{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T15:51:06Z","timestamp":1786117866994,"version":"build-2736575974"},"reference-count":41,"publisher":"American Society for Microbiology","issue":"8","license":[{"start":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T00:00:00Z","timestamp":1785801600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T00:00:00Z","timestamp":1785801600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.asm.org\/non-commercial-tdm-license"}],"content-domain":{"domain":["journals.asm.org"],"crossmark-restriction":true},"short-container-title":["Microbiol Spectr"],"published-print":{"date-parts":[[2026,8,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      The IDEXX Legiolert test has been implemented for the quantification of\n                      <jats:italic toggle=\"yes\">Legionella pneumophila<\/jats:italic>\n                      in a variety of potable and non-potable water matrices. For example, through coordination with the state regulatory agency, the Southern Nevada Water Authority (SNWA) has implemented treatment strategies and corresponding\n                      <jats:italic toggle=\"yes\">L. pneumophila<\/jats:italic>\n                      monitoring (via Legiolert) to ensure groundwater quality and public health protection. Because of its specificity to\n                      <jats:italic toggle=\"yes\">L. pneumophila<\/jats:italic>\n                      , confirmation of a positive Legiolert test is often assumed to be unnecessary, although high false positive rates have previously been reported for Legiolert testing of groundwater systems. This study evaluated four confirmation methodologies on liquid media harvested from Legiolert-positive trays: latex agglutination, MALDI-MS, rapid qPCR for the\n                      <jats:italic toggle=\"yes\">mip<\/jats:italic>\n                      and\n                      <jats:italic toggle=\"yes\">srkA<\/jats:italic>\n                      genes, and BCYE plating (\u00b1L-cysteine). With the exception of BCYE, these confirmation methods provide results in &lt;24 h, allowing for rapid regulatory and\/or public health response. Of 108 presumptive positive analyses of groundwater samples collected in Southern Nevada, only two were ultimately determined to be false positive Legiolert results, although one prompted the shutdown of the corresponding groundwater well. qPCR of the\n                      <jats:italic toggle=\"yes\">mip<\/jats:italic>\n                      gene had the highest\n                      <jats:italic toggle=\"yes\">L. pneumophila<\/jats:italic>\n                      confirmation rate (96%), followed by MALDI-MS (92%), latex agglutination (88%), and BCYE (\u00b1L-cysteine) (88%). Although Legiolert alone proved to be effective and relatively accurate in detecting\n                      <jats:italic toggle=\"yes\">L. pneumophila<\/jats:italic>\n                      , confirmation testing yielded valuable supporting information, including serogroup determination and false positive identification (\n                      <jats:italic toggle=\"yes\">Stenotrophomonas maltophilia<\/jats:italic>\n                      ). Collectively, these data highlight the benefits and drawbacks of various\n                      <jats:italic toggle=\"yes\">L. pneumophila<\/jats:italic>\n                      confirmation methodologies for reporting and decision-making by SNWA and other drinking water utilities.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>IMPORTANCE<\/jats:title>\n                    <jats:p>\n                      In the United States,\n                      <jats:italic toggle=\"yes\">Legionella pneumophila<\/jats:italic>\n                      is the leading cause of drinking water-associated illnesses, hospitalization, and deaths. It is the causative agent of Legionnaires\u2019 disease and the less severe Pontiac Fever. As awareness of\n                      <jats:italic toggle=\"yes\">L. pneumophila<\/jats:italic>\n                      risks increases and monitoring plans are implemented, it is imperative that laboratory analysts, practitioners, and decision-makers understand the limitations of available methods and the value of confirmation in increasing data confidence and informing appropriate actions. Groundwater is commonly used as a drinking water source for public and private systems and generally has less stringent treatment requirements than other sources. Studies have described groundwater as an environmental reservoir for\n                      <jats:italic toggle=\"yes\">L. pneumophila<\/jats:italic>\n                      , but there have also been reports of high false positive rates when monitoring groundwater, particularly when using IDEXX Legiolert. Therefore, the results from this study provide critical knowledge to those monitoring\n                      <jats:italic toggle=\"yes\">L. pneumophila<\/jats:italic>\n                      and using the data for regulatory compliance and\/or operational decision-making.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1128\/spectrum.01228-26","type":"journal-article","created":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T01:19:26Z","timestamp":1782868766000},"update-policy":"https:\/\/doi.org\/10.1128\/asmj-crossmark-policy-page","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of\n                    <i>Legionella pneumophila<\/i>\n                    confirmation methods following IDEXX Legiolert analysis of groundwater"],"prefix":"10.1128","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8145-428X","authenticated-orcid":true,"given":"Christina M.","family":"Morrison","sequence":"first","affiliation":[{"id":[{"id":"https:\/\/ror.org\/01h772984","id-type":"ROR","asserted-by":"publisher"}],"name":"Southern Nevada Water Authority","place":["Las Vegas, USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillip","family":"Wang","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/01h772984","id-type":"ROR","asserted-by":"publisher"}],"name":"Southern Nevada Water Authority","place":["Las Vegas, USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriela","family":"Portillo-Chamul","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/01h772984","id-type":"ROR","asserted-by":"publisher"}],"name":"Southern