{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:34:54Z","timestamp":1769092494529,"version":"3.49.0"},"reference-count":8,"publisher":"American Society for Microbiology","issue":"2","license":[{"start":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T00:00:00Z","timestamp":1611187200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.asm.org\/non-commercial-tdm-license"}],"content-domain":{"domain":["journals.asm.org"],"crossmark-restriction":true},"short-container-title":["J Clin Microbiol"],"published-print":{"date-parts":[[2021,1,21]]},"abstract":"<jats:p>The Quidel Sofia severe acute respiratory syndrome (SARS) fluorescent immunoassay (FIA) test (SOFIA) is a rapid antigen immunoassay for the detection of SARS coronavirus 2 (SARS-CoV-2) proteins from nasal or nasopharyngeal swab specimens. The purpose of this study was to compare the results of the SOFIA test to those of the Hologic Aptima SARS-CoV-2 TMA test (APTIMA TMA), a high-throughput molecular diagnostic test that uses transcription-mediated amplification (TMA) for the detection of SARS-CoV-2 nucleic acid from upper respiratory tract specimens.<\/jats:p>","DOI":"10.1128\/jcm.02727-20","type":"journal-article","created":{"date-parts":[[2020,11,26]],"date-time":"2020-11-26T11:57:38Z","timestamp":1606391858000},"update-policy":"https:\/\/doi.org\/10.1128\/asmj-crossmark-policy-page","source":"Crossref","is-referenced-by-count":43,"title":["Comparison of the Quidel Sofia SARS FIA Test to the Hologic Aptima SARS-CoV-2 TMA Test for Diagnosis of COVID-19 in Symptomatic Outpatients"],"prefix":"10.1128","volume":"59","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3383-8665","authenticated-orcid":false,"given":"Eric T.","family":"Beck","sequence":"first","affiliation":[{"name":"Department of Microbiology, ACL Laboratories, West Allis, Wisconsin, USA"},{"name":"Advocate Aurora Health, Milwaukee, Wisconsin, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wendy","family":"Paar","sequence":"additional","affiliation":[{"name":"Department of Microbiology, ACL Laboratories, West Allis, Wisconsin, USA"},{"name":"Advocate Aurora Health, Milwaukee, Wisconsin, USA"},{"name":"Aurora West Bend Clinic, West Bend, Wisconsin, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lara","family":"Fojut","sequence":"additional","affiliation":[{"name":"Advocate Aurora Health, Milwaukee, Wisconsin, USA"},{"name":"Department of Urgent Care, Primary Care Service Line, Aurora Health Care Medical Group, Milwaukee, Wisconsin, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jordan","family":"Serwe","sequence":"additional","affiliation":[{"name":"Advocate Aurora Health, Milwaukee, Wisconsin, USA"},{"name":"Aurora West Bend Clinic, West Bend, Wisconsin, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Renee R.","family":"Jahnke","sequence":"additional","affiliation":[{"name":"Advocate Aurora Health, Milwaukee, Wisconsin, USA"},{"name":"Department of Urgent Care, Primary Care Service Line, Aurora Health Care Medical Group, Milwaukee, Wisconsin, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"235","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1128\/JCM.01816-15"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1093\/cid\/cix461"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.7326\/M17-0848"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcv.2020.104455"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/cid\/ciaa638"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/cid\/ciaa1491"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10096-020-03913-9"},{"key":"e_1_3_2_9_2","doi-asserted-by":"crossref","unstructured":"Larremore DB Wilder B Lester E Shehata S Burke JM Hay JA Tambe M Mina MJ Parker R. 2020. Test sensitivity is secondary to frequency and turnaround time for COVID-19 surveillance. medRxiv https:\/\/www.medrxiv.org\/content\/10.1101\/2020.06.22.20136309v3.","DOI":"10.1101\/2020.06.22.20136309"}],"container-title":["Journal of Clinical Microbiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.asm.org\/doi\/pdf\/10.1128\/JCM.02727-20","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.asm.org\/doi\/pdf\/10.1128\/JCM.02727-20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,5]],"date-time":"2022-03-05T10:54:32Z","timestamp":1646477672000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.asm.org\/doi\/10.1128\/JCM.02727-20"}},"subtitle":[],"editor":[{"given":"Melissa B.","family":"Miller","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2021,1,21]]},"references-count":8,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,1,21]]}},"alternative-id":["10.1128\/JCM.02727-20"],"URL":"https:\/\/doi.org\/10.1128\/jcm.02727-20","relation":{},"ISSN":["0095-1137","1098-660X"],"issn-type":[{"value":"0095-1137","type":"print"},{"value":"1098-660X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,21]]},"assertion":[{"value":"2020-10-29","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-11-21","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-01-21","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e02727-20"}}