{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T15:47:34Z","timestamp":1781279254214,"version":"3.54.1"},"reference-count":22,"publisher":"BMJ","issue":"4","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Arch Dis Child Fetal Neonatal Ed"],"accepted":{"date-parts":[[2014,2,20]]},"published-print":{"date-parts":[[2014,7]]},"abstract":"<jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>Noise exposure in the neonatal intensive care unit is believed to be a risk factor for hearing loss in preterm neonates. Continuous positive airway pressure (CPAP) devices exceed recommended noise levels. High flow nasal cannulae (HFNC) are an increasingly popular alternative to CPAP for treating preterm infants, but there are no in vivo studies assessing noise production by HFNC.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>To study whether HFNC are noisier than bubble CPAP (BCPAP) for preterm infants.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>An observational study of preterm infants receiving HFNC or BCPAP. Noise levels within the external auditory meatus (EAM) were measured using a microphone probe tube connected to a calibrated digital dosimeter. Noise was measured across a range of frequencies and reported as decibels A-weighted (dBA).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>A total of 21 HFNC and 13 BCPAP noise measurements were performed in 21 infants. HFNC gas flows were 2\u20135\u2005L\/min, and BCPAP gas flows were 6\u201310\u2005L\/min with set pressures of 5\u20137\u2005cm of water. There was no evidence of a difference in average noise levels measured at the EAM: mean difference (95% CI) of \u22121.6 (\u22124.0 to 0.9) dBA for HFNC compared to BCPAP. At low frequency (500\u2005Hz), HFNC was mean (95% CI) 3.0 (0.3 to 5.7) dBA quieter than BCPAP. Noise increased with increasing BCPAP gas flow (p=0.007), but not with increasing set pressure. There was a trend to noise increasing with increasing HFNC gas flows.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>At the gas flows studied, HFNC are not noisier than BCPAP for preterm infants.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/archdischild-2013-305033","type":"journal-article","created":{"date-parts":[[2014,3,14]],"date-time":"2014-03-14T00:26:59Z","timestamp":1394756819000},"page":"F291-F296","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":17,"title":["Are high flow nasal cannulae noisier than bubble CPAP for preterm infants?"],"prefix":"10.1136","volume":"99","author":[{"given":"C T","family":"Roberts","sequence":"first","affiliation":[{"name":"Newborn Research Centre, The Royal Women's Hospital, Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J A","family":"Dawson","sequence":"additional","affiliation":[{"name":"Newborn Research Centre, The Royal Women's Hospital, Melbourne, Australia"},{"name":"Department of Obstetrics and Gynaecology, The University of Melbourne, Melbourne, Australia"},{"name":"Critical Care and Neurosciences, Murdoch Children's Research Institute, Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E","family":"Alquoka","sequence":"additional","affiliation":[{"name":"Department of Audiology and Speech Pathology, The University of Melbourne, Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P J","family":"Carew","sequence":"additional","affiliation":[{"name":"Department of Audiology and Speech Pathology, The University of Melbourne, Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S M","family":"Donath","sequence":"additional","affiliation":[{"name":"Clinical Epidemiology and Biostatistics Unit, Murdoch Children's Research Institute, Melbourne, Australia"},{"name":"Department of Paediatrics, The University of Melbourne, Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P G","family":"Davis","sequence":"additional","affiliation":[{"name":"Newborn Research Centre, The Royal Women's Hospital, Melbourne, Australia"},{"name":"Department of Obstetrics and Gynaecology, The University of Melbourne, Melbourne, Australia"},{"name":"Critical Care and Neurosciences, Murdoch Children's Research Institute, Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B J","family":"Manley","sequence":"additional","affiliation":[{"name":"Newborn