{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T13:41:45Z","timestamp":1790862105835,"version":"4.1.0"},"reference-count":20,"publisher":"American Society for Microbiology","issue":"6","license":[{"start":{"date-parts":[[1999,6,1]],"date-time":"1999-06-01T00:00:00Z","timestamp":928195200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.asm.org\/non-commercial-tdm-license"}],"content-domain":{"domain":["journals.asm.org"],"crossmark-restriction":true},"short-container-title":["J Clin Microbiol"],"published-print":{"date-parts":[[1999,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n          <jats:p>\n            A total of 9,446 blood cultures were collected from adult patients at three university-affiliated hospitals. Of these, 8,943 cultures were received with both aerobic bottles filled adequately; 885 yielded 1,016 microorganisms, including 622 isolates (61%) that were the cause of sepsis, 337 isolates (33%) that were contaminants, and 57 isolates (6%) that were indeterminate as the cause of sepsis. With the exception of\n            <jats:italic>Staphylococcus aureus<\/jats:italic>\n            , which was recovered more often from VITAL aerobic bottles, more pathogenic microorganisms were recovered from BACTEC NR6 (aerobic) bottles than from VITAL aerobic bottles. Growth of pathogenic microorganisms was detected earlier in VITAL aerobic bottles. A total of 8,647 blood cultures were received with both anaerobic bottles filled adequately; 655 yielded 740 microorganisms, including 486 isolates (66%) that were the cause of sepsis, 215 isolates (29%) that were contaminants, and 39 isolates (6%) that were indeterminate as the cause of sepsis. More pathogenic microorganisms were recovered from VITAL anaerobic bottles than from BACTEC NR7 (anaerobic) bottles. Growth of pathogenic microorganisms was detected earlier in VITAL anaerobic bottles. In 8,500 sets all four bottles were received adequately filled. When paired aerobic and anaerobic bottle sets (systems) were compared, more pathogenic microorganisms (again with the exception of\n            <jats:italic>S. aureus<\/jats:italic>\n            ) were recovered from the BACTEC system. For the 304 septic episodes (253 unimicrobial and 51 polymicrobial), significantly more were detected by the BACTEC system. We conclude that VITAL requires modification to improve recovery of pathogenic microorganisms to make it competitive with other commercially available blood culture systems.\n          <\/jats:p>","DOI":"10.1128\/jcm.37.6.1709-1713.1999","type":"journal-article","created":{"date-parts":[[2019,12,31]],"date-time":"2019-12-31T17:45:38Z","timestamp":1577814338000},"page":"1709-1713","update-policy":"https:\/\/doi.org\/10.1128\/asmj-crossmark-policy-page","source":"Crossref","is-referenced-by-count":8,"title":["Controlled Clinical Comparison of bioMe\u0301rieux VITAL and BACTEC NR-660 Blood Culture Systems for Detection of Bacteremia and Fungemia in Adults"],"prefix":"10.1128","volume":"37","author":[{"given":"Michael L.","family":"Wilson","sequence":"first","affiliation":[{"name":"<!--label omitted: 1-->Department of Pathology and Laboratory Services, Denver Health, Denver, Colorado 802041;"},{"name":"<!--label omitted: 2-->Department of Pathology, University of Colorado School of Medicine, Denver, Colorado 802622;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stanley","family":"Mirrett","sequence":"additional","affiliation":[{"name":"<!--label omitted: 3-->Clinical Microbiology Laboratory, Duke University Medical Center,3 and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. Clifford","family":"McDonald","sequence":"additional","affiliation":[{"name":"<!--label omitted: 3-->Clinical Microbiology Laboratory, Duke University Medical Center,3 and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melvin P.","family":"Weinstein","sequence":"additional","affiliation":[{"name":"<!--label omitted: 4-->Microbiology Laboratory, Robert Wood Johnson University Hospital4 and"},{"name":"<!--label omitted: 5-->Departments of Medicine5 and"},{"name":"<!--label omitted: 6-->Pathology,6 University of Medicine and Dentistry of New Jersey-Robert Wood Johnson Medical School, New Brunswick, New Jersey 08901"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose","family":"Fune","sequence":"additional","affiliation":[{"name":"<!--label omitted: 5-->Departments of Medicine5 and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. Barth","family":"Reller","sequence":"additional","affiliation":[{"name":"<!--label omitted: 3-->Clinical Microbiology Laboratory, Duke University Medical Center,3 and"},{"name":"<!--label omitted: 7-->Departments of Pathology7 and"},{"name":"<!--label omitted: 8-->Medicine,8Duke University School of Medicine, Durham, North Carolina 27710; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"235","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.16.5.968-970.1982"},{"key":"e_1_3_2_3_2","unstructured":"Dunne\nW. M.\nNolte\nF. S.\nWilson\nM. L.\nCumitech 1B. Blood cultures III. Coordinating ed. J. Hindler\n1997\nAmerican Society for Microbiology\nWashington D.C"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(74)90813-7"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.2.4.296-299.1975"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.23.2.262-266.1986"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(73)90792-7"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0732-8893(91)90044-G"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01708557"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.33.8.2098-2101.1995"},{"key":"e_1_3_2_11_2","unstructured":"McNemar\nQ.\nPsychological statistics\n3rd ed.\n1962\n209\n239\nJohn Wiley & Sons Inc.\nNew York N.Y"},{"key":"e_1_3_2_12_2","unstructured":"Murray\nP. R.\nBaron\nE. J.\nPfaller\nM. A.\nTenover\nF. C.\nYolken\nR. H.\nManual of clinical microbiology\n6th ed.\n1995\nAmerican Society for Microbiology\nWashington D.C"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1128\/CMR.10.3.444"},{"key":"e_1_3_2_14_2","unstructured":"Reller\nL. B.\nMcDonald\nL. C.\nWeinstein\nM. P.\nFune\nJ.\nWilson\nM. L.\nControlled comparison of bioMerieux VITAL and BACTEC NR660 blood culture systems abstr. C-16\nAbstracts of the 95th General Meeting of the American Society for Microbiology 1995.\n1995\n3\nAmerican Society for Microbiology\nWashington D.C"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.34.5.1327-1329.1996"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.21.5.815-818.1985"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1093\/clinids\/5.1.35"},{"key":"e_1_3_2_18_2","unstructured":"Wilson\nM. L.\nContinuous-monitoring blood culture systems\u2014update. Check sample MB96-10 (MB-261).\n1996\nAmerican Society of Clinical Pathologists\nChicago Ill"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.30.1.63-66.1992"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.30.2.323-329.1992"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1128\/jcm.35.8.2007-2012.1997"}],"container-title":["Journal of Clinical Microbiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.asm.org\/doi\/pdf\/10.1128\/JCM.37.6.1709-1713.1999","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.asm.org\/doi\/pdf\/10.1128\/JCM.37.6.1709-1713.1999","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,5]],"date-time":"2022-03-05T00:02:57Z","timestamp":1646438577000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.asm.org\/doi\/10.1128\/JCM.37.6.1709-1713.1999"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,6]]},"references-count":20,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1999,6]]}},"alternative-id":["10.1128\/JCM.37.6.1709-1713.1999"],"URL":"https:\/\/doi.org\/10.1128\/jcm.37.6.1709-1713.1999","relation":{},"ISSN":["0095-1137","1098-660X"],"issn-type":[{"value":"0095-1137","type":"print"},{"value":"1098-660X","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,6]]},"assertion":[{"value":"1998-11-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"1999-02-23","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"1999-06-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}