{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T16:35:22Z","timestamp":1757608522019,"version":"3.44.0"},"reference-count":21,"publisher":"BMJ","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arch Dis Child Fetal Neonatal Ed"],"published-print":{"date-parts":[[2008,3]]},"abstract":"<jats:sec>\n                  <jats:title>Objectives:<\/jats:title>\n                  <jats:p>To compare the accuracy of a new transcutaneous bilirubinometer, BiliMed (Medick SA, Paris, France) with BiliCheck (Respironics, Marietta, GA, USA), a widely available instrument, and with total serum bilirubin measurement.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Design:<\/jats:title>\n                  <jats:p>A prospective double-blind study comparing the two devices was carried out. 686 healthy newborns needing measurement of their bilirubin were enrolled over a 4-month period. Serum and transcutaneous bilirubin measurements were taken with both devices within 15 minutes. The order of use of the instruments was randomised.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Setting:<\/jats:title>\n                  <jats:p>Well-baby nursery ward in a university hospital, tertiary referral centre.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results:<\/jats:title>\n                  <jats:p>The linear regression analysis showed a better correlation between BiliCheck and serum bilirubin (<jats:italic>r<\/jats:italic>\u200a=\u200a0.75) than between BiliMed and serum bilirubin (<jats:italic>r<\/jats:italic>\u200a=\u200a0.45). BiliCheck variability (\u00b12 SD of the mean bias from serum bilirubin) was within \u221287.2 to 63.3 \u03bcmol\/l, while BiliMed variability was within \u221297.5 to 121.4 \u03bcmol\/l. The receiver operating characteristic analysis (for serum bilirubin levels &gt;205.2 \u03bcmol\/l or &gt;239.4 \u03bcmol\/l) showed significantly higher areas under the curve for BiliCheck than those for BiliMed (p&lt;0.001).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions:<\/jats:title>\n                  <jats:p>Despite the potential practical advantages of BiliMed, its reduced diagnostic accuracy in comparison with BiliCheck does not justify its use in clinical practice.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/adc.2007.121053","type":"journal-article","created":{"date-parts":[[2007,11,15]],"date-time":"2007-11-15T20:45:09Z","timestamp":1195159509000},"page":"F135-F139","source":"Crossref","is-referenced-by-count":21,"title":["Attempt to improve transcutaneous bilirubinometry: a double-blind study of Medick BiliMed versus Respironics BiliCheck"],"prefix":"10.1136","volume":"93","author":[{"given":"D","family":"De Luca","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E","family":"Zecca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M","family":"Corsello","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E","family":"Tiberi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C","family":"Semeraro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C","family":"Romagnoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2007,11,15]]},"reference":[{"key":"2025090222015594000_93.2.F135.1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.114.1.e130"},{"key":"2025090222015594000_93.2.F135.2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.106.2.e17"},{"key":"2025090222015594000_93.2.F135.3","doi-asserted-by":"publisher","DOI":"10.1542\/peds.107.6.1264"},{"key":"2025090222015594000_93.2.F135.4","doi-asserted-by":"publisher","DOI":"10.1038\/sj.jp.7210592"},{"key":"2025090222015594000_93.2.F135.5","doi-asserted-by":"publisher","DOI":"10.1542\/peds.113.6.1636"},{"key":"2025090222015594000_93.2.F135.6","doi-asserted-by":"publisher","DOI":"10.1053\/siny.2002.0100"},{"key":"2025090222015594000_93.2.F135.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.earlhumdev.2006.06.006"},{"key":"2025090222015594000_93.2.F135.8","unstructured":"De Luca D Zecca E Zuppa AA . The joint use of human and electronic eye: visual assessment of jaundice and transcutaneous bilirubinometry. Turk J Pediatr (in press)."},{"key":"2025090222015594000_93.2.F135.9","unstructured":"Anonymous. BiliMed customer\u2019s information. Medick SA, Paris, France"},{"key":"2025090222015594000_93.2.F135.10","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1998.tb08183.x"},{"key":"2025090222015594000_93.2.F135.11","doi-asserted-by":"publisher","DOI":"10.1016\/0169-2607(95)01640-F"},{"key":"2025090222015594000_93.2.F135.12","first-page":"1","article-title":"Using a spectral reflectance technique to measure transcutaneous bilirubin in neonates: a new device.","volume":"33","author":"Ho","year":"2002","journal-title":"Issues Emerg Health Technol"},{"key":"2025090222015594000_93.2.F135.13","first-page":"159","article-title":"Standards antropometrici neonatali prodotti dalla task-force della Societ\u00e8 Italiana di Neonatologia e basati su una popolazione italiana nord-orientale [in Italian].","volume":"25","author":"Gagliardi","year":"1999","journal-title":"Riv Ital Pediatr"},{"key":"2025090222015594000_93.2.F135.14","doi-asserted-by":"publisher","DOI":"10.1542\/peds.114.1.297"},{"key":"2025090222015594000_93.2.F135.15","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1093\/clinchem\/48.7.1096","article-title":"Direct spectrophotometry method for measurement of bilirubin in newborns: comparison with HPLC and an automated diazo method.","volume":"48","author":"Kazmierczak","year":"2002","journal-title":"Clin Chem"},{"key":"2025090222015594000_93.2.F135.16","first-page":"771","article-title":"Non-invasive estimation of total serum bilirubin by multiwavelenght spectral reflectance in neonates.","volume":"37","author":"Lodha","year":"2000","journal-title":"Indian Pediatr"},{"key":"2025090222015594000_93.2.F135.17","doi-asserted-by":"publisher","DOI":"10.1016\/S0197-2456(97)00074-3"},{"key":"2025090222015594000_93.2.F135.18","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"2025090222015594000_93.2.F135.19","doi-asserted-by":"crossref","unstructured":"Simonoff S Jeffrey S . Smoothing methods in statistics. New York: Springer-Verlag, 1996:95\u2013104.","DOI":"10.1007\/978-1-4612-4026-6"},{"key":"2025090222015594000_93.2.F135.20","doi-asserted-by":"publisher","DOI":"10.1542\/neo.7-5-e217"},{"key":"2025090222015594000_93.2.F135.21","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2005-0590"}],"container-title":["Archives of Disease in Childhood - Fetal and Neonatal Edition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/adc.2007.121053","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,3]],"date-time":"2025-09-03T05:02:11Z","timestamp":1756875731000},"score":1,"resource":{"primary":{"URL":"https:\/\/fn.bmj.com\/lookup\/doi\/10.1136\/adc.2007.121053"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,11,15]]},"references-count":21,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2008,2,22]]},"published-print":{"date-parts":[[2008,3]]}},"alternative-id":["10.1136\/adc.2007.121053"],"URL":"https:\/\/doi.org\/10.1136\/adc.2007.121053","relation":{},"ISSN":["1359-2998","1468-2052"],"issn-type":[{"type":"print","value":"1359-2998"},{"type":"electronic","value":"1468-2052"}],"subject":[],"published":{"date-parts":[[2007,11,15]]}}}