{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T10:03:23Z","timestamp":1769162603535,"version":"3.49.0"},"reference-count":22,"publisher":"BMJ","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Archives of Disease in Childhood"],"published-print":{"date-parts":[[1991,6,1]]},"DOI":"10.1136\/adc.66.6.676","type":"journal-article","created":{"date-parts":[[2008,12,22]],"date-time":"2008-12-22T22:39:16Z","timestamp":1229985556000},"page":"676-682","source":"Crossref","is-referenced-by-count":38,"title":["Home monitoring of transcutaneous oxygen tension in the early detection of hypoxaemia in infants and young children."],"prefix":"10.1136","volume":"66","author":[{"given":"C F","family":"Poets","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M P","family":"Samuels","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J P","family":"Noyes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K A","family":"Jones","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D P","family":"Southall","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1542\/peds.77.4.451","article-title":"Sudden infant death syndrome in infants evaluated by apnea programs in California","volume":"77","author":"SL, Davidson Ward; TG, Keens; LS, Chan","year":"1986","unstructured":"Davidson Ward SL, Keens TG, Chan LS, et al. Sudden infant death syndrome in infants evaluated by apnea programs in California. Pediatrics 1986;77:451-8.","journal-title":"Pediatrics"},{"key":"ref_2","first-page":"21","article-title":"Pneumographic studies: predictors of future apnoeas but not sudden infant death in asymptomatic infants","volume":"25","author":"Rahilly, P.M.","year":"1989","unstructured":"Rahilly PM. Pneumographic studies: predictors of future apnoeas but not sudden infant death in asymptomatic infants. Aust Paediatr J 1989;25:21 1-4.","journal-title":"Aust Paediatr J"},{"key":"ref_3","first-page":"304","article-title":"Home monitoring in Hawaii: the first 1,000 patients","volume":"48","author":"Light, M.J.; Sheridan, M.S.","year":"1989","unstructured":"Light MJ, Sheridan MS. Home monitoring in Hawaii: the first 1,000 patients. Hawaii Med J 1989;48:304-27.","journal-title":"Hawaii Med J"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1136\/adc.65.9.953","article-title":"Recurrent cyanotic episodes with severe arterial hypoxaemia and intrapulmonary shunting: a mechanism for sudden death","volume":"65","author":"Southall, D.P.; Samuels, M.P.; Talbert, D.G.","year":"1990","unstructured":"Southall DP, Samuels MP, Talbert DG. Recurrent cyanotic episodes with severe arterial hypoxaemia and intrapulmonary shunting: a mechanism for sudden death. Arch Dis Child 1990;65:953-61.","journal-title":"Arch Dis Child"},{"key":"ref_5","first-page":"73","article-title":"Role of apnea in the sudden infant death syndrome: a personal view","volume":"81","author":"Southall, D.P.","year":"1988","unstructured":"Southall DP. Role of apnea in the sudden infant death syndrome: a personal view. Pediatrics 1988;81:73-84.","journal-title":"Pediatrics"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1136\/adc.62.9.882","article-title":"Pulse oximeter and transcutaneous arterial oxygen measurements in neonatal and paediatric intensive care","volume":"62","author":"Southall, D.P.; Bignall, S.; Stebbens, V.A.","year":"1987","unstructured":"Southall DP, Bignall S, Stebbens VA, et al. Pulse oximeter and transcutaneous arterial oxygen measurements in neonatal and paediatric intensive care. Arch Dis Child 1987; 62:882-8.","journal-title":"Arch Dis Child"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0065-3101(22)00634-X","article-title":"Clinical uses of transcutaneous oxygen monitoring","volume":"28","author":"Lucey, J.F.","year":"1981","unstructured":"Lucey JF. Clinical uses of transcutaneous oxygen monitoring. Adv Pediatr 1981;28:27-56.","journal-title":"Adv Pediatr"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1542\/peds.64.6.892","article-title":"The influence of different electrode temperatures on the recorded transcutaneous PO2 level","volume":"64","author":"Lofgren 0, Jacobson L","year":"1979","unstructured":"Lofgren 0, Jacobson L. The influence of different electrode temperatures on the recorded transcutaneous PO2 level. Pediatrics 1979;64:892-7.","journal-title":"Pediatrics"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1136\/bmj.299.6710.1253","article-title":"Negative extrathoracic pressure in treatment of respiratory failure in infants and young children","volume":"299","author":"Samuels, M.P.; Southall, D.P.","year":"1989","unstructured":"Samuels MP, Southall DP. Negative extrathoracic pressure in treatment of respiratory failure in infants and young children. BMJ 1989;299:1253-7.","journal-title":"BMJ"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/S0022-3476(89)80694-8","article-title":"Sudden infant death syndrome and birth weight","volume":"114","author":"Grether, J.K.; Schulman, J.","year":"1989","unstructured":"Grether JK, Schulman J. Sudden infant death syndrome and birth weight. J Pediatr 1989;114:561-7.","journal-title":"J Pediatr"},{"key":"ref_11","first-page":"155","article-title":"Skin blood flow changes during apneic spells in preterm infants. Early Hum Dev 1989; 20","author":"Suichies, H.E.; Aarnoudse, J.G.; Okken, A.; Jentink, H.W.; de Mul, F.F.M.; Greve, J.","unstructured":"Suichies HE, Aarnoudse JG, Okken A, Jentink HW, de Mul FFM, Greve J. Skin blood flow changes during apneic spells in preterm infants. Early Hum Dev 1989;20:155-63."