Nevada Water Authority","place":["Las Vegas, USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Monahan","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/01h772984","id-type":"ROR","asserted-by":"publisher"}],"name":"Southern Nevada Water Authority","place":["Las Vegas, USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Chung","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/01h772984","id-type":"ROR","asserted-by":"publisher"}],"name":"Southern Nevada Water Authority","place":["Las Vegas, USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Gerrity","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/01h772984","id-type":"ROR","asserted-by":"publisher"}],"name":"Southern Nevada Water Authority","place":["Las Vegas, USA"]},{"id":[{"id":"https:\/\/ror.org\/01keh0577","id-type":"ROR","asserted-by":"publisher"}],"name":"Department of Civil and Environmental Engineering and Construction, University of Nevada","place":["Las Vegas, USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"235","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(15)60078-2"},{"key":"e_1_3_3_3_2","unstructured":"Centers for Disease Control and Prevention. 2025. BEAM (Bacteria Enterics Ameba and Mycotics) dashboard. U.S. Department of Health and Human Services. Available from: www.cdc.gov\/ncezid\/dfwed\/BEAM-dashboard.html"},{"key":"e_1_3_3_4_2","unstructured":"European Centre for Disease Prevention and Control. 2026. Legionnaires\u2019 diease: annual epidemiological report for 2023."},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1021\/acs.est.5b00142"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.33.12.1179"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.3389\/fcimb.2017.00477"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1021\/acs.est.5c04958"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1021\/acs.est.5c05335"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198002143020703"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-0691.2006.01447.x"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/PHH.0000000000000558"},{"key":"e_1_3_3_13_2","volume-title":"Management of Legionella in water systems","author":"National Academies of Science, Engineering and Medicine","year":"2020","unstructured":"National Academies of Science, Engineering and Medicine. 2020. Management of Legionella in water systems. The National Academies Press."},{"key":"e_1_3_3_14_2","unstructured":"US EPA. 1998. Interim enhanced surface water treatment rule. Federal Register."},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.watres.2022.118615"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1128\/AEM.02956-18"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1128\/AEM.01942-19"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2024.173317"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1093\/femsre\/fuaf022"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/lam.13273"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1039\/C9EW00109C"},{"key":"e_1_3_3_22_2","unstructured":"Centers for Disease Control and Prevention. 2026. Toolkit for controlling Legionella in common sources of exposure (Legionella control toolkit): information on controlling Legionella in commonly implicated sources of Legionaires\u2019 disease outbreaks. Internet. Available from: https:\/\/www.cdc.gov\/legionella\/wmp\/control-toolkit\/index.html"},{"key":"e_1_3_3_23_2","unstructured":"Lang RC. 2023. Official correspondence with NDEP-BSDW (No. 0090-E-20220316-CL-006749-21). Reno NV."},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1021\/acs.est.5c09407"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1002\/aws2.1122"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.watres.2023.119989"},{"key":"e_1_3_3_27_2","unstructured":"International Organization for Standardization. 2017. ISO 11731:2017(E) water quality- enumeration of Legionella."},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.diagmicrobio.2010.11.014"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.diagmicrobio.2008.05.004"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1128\/AEM.02261-10"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1128\/JCM.00157-21"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1086\/341087"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0154389"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.1086\/345438"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.1002\/biot.202300135"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.3390\/w10081012"},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1128\/msystems.01406-21"},{"key":"e_1_3_3_38_2","doi-asserted-by":"publisher","DOI":"10.1128\/CMR.00019-11"},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.4265\/bio.27.81"},{"key":"e_1_3_3_40_2","doi-asserted-by":"publisher","DOI":"10.1128\/spectrum.02118-22"},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.3390\/pathogens9090690"},{"key":"e_1_3_3_42_2","doi-asserted-by":"publisher","DOI":"10.1128\/aem.00236-25"}],"container-title":["Microbiology Spectrum"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.asm.org\/doi\/pdf\/10.1128\/spectrum.01228-26","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.asm.org\/doi\/pdf\/10.1128\/spectrum.01228-26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T14:39:28Z","timestamp":1786027168000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.asm.org\/doi\/10.1128\/spectrum.01228-26"}},"subtitle":[],"editor":[{"given":"Ping","family":"Ren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2026,8,4]]},"references-count":41,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8,4]]}},"alternative-id":["10.1128\/spectrum.01228-26"],"URL":"https:\/\/doi.org\/10.1128\/spectrum.01228-26","relation":{},"ISSN":["2165-0497"],"issn-type":[{"value":"2165-0497","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,4]]},"assertion":[{"value":"2026-04-08","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-07","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-30","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e01228-26"}}