Research Centre, The Royal Women's Hospital, Melbourne, Australia"},{"name":"Department of Obstetrics and Gynaecology, The University of Melbourne, Melbourne, Australia"},{"name":"Critical Care and Neurosciences, Murdoch Children's Research Institute, Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2014,3,13]]},"reference":[{"key":"2025090512442759000_99.4.F291.1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2008-2531"},{"key":"2025090512442759000_99.4.F291.2","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1016\/S0140-6736(76)91088-6","article-title":"Effects of incubator noise on the cochlea of the newborn","volume":"2","author":"Douek","year":"1976","journal-title":"Lancet"},{"key":"2025090512442759000_99.4.F291.3","doi-asserted-by":"publisher","DOI":"10.1288\/00005537-197403000-00008"},{"key":"2025090512442759000_99.4.F291.4","doi-asserted-by":"publisher","DOI":"10.1289\/ehp.824463"},{"key":"2025090512442759000_99.4.F291.5","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2009.182014"},{"key":"2025090512442759000_99.4.F291.6","doi-asserted-by":"crossref","unstructured":"Philbin MK . Planning the acoustic environment of a neonatal intensive care unit. Clin Perinatol 2004;31:331\u201352, viii.","DOI":"10.1016\/j.clp.2004.04.014"},{"key":"2025090512442759000_99.4.F291.7","doi-asserted-by":"publisher","DOI":"10.1542\/peds.100.4.724"},{"key":"2025090512442759000_99.4.F291.8","doi-asserted-by":"crossref","unstructured":"Krueger C Horesh E Crossland BA . Safe sound exposure in the fetus and preterm infant. J Obstet Gynecol Neonatal Nurs 2012;41:166\u201370.","DOI":"10.1111\/j.1552-6909.2012.01342.x"},{"key":"2025090512442759000_99.4.F291.9","doi-asserted-by":"publisher","DOI":"10.1121\/1.2717500"},{"key":"2025090512442759000_99.4.F291.10","doi-asserted-by":"publisher","DOI":"10.1159\/000329558"},{"key":"2025090512442759000_99.4.F291.11","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2010.02356.x"},{"key":"2025090512442759000_99.4.F291.12","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2007.129098"},{"key":"2025090512442759000_99.4.F291.13","doi-asserted-by":"publisher","DOI":"10.1136\/fn.88.4.F315"},{"key":"2025090512442759000_99.4.F291.14","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1754.2011.02070.x"},{"key":"2025090512442759000_99.4.F291.15","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1754.2011.02186.x"},{"key":"2025090512442759000_99.4.F291.16","doi-asserted-by":"publisher","DOI":"10.1111\/apa.12090"},{"key":"2025090512442759000_99.4.F291.17","doi-asserted-by":"publisher","DOI":"10.1159\/000346764"},{"key":"2025090512442759000_99.4.F291.18","doi-asserted-by":"publisher","DOI":"10.1590\/S0104-11692011000100028"},{"key":"2025090512442759000_99.4.F291.19","unstructured":"Chow SSW . Report of the Australian and New Zealand Neonatal Network 2010. Sydney : ANZNN, 2013."},{"key":"2025090512442759000_99.4.F291.20","doi-asserted-by":"publisher","DOI":"10.3109\/01050399709074979"},{"key":"2025090512442759000_99.4.F291.21","doi-asserted-by":"publisher","DOI":"10.1177\/000348947108000616"},{"key":"2025090512442759000_99.4.F291.22","first-page":"448","article-title":"Premature infant responses to noise reduction by earmuffs: effects on behavioral and physiologic measures","volume":"15","author":"Zahr","year":"1995","journal-title":"J Perinatol"}],"container-title":["Archives of Disease in Childhood - Fetal and Neonatal Edition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/archdischild-2013-305033","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T19:44:37Z","timestamp":1757101477000},"score":1,"resource":{"primary":{"URL":"https:\/\/fn.bmj.com\/lookup\/doi\/10.1136\/archdischild-2013-305033"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3,13]]},"references-count":22,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2014,6,12]]},"published-print":{"date-parts":[[2014,7]]}},"alternative-id":["10.1136\/archdischild-2013-305033"],"URL":"https:\/\/doi.org\/10.1136\/archdischild-2013-305033","relation":{},"ISSN":["1359-2998","1468-2052"],"issn-type":[{"value":"1359-2998","type":"print"},{"value":"1468-2052","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,3,13]]}}}