{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T16:15:59Z","timestamp":1783008959837,"version":"3.54.5"},"reference-count":40,"publisher":"Kaifukuki Rehabilitation Ward Association","issue":"0","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JJCRS","Jpn J Compr Rehabil Sci"],"published-print":{"date-parts":[[2025,5,30]]},"DOI":"10.11336\/jjcrs.16.19","type":"journal-article","created":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T18:07:59Z","timestamp":1749146879000},"page":"19-29","source":"Crossref","is-referenced-by-count":3,"title":["Real-Time Estimation of Lower Limb Posture and Joint Angles Using Wearable IMUs:"],"prefix":"10.11336","volume":"16","author":[{"given":"Shun","family":"Kanega","sequence":"first","affiliation":[{"name":"Faculty of Human Sciences, Waseda University"},{"name":"National Hospital Organization Murayama Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshihiro","family":"Muraoka","sequence":"additional","affiliation":[{"name":"Faculty of Human Sciences, Waseda University"},{"name":"National Hospital Organization Murayama Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"34939","reference":[{"key":"1","doi-asserted-by":"publisher","unstructured":"1.                       Ota M, Aoki J, Fuji C, Yamada T, Tamori M. Effects of Gait Training Using Functional Electrical Stimulation of the Tibialis Anterior Muscle on the Gait Pattern of Convalescent Hemiplegic Stroke Patients. Rigakuryoho Kagaku 2021; 36(1): 119-23. Japanese.","DOI":"10.1589\/rika.36.119"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2.                       Jaqueline da Cunha M, Rech KD, Salazar AP, Pagnussat AS. Functional electrical stimulation of the peroneal nerve improves post-stroke gait speed when combined with physiotherapy. A systematic review and meta-analysis. Ann Phys Rehabil Med 2021; 64(1): 101388.","DOI":"10.1016\/j.rehab.2020.03.012"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3.                       Marquez-Chin C, Popovic MR. Functional electrical stimulation therapy for restoration of motor function after spinal cord injury and stroke: a review. Biomed Eng Online 2020; 19(1): 34.","DOI":"10.1186\/s12938-020-00773-4"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4.                       Hausdorff JM, Ring H. Effects of a new radio frequency-controlled neuroprosthesis on gait symmetry and rhythmicity in patients with chronic hemiparesis. Am J Phys Med Rehabil 2008; 87(1): 4-13.","DOI":"10.1097\/PHM.0b013e31815e6680"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5.                       Bethoux F, Rogers HL, Nolan KJ, Abrams GM, Annaswamy TM, Brandstater M, et al. The effects of peroneal nerve functional electrical stimulation versus ankle-foot orthosis in patients with chronic stroke: a randomized controlled trial. Neurorehabil Neural Repair 2014; 28(7): 688-97.","DOI":"10.1177\/1545968314521007"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6.                       Prasanth H, Caban M, Keller U, Courtine G, Ijspeert A, Vallery H, von Zitzewitz J. Wearable Sensor-Based Real-Time Gait Detection: A Systematic Review. Sensors. 2021; 21(8): 2727.","DOI":"10.3390\/s21082727"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7.                       Rueterbories J, Spaich EG, Larsen B, Andersen OK. Methods for gait event detection and analysis in ambulatory systems. Med Eng Phys. 2010; 32(6): 545-52.","DOI":"10.1016\/j.medengphy.2010.03.007"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8.                       Kotiadis D, Hermens HJ, Veltink PH. Inertial Gait Phase Detection for control of a drop foot stimulator Inertial sensing for gait phase detection. Med Eng Phys. 2010; 32(4): 287-97.","DOI":"10.1016\/j.medengphy.2009.10.014"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9.                       Mansfield A, Lyons GM. The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking. Med Eng Phys. 2003; 25(10): 879-85.","DOI":"10.1016\/S1350-4533(03)00116-4"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10.                       Picerno P. 25 years of lower limb joint kinematics by using inertial and magnetic sensors: A review of methodological approaches. Gait Posture 2017; 51: 239-46.","DOI":"10.1016\/j.gaitpost.2016.11.008"},{"key":"11","doi-asserted-by":"publisher","unstructured":"11.                       Tadano S, Takeda R, Miyagawa H. Three dimensional gait analysis using wearable acceleration and gyro sensors based on quaternion calculations. Sensors 2013; 13(7): 9321-43.","DOI":"10.3390\/s130709321"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12.                       Cooper G, Sheret I, McMillan L, Siliverdis K, Sha N, Hodgins D, Kenney L, Howard D. Inertial sensor-based knee flexion\/extension angle estimation. J Biomech 2009; 42(16): 2678-85.","DOI":"10.1016\/j.jbiomech.2009.08.004"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13.                       