. Diagn. Lab. Immunol.11:325-329.","journal-title":"Clin. Diagn. Lab. Immunol."},{"key":"e_1_3_2_14_2","doi-asserted-by":"crossref","first-page":"778","DOI":"10.2144\/99274rr01","volume":"27","year":"1999","unstructured":"Mendoza, L. G., P. McQuary, A. Mongan, R. Gangadharan, S. Brignac, and M. Eggers. 1999. High-throughput microarray-based enzyme-linked immunosorbent assay (ELISA). BioTechniques27:778-788.","journal-title":"BioTechniques"},{"key":"e_1_3_2_15_2","doi-asserted-by":"crossref","first-page":"ii84","DOI":"10.1136\/ard.2003.006916","volume":"63","year":"2004","unstructured":"Moser, B., and K. Willimann. 2004. Chemokines: role in inflammation and immune surveillance. Ann. Rheum. Dis.63(Suppl. II):ii84-ii89.","journal-title":"Ann. Rheum. Dis."},{"key":"e_1_3_2_16_2","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.jim.2004.04.012","volume":"290","year":"2004","unstructured":"Nielsen, U. L., and B. H. Geierstanger. 2004. Multiplexed sandwich assays in microarray format. J. Immunol. Methods290:107-120.","journal-title":"J. Immunol. Methods"},{"key":"e_1_3_2_17_2","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/S0022-1759(01)00543-9","volume":"260","year":"2002","unstructured":"Prabhakar, U., E. Eirikis, and H. M. Davis. 2002. Simultaneous quantification of proinflammatory cytokines in human plasma using the LabMAP assay. J. Immunol. Methods260:207-218.","journal-title":"J. Immunol. Methods"},{"key":"e_1_3_2_18_2","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jim.2004.04.018","volume":"291","year":"2004","unstructured":"Prabhakar, U., E. Eirikis, M. Reddy, E. Silvestro, S. Spitz, C. Pendley, H. M. Davis, and B. E. Miller. 2004. Validation and comparative analysis of a multiplexed assay for the simultaneous quantitative measurement of Th1\/Th2 cytokines in human serum and human peripheral blood mononuclear cell culture supernatants. J. Immunol. Methods291:27-38.","journal-title":"J. Immunol. Methods"},{"key":"e_1_3_2_19_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jim.2006.03.019","volume":"316","year":"2006","unstructured":"Urbanowska, T., S. Mangialaio, C. Zickler, S. Cheevapruk, P. Hasler, S. Regenass, and F. Legay. 2006. Protein microarray platform for the multiplex analysis of biomarkers in human serum. J. Immunol. Methods316:1-7.","journal-title":"J. Immunol. Methods"},{"key":"e_1_3_2_20_2","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1038\/sj.bjc.6600075","volume":"86","year":"2002","unstructured":"Werther, K., I. J. Christensen, H. J. Nielsen, and the Danish RANX05 Colorectal Cancer Study Group. 2002. Prognostic impact of matched preoperative plasma and serum VEGF in patients with primary colorectal carcinoma. Br. J. Cancer86:417-423.","journal-title":"Br. J. Cancer"}],"container-title":["Clinical and Vaccine Immunology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.asm.org\/doi\/pdf\/10.1128\/CVI.00211-07","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.asm.org\/doi\/pdf\/10.1128\/CVI.00211-07","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T15:54:31Z","timestamp":1627574071000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.asm.org\/doi\/10.1128\/CVI.00211-07"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,1]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,1]]}},"alternative-id":["10.1128\/CVI.00211-07"],"URL":"https:\/\/doi.org\/10.1128\/cvi.00211-07","relation":{},"ISSN":["1556-6811","1556-679X"],"issn-type":[{"value":"1556-6811","type":"print"},{"value":"1556-679X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,1]]},"assertion":[{"value":"2007-05-24","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2007-11-06","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-12-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}