{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T14:31:29Z","timestamp":1784989889736,"version":"3.55.0"},"reference-count":27,"publisher":"BMJ","issue":"5","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Arch Dis Child Fetal Neonatal Ed"],"accepted":{"date-parts":[[2018,11,26]]},"published-print":{"date-parts":[[2019,9]]},"abstract":"<jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>To compare the resistance of interfaces used for the delivery of nasal continuous positive airway pressure (CPAP) in neonates, as measured by the generated system pressure at fixed gas flows, in an in vitro setting.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Design<\/jats:title>\n                  <jats:p>Gas flows of 6, 8 and 10 L\/min were passed through three sizes of each of a selection of available neonatal nasal CPAP interfaces (Hudson prong, RAM Cannula, Fisher &amp; Paykel prong, Infant Flow prong, Fisher &amp; Paykel mask, Infant Flow mask). The expiratory limb was occluded and pressure differential measured using a calibrated pressure transducer.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Variation in resistance, assessed by mean pressure differential, was seen between CPAP interfaces. Binasal prong interfaces typically had greater resistance at the smallest assessed sizes, and with higher gas flows. However, Infant Flow prongs produced low pressures (&lt;1.5\u2009cmH<jats:sub>2<\/jats:sub>O) at all sizes and gas flows. RAM Cannula had a high resistance, producing a pressure &gt;4.5\u2009cmH<jats:sub>2<\/jats:sub>O at all sizes and gas flows. Both nasal mask interfaces had low resistance at all assessed sizes and gas flows, with recorded pressure &lt;1\u2009cmH<jats:sub>2<\/jats:sub>O in all cases.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>There is considerable variation in measured resistance of available CPAP interfaces at gas flows commonly applied in clinical neonatal care. Use of interfaces with high resistance may result in a greater drop in delivered airway pressure in comparison to set circuit pressure, which may have implications for clinical efficacy. Device manufacturers and clinicians should consider CPAP interface resistance prior to introduction into routine clinical care.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/archdischild-2018-315838","type":"journal-article","created":{"date-parts":[[2018,12,19]],"date-time":"2018-12-19T17:15:25Z","timestamp":1545239725000},"page":"F535-F539","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":45,"title":["Assessment of resistance of nasal continuous positive airway pressure interfaces"],"prefix":"10.1136","volume":"104","author":[{"given":"Elys Alexandra","family":"Green","sequence":"first","affiliation":[{"name":"Monash Newborn, Monash Medical Centre, Clayton, Victoria, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer Anne","family":"Dawson","sequence":"additional","affiliation":[{"name":"Newborn Research and Neonatal Services, The Royal Women\u2019s Hospital, Parkville, Victoria, Australia"},{"name":"Department of Obstetrics and Gynaecology, University of Melbourne, Parkville, Victoria, Australia"},{"name":"Murdoch Children\u2019s Research Institute, Melbourne, Victoria, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter G","family":"Davis","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, University of Melbourne, Parkville, Victoria, Australia"},{"name":"Murdoch Children\u2019s Research Institute, Melbourne, Victoria, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio G","family":"De Paoli","sequence":"additional","affiliation":[{"name":"Department of Paediatrics, Royal Hobart Hospital, Hobart, Tasmania, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9111-5027","authenticated-orcid":false,"given":"Calum Timothy","family":"Roberts","sequence":"additional","affiliation":[{"name":"Monash Newborn, Monash Medical Centre, Clayton, Victoria, Australia"},{"name":"Newborn Research and Neonatal Services, The Royal Women\u2019s Hospital, Parkville, Victoria, Australia"},{"name":"Department of Paediatrics, Monash University, Melbourne, Victoria, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,12,19]]},"reference":[{"key":"2025090512083460000_104.5.F535.1","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.siny.2016.02.009","article-title":"Continuous positive airway pressure: physiology and comparison of devices","volume":"21","author":"Gupta","year":"2016","journal-title":"Semin Fetal Neonatal Med"},{"key":"2025090512083460000_104.5.F535.2","doi-asserted-by":"crossref","unstructured":"Davis PG , Henderson-Smart DJ . Nasal continuous positive airways pressure immediately after extubation for preventing morbidity in preterm infants. Cochrane Database Syst Rev 2003:CD000143.doi:10.1002\/14651858.CD000143","DOI":"10.1002\/14651858.CD000143"},{"key":"2025090512083460000_104.5.F535.3","doi-asserted-by":"crossref","unstructured":"De Paoli AG , Davis PG , Faber B , et al . Devices and pressure sources for administration of nasal continuous positive airway pressure (NCPAP) in preterm neonates. Cochrane Database Syst Rev 2008:CD002977.doi:10.1002\/14651858.CD002977.pub2","DOI":"10.1002\/14651858.CD002977.pub2"},{"key":"2025090512083460000_104.5.F535.4","unstructured":"Chow SSW LMR , Creighton P , Kander V , et al . Report of the Australian and New Zealand Neonatal Network 2015. Sydney: ANZNN 2017."