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1111\/j.1399-6576.1978.tb01388.x","article-title":"Reliability of cutaneous oxygen measurement by skin sensors with large-size cathodes","volume":"68","author":"Eberhard, P.; Mindt, W.","year":"1978","unstructured":"Eberhard P, Mindt W. Reliability of cutaneous oxygen measurement by skin sensors with large-size cathodes. Acta Anaesthesiol Scand 1978;68(suppl):20-7.","journal-title":"Acta Anaesthesiol Scand"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1542\/peds.65.3.515","article-title":"Effect of electrode temperature and in vivo calibration on accuracy of transcutaneous estimation of arterial oxygen tension in infants","volume":"65","author":"Pollitzer, M.J.; Whitehead, M.D.; Reynolds, E.O.R.; Delpy, D.","year":"1980","unstructured":"Pollitzer MJ, Whitehead MD, Reynolds EOR, Delpy D. Effect of electrode temperature and in vivo calibration on accuracy of transcutaneous estimation of arterial oxygen tension in infants. Pediatrics 1980;65:515-22.","journal-title":"Pediatrics"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/S0022-3476(85)80507-2","article-title":"Pulse oximetry in pediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension","volume":"107","author":"Fanconi, S.; Doherty, P.; Edmonds, J.F.","year":"1985","unstructured":"Fanconi S, Doherty P, Edmonds JF, et al. Pulse oximetry in pediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension. J Pediatr 1985; 107:362-6.","journal-title":"J Pediatr"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1542\/peds.65.2.203","article-title":"Excessive handling as a cause of hypoxemia","volume":"65","author":"Long, J.G.; Philip, A.G.S.; Lucey, J.F.","year":"1980","unstructured":"Long JG, Philip AGS, Lucey JF. Excessive handling as a cause of hypoxemia. Pediatrics 1980;65:203-7.","journal-title":"Pediatrics"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/0378-3782(90)90090-6","article-title":"Patterns of breathing during hypoxaemia in preterm infants at around term (abstract)","volume":"22","author":"Poets, C.F.; Stebbens, V.A.; Samuels, M.P.; Southall, D.P.","year":"1990","unstructured":"Poets CF, Stebbens VA, Samuels MP, Southall DP. Patterns of breathing during hypoxaemia in preterm infants at around term (abstract). Early Hum Dev 1990;22:107-8.","journal-title":"Early Hum Dev"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1007\/BF02343224","article-title":"Impact of home monitoring for sudden infant death syndrome on family life","volume":"146","author":"Desmarez, C.; Blum, D.; Montauk, L.; Kahn, A.","year":"1987","unstructured":"Desmarez C, Blum D, Montauk L, Kahn A. Impact of home monitoring for sudden infant death syndrome on family life. Eur J Pediatr 1987;146:159-61.","journal-title":"Eur J Pediatr"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/S0022-3476(89)80645-6","article-title":"Assessing validity of infant monitor alarms with event recording","volume":"115","author":"Weese-Mayer, D.E.; Brouillette, R.T.; Morrow, A.S.","year":"1989","unstructured":"Weese-Mayer DE, Brouillette RT, Morrow AS, et al. Assessing validity of infant monitor alarms with event recording. Jf Pediatr 1989;115:702-8.","journal-title":"Jf Pediatr"},{"key":"ref_19","first-page":"292","article-title":"National Institutes of Health consensus development conference on infantile apnea and home monitoring, Sept 29 to","volume":"79","author":"Little, G.A.; Ballard, R.A.; Brooks, J.G.","year":"1986","unstructured":"Little GA, Ballard RA, Brooks JG, et al. National Institutes of Health consensus development conference on infantile apnea and home monitoring, Sept 29 to Oct 1, 1986. Pediatnrcs 1987;79:292-9.","journal-title":"Pediatnrcs"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/S0022-3476(84)81093-8","article-title":"Prospective assessment of recurrence risk in sudden infant death syndrome siblings","volume":"104","year":"1984","unstructured":"Irgens LM, Skjaerven R, Peterson DR. Prospective assessment of recurrence risk in sudden infant death syndrome siblings. J Pediatr 1984;104:349-51.","journal-title":"J Pediatr"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1016\/S0022-3476(05)81596-3","article-title":"Risk of sudden infant death syndrome in subsequent siblings","volume":"116","author":"Guntheroth, W.G.; Lohmann, R.; Spiers, P.S.","year":"1990","unstructured":"Guntheroth WG, Lohmann R, Spiers PS. Risk of sudden infant death syndrome in subsequent siblings. Jf Pediatr 1990;116:520-4.","journal-title":"Jf Pediatr"},{"key":"ref_22","first-page":"181","article-title":"Pulse oximetry and transcutaneous oxygen tension in hypoxemic neonates and infants with bronchopulmonary dysplasia","volume":"220","author":"Lafeber, H.N.; Fetter, W.P.F.; van der Wiel, A.R.; Jansen, T.C.","year":"1987","unstructured":"Lafeber HN, Fetter WPF, van der Wiel AR, Jansen TC. Pulse oximetry and transcutaneous oxygen tension in hypoxemic neonates and infants with bronchopulmonary dysplasia. Adv Exp Med Biol 1987;220:181-6.","journal-title":"Adv Exp Med Biol"}],"container-title":["Archives of Disease in Childhood"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/adc.66.6.676","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,23]],"date-time":"2023-05-23T03:52:46Z","timestamp":1684813966000},"score":1,"resource":{"primary":{"URL":"https:\/\/adc.bmj.com\/lookup\/doi\/10.1136\/adc.66.6.676"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1991,6,1]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1991,6,1]]}},"URL":"https:\/\/doi.org\/10.1136\/adc.66.6.676","relation":{},"ISSN":["0003-9888","1468-2044"],"issn-type":[{"value":"0003-9888","type":"print"},{"value":"1468-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[1991,6,1]]}}}