{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T18:19:19Z","timestamp":1773166759148,"version":"3.50.1"},"reference-count":33,"publisher":"BMJ","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arch Dis Child Fetal Neonatal Ed"],"accepted":{"date-parts":[[2010,6,17]]},"published-print":{"date-parts":[[2012,1]]},"abstract":"<jats:p>Neonatal seizures are a distinct and not uncommon sign of neurological disease in the newborn, most often occurring in association with hypoxic-ischaemic encephalopathy at term. The diagnosis and monitoring of seizures in the newborn is a considerable challenge, with many suspected clinical seizures having no electrographic correlates, while many electrographic seizures have no clinical correlate. Continuous video-EEG is the gold standard for seizure monitoring, but few centres have the resources or expertise required. Amplitude-integrated EEG can be a helpful monitoring tool in experienced hands, but has potential for error when used by inexperienced staff. Automated seizure detection algorithms show much promise and some cotside systems are already available. The efficiency and accuracy of these systems is likely to improve.<\/jats:p>","DOI":"10.1136\/adc.2009.169508","type":"journal-article","created":{"date-parts":[[2010,8,5]],"date-time":"2010-08-05T22:09:21Z","timestamp":1281046161000},"page":"F65-F69","source":"Crossref","is-referenced-by-count":36,"title":["Monitoring of seizures in the newborn"],"prefix":"10.1136","volume":"97","author":[{"given":"Divyen K","family":"Shah","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geraldine B","family":"Boylan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janet M","family":"Rennie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2010,8,5]]},"reference":[{"key":"2025090511431221000_97.1.F65.1","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1159\/000109898","article-title":"Neonatal seizures in the United States: results of the National Hospital Discharge Survey, 1980-1991","volume":"15","author":"Lanska","year":"1996","journal-title":"Neuroepidemiology"},{"key":"2025090511431221000_97.1.F65.2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(99)70374-4"},{"key":"2025090511431221000_97.1.F65.3","unstructured":"Rennie JM . Neurological problems in the newborn: seizures. In: Rennie JM , ed. Roberton's textbook of neonatology. 4th edn. London: Elsevier Churchill Livingstone, 2005:1105\u00e2\u0080\u009319."},{"key":"2025090511431221000_97.1.F65.4","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1542\/peds.91.1.128","article-title":"Electrographic seizures in preterm and full-term neonates: clinical correlates, associated brain lesions, and risk for neurologic sequelae","volume":"91","author":"Scher","year":"1993","journal-title":"Pediatrics"},{"key":"2025090511431221000_97.1.F65.5","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1203\/00006450-200110000-00005","article-title":"Prolonged seizures exacerbate perinatal hypoxic-ischemic brain damage","volume":"50","author":"Wirrell","year":"2001","journal-title":"Pediatr Res"},{"key":"2025090511431221000_97.1.F65.6","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1212\/WNL.58.4.542","article-title":"Seizure-associated brain injury in term newborns with perinatal asphyxia","volume":"58","author":"Miller","year":"2002","journal-title":"Neurology"},{"key":"2025090511431221000_97.1.F65.7","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1212\/WNL.55.4.506","article-title":"Electrographic seizures in neonates correlate with poor neurodevelopmental outcome","volume":"55","author":"McBride","year":"2000","journal-title":"Neurology"},{"key":"2025090511431221000_97.1.F65.8","unstructured":"Volpe JJ . Neurology of the newborn. 5th edn. Philadelphia: WB Saunders, 2008."},{"key":"2025090511431221000_97.1.F65.9","doi-asserted-by":"publisher","DOI":"10.1136\/fn.86.3.F165"},{"key":"2025090511431221000_97.1.F65.10","doi-asserted-by":"publisher","DOI":"10.1016\/S0887-8994(02)00621-5"},{"key":"2025090511431221000_97.1.F65.11","doi-asserted-by":"publisher","DOI":"10.1017\/S0012162299001632"},{"key":"2025090511431221000_97.1.F65.12","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2005.086314"},{"key":"2025090511431221000_97.1.F65.13","doi-asserted-by":"publisher","DOI":"10.1016\/S0987-7053(03)00030-3"},{"key":"2025090511431221000_97.1.F65.14","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2007-1839"},{"key":"2025090511431221000_97.1.F65.15","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.4.5682.545"},{"key":"2025090511431221000_97.1.F65.16","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2008-1000"},{"key":"2025090511431221000_97.1.F65.17","doi-asserted-by":"crossref","unstructured":"Hellstrom-Westas L De Vries LS . Atlas of amplitude-integrated EEGs in the newborn. 2nd edn. London: Informa UK, 2008.","DOI":"10.3109\/9781439813898"},{"key":"2025090511431221000_97.1.F65.18","doi-asserted-by":"publisher","DOI":"10.1111\/j.1528-1157.1973.tb03975.x"},{"key":"2025090511431221000_97.1.F65.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2007.06.061"},{"key":"2025090511431221000_97.1.F65.20","doi-asserted-by":"publisher","DOI":"10.1136\/fn.89.1.F37"},{"key":"2025090511431221000_97.1.F65.21","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2007-0514"},{"key":"2025090511431221000_97.1.F65.22","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1111\/j.1651-2227.1992.tb12109.x","article-title":"Comparison between tape-recorded and amplitude-integrated EEG monitoring in sick newborn infants","volume":"81","author":"Hellstr\u00c3\u00b6m-Westas","year":"1992","journal-title":"Acta Paediatr"},{"key":"2025090511431221000_97.1.F65.23","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.2010.01809.x"},{"key":"2025090511431221000_97.1.F65.24","first-page":"45","article-title":"Automated seizure detection systems in the newborn","volume":"7","author":"Shah","year":"2009","journal-title":"J Pediatr Neurol"},{"key":"2025090511431221000_97.1.F65.25","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2008.02.001"},{"key":"2025090511431221000_97.1.F65.26","doi-asserted-by":"publisher","DOI":"10.1016\/0013-4694(92)90179-L"},{"key":"2025090511431221000_97.1.F65.27","doi-asserted-by":"publisher","DOI":"10.1016\/S0013-4694(97)00003-9"},{"key":"2025090511431221000_97.1.F65.28","doi-asserted-by":"publisher","DOI":"10.1109\/10.995684"},{"key":"2025090511431221000_97.1.F65.29","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2008.07.281"},{"key":"2025090511431221000_97.1.F65.30","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2006.02.016"},{"key":"2025090511431221000_97.1.F65.31","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpeds.2009.01.002"},{"key":"2025090511431221000_97.1.F65.32","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2008.156711"},{"key":"2025090511431221000_97.1.F65.33","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.clinph.2010.06.035","article-title":"Performance measures for neonatal seizure detectors","volume":"122","author":"Temko","year":"2010","journal-title":"Clin Neurophysiol"}],"container-title":["Archives of Disease in Childhood - Fetal and Neonatal Edition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/adc.2009.169508","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T18:59:43Z","timestamp":1757098783000},"score":1,"resource":{"primary":{"URL":"https:\/\/fn.bmj.com\/lookup\/doi\/10.1136\/adc.2009.169508"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,8,5]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2011,12,13]]},"published-print":{"date-parts":[[2012,1]]}},"alternative-id":["10.1136\/adc.2009.169508"],"URL":"https:\/\/doi.org\/10.1136\/adc.2009.169508","relation":{},"ISSN":["1359-2998","1468-2052"],"issn-type":[{"value":"1359-2998","type":"print"},{"value":"1468-2052","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,8,5]]}}}