},{"key":"2025090512083460000_104.5.F535.5","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1159\/000448985","article-title":"European consensus guidelines on the management of respiratory distress syndrome - 2016 update","volume":"111","author":"Sweet","year":"2017","journal-title":"Neonatology"},{"key":"2025090512083460000_104.5.F535.6","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2013-3442"},{"key":"2025090512083460000_104.5.F535.7","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2017-313418"},{"key":"2025090512083460000_104.5.F535.8","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2004.052274"},{"key":"2025090512083460000_104.5.F535.9","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2007.120428"},{"key":"2025090512083460000_104.5.F535.10","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198001000-00007"},{"key":"2025090512083460000_104.5.F535.11","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1152\/jappl.1999.87.1.36","article-title":"Estimation of inspiratory pressure drop in neonatal and pediatric endotracheal tubes","volume":"87","author":"Jarreau","year":"1999","journal-title":"J Appl Physiol"},{"key":"2025090512083460000_104.5.F535.12","doi-asserted-by":"publisher","DOI":"10.1136\/fn.87.1.F42"},{"key":"2025090512083460000_104.5.F535.13","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.04251"},{"key":"2025090512083460000_104.5.F535.14","doi-asserted-by":"crossref","first-page":"41","DOI":"10.2174\/1874306401711010041","article-title":"Use of nasal non-invasive ventilation with a RAM Cannula in the Outpatient Home Setting","volume":"11","author":"De Jesus Rojas","year":"2017","journal-title":"Open Respir Med J"},{"key":"2025090512083460000_104.5.F535.15","doi-asserted-by":"publisher","DOI":"10.1002\/ppul.23197"},{"key":"2025090512083460000_104.5.F535.16","doi-asserted-by":"crossref","first-page":"718","DOI":"10.3109\/14767058.2014.929659","article-title":"Systematic use of the RAM nasal cannula in the Yale-New Haven Children\u2019s Hospital Neonatal Intensive Care Unit: a quality improvement project","volume":"28","author":"Nzegwu","year":"2015","journal-title":"J Matern Fetal Neonatal Med"},{"key":"2025090512083460000_104.5.F535.17","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.03438"},{"key":"2025090512083460000_104.5.F535.18","doi-asserted-by":"publisher","DOI":"10.1093\/tropej\/fmv088"},{"key":"2025090512083460000_104.5.F535.19","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2008.148981"},{"key":"2025090512083460000_104.5.F535.20","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1007\/s13312-015-0769-9","article-title":"Nasal mask versus nasal prongs for delivering nasal continuous positive airway pressure in preterm infants with respiratory distress: a randomized controlled trial","volume":"52","author":"Goel","year":"2015","journal-title":"Indian Pediatr"},{"key":"2025090512083460000_104.5.F535.21","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2011-3548"},{"key":"2025090512083460000_104.5.F535.22","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2010.203190"},{"key":"2025090512083460000_104.5.F535.23","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1159\/000443263","article-title":"Binasal prong versus nasal mask for applying CPAP to preterm infants: a randomized controlled trial","volume":"109","author":"Say","year":"2016","journal-title":"Neonatology"},{"key":"2025090512083460000_104.5.F535.24","doi-asserted-by":"crossref","first-page":"21409","DOI":"10.18535\/jmscr\/v5i5.32","article-title":"To study effectiveness of nasal prong and nasal mask in nasal continuous positive airway pressure in preterm neonates with respiratory distress","volume":"05","author":"Kumar","year":"2017","journal-title":"Journal of Medical Science And clinical Research"},{"key":"2025090512083460000_104.5.F535.25","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s00431-017-2851-x","article-title":"Nasal masks or binasal prongs for delivering continuous positive airway pressure in preterm neonates-a randomised trial","volume":"176","author":"Chandrasekaran","year":"2017","journal-title":"Eur J Pediatr"},{"key":"2025090512083460000_104.5.F535.26","doi-asserted-by":"crossref","unstructured":"Jasani B IA , Rao S , Patole S . Effectiveness and safety of nasal mask versus binasal prongs for providing continuous positive airway pressure in preterm infants\u2014a systematic review and meta-analysis. Pediatric Pulmonology 2018:1\u20136.","DOI":"10.1002\/ppul.24014"},{"key":"2025090512083460000_104.5.F535.27","doi-asserted-by":"publisher","DOI":"10.1203\/PDR.0b013e318193f117"}],"container-title":["Archives of Disease in Childhood - Fetal and Neonatal Edition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/archdischild-2018-315838","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T19:12:45Z","timestamp":1757099565000},"score":1,"resource":{"primary":{"URL":"https:\/\/fn.bmj.com\/lookup\/doi\/10.1136\/archdischild-2018-315838"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,19]]},"references-count":27,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2019,8,19]]},"published-print":{"date-parts":[[2019,9]]}},"alternative-id":["10.1136\/archdischild-2018-315838"],"URL":"https:\/\/doi.org\/10.1136\/archdischild-2018-315838","relation":{},"ISSN":["1359-2998","1468-2052"],"issn-type":[{"value":"1359-2998","type":"print"},{"value":"1468-2052","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12,19]]}}}