{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T02:27:53Z","timestamp":1791167273278,"version":"4.1.0"},"reference-count":22,"publisher":"BMJ","issue":"4","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Arch Dis Child Fetal Neonatal Ed"],"accepted":{"date-parts":[[2018,8,10]]},"published-print":{"date-parts":[[2019,7]]},"abstract":"<jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>High-frequency oscillatory ventilation (HFOV) is widely used in neonatology. The Dr\u00e4ger Babylog VN500 ventilator offers volume-guaranteed HFOV (HFOV-VG) mode when the high-frequency tidal volume (VThf) to be delivered can be set. We investigated how HFOV-VG maintains VThf in the short and longer term and how it affects other ventilator parameters and blood gases.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>We downloaded ~3.2\u2009million seconds (36.7 days) of ventilator data from 17 infants ventilated using HFOV-VG during clinical care with 1\u2009Hz sampling rate. To process and analyse the data, we used the Python computer language.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Overall, the median VThf was 1.93\u2009mL\/kg (IQR 1.64\u20132.45\u2009mL\/kg). The difference between set and delivered tidal volume was &lt;0.2\u2009mL\/kg for 83% of time. In the individual recordings, the median VThf ranged between 1.44 and 3.31\u2009mL\/kg. During HFOV-VG, the VThf varied from 1 second to another, but it was very close to the target value when averaged over 5\u2009min periods. After weight correction, the VThf or the diffusion coefficient of carbon dioxide (DCO<jats:sub>2<\/jats:sub>) showed weak inverse correlation with partial pressure of CO<jats:sub>2<\/jats:sub>(pCO<jats:sub>2<\/jats:sub>) (for VThf, r=\u22120.162, 95% CI \u22120.282 to \u20130.037, p=0.01). Uncorrected values showed no correlation. Of the 53 blood gas measurements taken when VThf was &gt;2.5\u2009mL\/kg, there were only six (11%) with a pCO<jats:sub>2<\/jats:sub> &gt;8\u2009kPa.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>During HFOV-VG, the tidal volume of oscillations varies in the short term but is maintained very close to the target over the longer term. VThf or DCO<jats:sub>2<\/jats:sub> have poor correlation with CO<jats:sub>2<\/jats:sub> levels but a volume of &gt;2.5\u2009mL\/kg VThf is rarely needed.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/archdischild-2018-315490","type":"journal-article","created":{"date-parts":[[2018,9,14]],"date-time":"2018-09-14T12:36:53Z","timestamp":1536928613000},"page":"F384-F389","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":18,"title":["High-frequency oscillatory ventilation with volume guarantee: a single-centre experience"],"prefix":"10.1136","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2974-2011","authenticated-orcid":false,"given":"Gusztav","family":"Belteki","sequence":"first","affiliation":[{"name":"Neonatal Intensive Care Unit, The Rosie Hospital, Cambridge University Hospitals NHS Trust, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Colin J","family":"Morley","sequence":"additional","affiliation":[{"name":"Neonatal Intensive Care Unit, The Rosie Hospital, Cambridge University Hospitals NHS Trust, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,9,14]]},"reference":[{"key":"2025090510254876000_104.4.F384.1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1309220"},{"key":"2025090510254876000_104.4.F384.2","first-page":"CD000104","article-title":"Elective high frequency oscillatory ventilation versus conventional ventilation for acute pulmonary dysfunction in preterm infants","volume":"3","author":"Cools","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"2025090510254876000_104.4.F384.3","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1080\/03091900601087898","article-title":"A review of high frequency oscillation ventilation in the neonate","volume":"31","author":"Wheeler","year":"2007","journal-title":"J Med Eng Technol"},{"key":"2025090510254876000_104.4.F384.4","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1038\/jp.2014.39","article-title":"Bringing back the old: time to reevaluate the high-frequency ventilation strategy","volume":"34","author":"Mukerji","year":"2014","journal-title":"J Perinatol"},{"key":"2025090510254876000_104.4.F384.5","doi-asserted-by":"publisher","DOI":"10.1186\/cc3988"},{"key":"2025090510254876000_104.4.F384.6","doi-asserted-by":"publisher","DOI":"10.1186\/cc4968"},{"key":"2025090510254876000_104.4.F384.7","doi-asserted-by":"crossref","first-page":"2364","DOI":"10.1152\/jappl.1989.66.5.2364","article-title":"Chest