Saito A, Miyawaki K, Kizawa S, Kobayashi Y. A study on estimating the knee joint angle during walking using the motion sensors (Focusing on the effect of centrifugal acceleration and tangential acceleration), Transactions of the JSME 2018; 84(857): 17-00488.","DOI":"10.1299\/transjsme.17-00488"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14.                       Sy LWF, Lovell NH, Redmond SJ. Estimating Lower Limb Kinematics Using a Lie Group Constrained Extended Kalman Filter with a Reduced Wearable IMU Count and Distance Measurements. Sensors 2020; 20(23): 6829.","DOI":"10.3390\/s20236829"},{"key":"15","doi-asserted-by":"publisher","unstructured":"15.                       Feldhege F, Mau-Moeller A, Lindner T, Hein A, Markschies A, Zettl UK, Bader R. Accuracy of a custom physical activity and knee angle measurement sensor system for patients with neuromuscular disorders and gait abnormalities. Sensors 2015; 15(5): 10734-52.","DOI":"10.3390\/s150510734"},{"key":"16","doi-asserted-by":"publisher","unstructured":"16.                       Mahony RE, Hamel T, Pflimlin JM. Nonlinear Complementary Filters on the Special Orthogonal Group. IEEE Transactions on Automatic Control 2008; 53(5): 1203-18.","DOI":"10.1109\/TAC.2008.923738"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17.                       Madgwick SO, Harrison AJ, Vaidyanathan R. Estimation of IMU and MARG orientation using a gradient descent algorithm. IEEE International Conference on Rehabilitation Robotics 2011, 1-7.","DOI":"10.1109\/ICORR.2011.5975346"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18.                       Feng K, Li J, Zhang X, Shen C, Bi Y, Zheng T, Liu J. A New Quaternion-Based Kalman Filter for Real-Time Attitude Estimation Using the Two-Step Geometrically-Intuitive Correction Algorithm. Sensors 2017; 17(9): 2146.","DOI":"10.3390\/s17092146"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19.                       de Almeida TF, Morya E, Rodrigues AC, de Azevedo Dantas AFO. Development of a Low-Cost Open-Source Measurement System for Joint Angle Estimation. Sensors 2021; 21(19): 6477.","DOI":"10.3390\/s21196477"},{"key":"20","doi-asserted-by":"publisher","unstructured":"20.                       Fernandez IG, Ahmad SA, Wada C. Inertial Sensor-Based Instrumented Cane for Real-Time Walking Cane Kinematics Estimation. Sensors 2020; 20(17): 4675.","DOI":"10.3390\/s20174675"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21.                       Souss\u00e9 R, Verd\u00fa J, Jauregui R, Ferrer-Roca V, Balocco S. Non-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors. J Biomech 2020; 98: 109429.","DOI":"10.1016\/j.jbiomech.2019.109429"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22.                       Bachmann ER, Xiaoping Yun, Peterson CW. An investigation of the effects of magnetic variations on inertial\/magnetic orientation sensors. IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA &apos;04. 2004; 2(2): 1115-22.","DOI":"10.1109\/ROBOT.2004.1307974"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23.                       de Vries WH, Veeger HE, Baten CT, van der Helm FC. Magnetic distortion in motion labs, implications for validating inertial magnetic sensors. Gait Posture 2009; 29(4): 535-41.","DOI":"10.1016\/j.gaitpost.2008.12.004"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24.                       d&apos;Andrea F, Taylor P, Yang K, Heller B. Can inertial measurement unit sensors evaluate foot kinematics in drop foot patients using functional electrical stimulation? Front Hum Neurosci 2023; 17: 1225086.","DOI":"10.3389\/fnhum.2023.1225086"},{"key":"25","doi-asserted-by":"publisher","unstructured":"25.                       Niswander W, Wang W, Kontson K. Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics. Sensors 2020; 20(21): 5993.","DOI":"10.3390\/s20215993"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26.                       Fasel B, Sp\u00f6rri J, Sch\u00fctz P, Lorenzetti S, Aminian K. Validation of functional calibration and strap-down joint drift correction for computing 3D joint angles of knee, hip, and trunk in alpine skiing. PLoS One 2017; 12(7): e0181446.","DOI":"10.1371\/journal.pone.0181446"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27.                       Favre J, Jolles BM, Aissaoui R, Aminian K. Ambulatory measurement of 3D knee joint angle. J Biomech 2008; 41(5): 1029-35.","DOI":"10.1016\/j.jbiomech.2007.12.003"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28.                       Motoya R, Yamamoto S, Naoe M, Taniguchi R, Kawahara A, Iwata T. Classification of abnormal gait patterns of poststroke hemiplegic patients in principal component analysis. Jpn J Compr Rehabil Sci. 2022; 12: 70-7.","DOI":"10.11336\/jjcrs.12.70"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29.                       Bae YH, Ko YJ, Chang WH, Lee JH, Lee KB, Park YJ, Ha HG, Kim YH. Effects of Robot-assisted Gait Training Combined with Functional Electrical Stimulation on Recovery of Locomotor Mobility in Chronic Stroke Patients: A Randomized Controlled Trial. J Phys Ther Sci. 2014; 26(12): 1949-53.","DOI":"10.1589\/jpts.26.1949"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30.                       Bethoux F, Rogers HL, Nolan KJ, Abrams GM, Annaswamy T, Brandstater M, Browne B, Burnfield JM, Feng W, Freed MJ, Geis C, Greenberg J, Gudesblatt M, Ikramuddin F, Jayaraman A, Kautz SA, Lutsep HL, Madhavan S, Meilahn J, Pease WS, Rao N, Seetharama S, Sethi P, Turk MA, Wallis RA, Kufta C. Long-Term Follow-up to a Randomized Controlled Trial Comparing Peroneal Nerve Functional Electrical Stimulation to an Ankle Foot Orthosis for Patients With Chronic Stroke. Neurorehabil Neural Repair. 2015; 29(10): 911-22.","DOI":"10.1177\/1545968315570325"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31.                       Morone G, Fusco A, Di Capua P, Coiro P, Pratesi L. Walking training with foot drop stimulator controlled by a tilt sensor to improve walking outcomes: a randomized controlled pilot study in patients with stroke in subacute phase. Stroke Res Treat. 2012; 2012: 523564.","DOI":"10.1155\/2012\/523564"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32.                       Fico VM, Arribas CP, Soaje AR, Prats M\u00c1, Utrera SR, V\u00e1zquez AL, et al. Implementing the Unscented Kalman Filter on an embedded system: A lesson learnt. IEEE International Conference on Industrial Technology (ICIT) 2015; 2010-2014.","DOI":"10.1109\/ICIT.2015.7125391"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33.                       Valade A, Acco P, Grabolosa P, Fourniols JY. A Study about Kalman Filters Applied to Embedded Sensors. Sensors 2017; 17(12): 2810.","DOI":"10.3390\/s17122810"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34.                       Caruso M, Sabatini AM, Laidig D, Seel T, Knaflitz M, Della Croce U, Cereatti A. Analysis of the Accuracy of Ten Algorithms for Orientation Estimation Using Inertial and Magnetic Sensing under Optimal Conditions: One Size Does Not Fit All. Sensors 2021; 21(7): 2543.","DOI":"10.3390\/s21072543"},{"key":"35","doi-asserted-by":"crossref","unstructured":"35.                       Lora-Millan JS, Hidalgo AF, Rocon E. An IMUs-Based Extended Kalman Filter to Estimate Gait Lower Limb Sagittal Kinematics for the Control of Wearable Robotic Devices. IEEE Access 2021; 9: 144540-144554.","DOI":"10.1109\/ACCESS.2021.3122160"},{"key":"36","doi-asserted-by":"crossref","unstructured":"36.                       Teruyama Y, Watanabe T. Effectiveness of variable-gain Kalman filter based on angle error calculated from acceleration signals in lower limb angle measurement with inertial sensors. Comput Math Methods Med 2013; 2013: 398042.","DOI":"10.1155\/2013\/398042"},{"key":"37","doi-asserted-by":"crossref","unstructured":"37.                       Palermo E, Rossi S, Patan\u00e9 F, Petrarca M, Castelli E, Cappa P. Experimental validation of a sensor to segment calibration procedure for MIMU based gait analysis. Gait &amp; Posture 2013; 38: S110.","DOI":"10.1016\/j.gaitpost.2013.07.223"},{"key":"38","doi-asserted-by":"crossref","unstructured":"38.                       Han YC, Wong KI, Murray I. 2-Point Error Estimation Algorithm for 3-D Thigh and Shank Angles Estimation Using IMU. IEEE Sensors Journal 2018; 18: 8525-31.","DOI":"10.1109\/JSEN.2018.2865764"},{"key":"39","doi-asserted-by":"crossref","unstructured":"39.                       Akbarshahi M, Schache AG, Fernandez JW, Baker R, Banks S, Pandy MG. Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity. J Biomech 2010; 43(7): 1292-301.","DOI":"10.1016\/j.jbiomech.2010.01.002"},{"key":"40","doi-asserted-by":"crossref","unstructured":"40.                       McGrath T, Stirling L. Body-Worn IMU-Based Human Hip and Knee Kinematics Estimation during Treadmill Walking. Sensors 2022; 22(7): 2544.","DOI":"10.3390\/s22072544"}],"container-title":["Japanese Journal of Comprehensive Rehabilitation Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjcrs\/16\/0\/16_19\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T04:23:29Z","timestamp":1757132609000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjcrs\/16\/0\/16_19\/_article"}},"subtitle":["Reproduced Hemiparetic and Normal Gait"],"short-title":[],"issued":{"date-parts":[[2025,5,30]]},"references-count":40,"journal-issue":{"issue":"0","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.11336\/jjcrs.16.19","relation":{},"ISSN":["2185-5323"],"issn-type":[{"value":"2185-5323","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,30]]}}}