wall restriction limits high airway pressure-induced lung injury in young rabbits","volume":"66","author":"Hernandez","year":"1989","journal-title":"J Appl Physiol"},{"key":"2025090510254876000_104.4.F384.8","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200701-051OC"},{"key":"2025090510254876000_104.4.F384.9","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1159\/000437204","article-title":"Impact of volume\u00a0guarantee on high-frequency oscillatory ventilation in preterm\u00a0infants: a randomized crossover clinical trial","volume":"108","author":"Iscan","year":"2015","journal-title":"Neonatology"},{"key":"2025090510254876000_104.4.F384.10","first-page":"26","article-title":"Effect of volume guarantee in preterm infants on high-frequency oscillatory ventilation: a pilot study","volume":"34","author":"Enomoto","year":"2017","journal-title":"Am J Perinatol"},{"key":"2025090510254876000_104.4.F384.11","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2017-313493"},{"key":"2025090510254876000_104.4.F384.12","doi-asserted-by":"publisher","DOI":"10.1002\/ppul.1091"},{"key":"2025090510254876000_104.4.F384.13","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1002\/ppul.23759","article-title":"Weight-correction of carbon dioxide diffusion coefficient (DCO2) reduces its inter-individual variability and improves its correlation with blood carbon dioxide levels in neonates receiving high-frequency oscillatory ventilation","volume":"52","author":"Belteki","year":"2017","journal-title":"Pediatr Pulmonol"},{"key":"2025090510254876000_104.4.F384.14","doi-asserted-by":"crossref","unstructured":"S\u00e1nchez Luna M , Santos Gonz\u00e1lez M , Tendillo Cortijo F . High-frequency oscillatory ventilation combined with volume guarantee in a neonatal animal model of respiratory distress syndrome. Crit Care Res Pract 2013;2013.doi:10.1155\/2013\/593915","DOI":"10.1155\/2013\/593915"},{"key":"2025090510254876000_104.4.F384.15","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1007\/s00431-016-2770-2","article-title":"Effect of the I\/E ratio on CO2 removal during high-frequency oscillatory ventilation with volume guarantee in a neonatal animal model of RDS","volume":"175","author":"S\u00e1nchez-Luna","year":"2016","journal-title":"Eur J Pediatr"},{"key":"2025090510254876000_104.4.F384.16","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1038\/jp.2015.197","article-title":"Using very high frequencies with very low lung volumes during high-frequency oscillatory ventilation to protect the immature lung. A pilot study","volume":"36","author":"Gonz\u00e1lez-Pacheco","year":"2016","journal-title":"J Perinatol"},{"key":"2025090510254876000_104.4.F384.17","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1152\/jappl.1989.66.3.1343","article-title":"Gas exchange in healthy rabbits during high-frequency oscillatory ventilation","volume":"66","author":"Boynton","year":"1989","journal-title":"J Appl Physiol"},{"key":"2025090510254876000_104.4.F384.18","doi-asserted-by":"publisher","DOI":"10.1097\/01.CCM.0000155789.52984.B7"},{"key":"2025090510254876000_104.4.F384.19","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2015-309636"},{"key":"2025090510254876000_104.4.F384.20","doi-asserted-by":"crossref","first-page":"101","DOI":"10.3349\/ymj.2018.59.1.101","article-title":"Effective tidal volume for normocapnia in very low-birth-weight infants using high-frequency\u00a0oscillatory ventilation","volume":"59","author":"Lee","year":"2018","journal-title":"Yonsei Med J"},{"key":"2025090510254876000_104.4.F384.21","doi-asserted-by":"publisher","DOI":"10.1159\/000326080"},{"key":"2025090510254876000_104.4.F384.22","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200205000-00011"}],"container-title":["Archives of Disease in Childhood - Fetal and Neonatal Edition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/archdischild-2018-315490","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T17:44:46Z","timestamp":1757094286000},"score":1,"resource":{"primary":{"URL":"https:\/\/fn.bmj.com\/lookup\/doi\/10.1136\/archdischild-2018-315490"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,14]]},"references-count":22,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,6,19]]},"published-print":{"date-parts":[[2019,7]]}},"alternative-id":["10.1136\/archdischild-2018-315490"],"URL":"https:\/\/doi.org\/10.1136\/archdischild-2018-315490","relation":{},"ISSN":["1359-2998","1468-2052"],"issn-type":[{"value":"1359-2998","type":"print"},{"value":"1468-2052","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,14]]}}}