{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T21:22:58Z","timestamp":1790716978687,"version":"4.1.0"},"reference-count":22,"publisher":"BMJ","issue":"3","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Arch Dis Child Fetal Neonatal Ed"],"accepted":{"date-parts":[[2019,7,16]]},"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:sec>\n                  <jats:title>Objectives<\/jats:title>\n                  <jats:p>To compare situation awareness (SA), visual attention (VA) and protocol adherence in simulated neonatal resuscitations using two different monitor positions.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Design<\/jats:title>\n                  <jats:p>Randomised controlled simulation study.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Settings<\/jats:title>\n                  <jats:p>Simulation lab at the Royal Alexandra Hospital, Edmonton, Canada.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Participants<\/jats:title>\n                  <jats:p>Healthcare providers (HCPs) with Neonatal Resuscitation Program (NRP) certification within the last 2\u2009years and trained in neonatal endotracheal intubations.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Intervention<\/jats:title>\n                  <jats:p>HCPs were randomised to either central (eye-level on the radiant warmer) or peripheral (above eye-level, wall-mounted) monitor positions. Each led a complex resuscitation with a high-fidelity mannequin and a standardised assistant. To measure SA, situation awareness global assessment tool (SAGAT) was used, where simulations were paused at three predetermined points, with five questions asked each pause. Videos were analysed for SAGAT and adherence to a NRP checklist. Eye-tracking glasses recorded participants\u2019 VA.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Main outcome measure<\/jats:title>\n                  <jats:p>The main outcome was SA as measured by composite SAGAT score. Secondary outcomes included VA and adherence to NRP checklist.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Thirty simulations were performed; 29 were completed per protocol and analysed. Twenty-two eye-tracking recordings were of sufficient quality and analysed. Median composite SAGAT was 11.5\/15 central versus 11\/15 peripheral, p=0.56. Checklist scores 46\/50 central versus 46\/50 peripheral, p=0.75. Most VA was directed at the mannequin (30.6% central vs 34.1% peripheral, p=0.76), and the monitor (28.7% central vs 20.5% peripheral, p=0.06).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>Simulation, SAGAT and eye-tracking can be used to evaluate human factors of neonatal resuscitation. During simulated neonatal resuscitation, monitor position did not affect SA, VA or protocol adherence.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/archdischild-2019-316992","type":"journal-article","created":{"date-parts":[[2019,8,2]],"date-time":"2019-08-02T17:15:33Z","timestamp":1564766133000},"page":"285-291","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":11,"title":["Effect of monitor positioning on visual attention and situation awareness during neonatal resuscitation: a randomised simulation study"],"prefix":"10.1136","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4819-9253","authenticated-orcid":false,"given":"Brenda Hiu Yan","family":"Law","sequence":"first","affiliation":[{"name":"Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada"},{"name":"Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Po-Yin","family":"Cheung","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada"},{"name":"Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sylvia","family":"van Os","sequence":"additional","affiliation":[{"name":"Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caroline","family":"Fray","sequence":"additional","affiliation":[{"name":"Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9798-2415","authenticated-orcid":false,"given":"Georg M","family":"Schm\u00f6lzer","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada"},{"name":"Centre for the Studies of Asphyxia and Resuscitation, Royal Alexandra Hospital, Edmonton, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2019,8,2]]},"reference":[{"key":"2025090501565864000_105.3.285.1","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000000267"},{"key":"2025090501565864000_105.3.285.2","doi-asserted-by":"crossref","unstructured":"Weiner GM , Zaichkin J . Kattwinkel J editors. In: Textbook of Neonatal Resuscitation (NRP). 7th ed. Elk Grove Village, IL: American Academy of Pediatrics, 2016.","DOI":"10.1542\/9781610020251"},{"key":"2025090501565864000_105.3.285.3","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2017-313114"},{"key":"2025090501565864000_105.3.285.4","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1097\/SIH.0000000000000192","article-title":"Eye tracking: a novel approach for evaluating and improving the safety of healthcare processes in the simulated setting","volume":"12","author":"Henneman","year":"2017","journal-title":"Simul Healthc"},{"key":"2025090501565864000_105.3.285.5","doi-asserted-by":"crossref","unstructured":"Endsley MR . Theoretical underpinnings of situation awareness: a critical review, Situation Awareness Analysis and Measurement. Endsley MR , Garland DJ , eds. Mahwah, NJ: Lawrence Erlbaum Associates, 2000:3\u201328.","DOI":"10.1201\/b12461"},{"key":"2025090501565864000_105.3.285.6","doi-asserted-by":"publisher","DOI":"10.1518\/001872095779049543"},{"issue":"Suppl 1","key":"2025090501565864000_105.3.285.7","doi-asserted-by":"crossref","first-page":"i65","DOI":"10.1136\/qshc.2004.009951","article-title":"Objective measures of situation awareness in a simulated medical environment","volume":"13 Suppl 1","author":"Wright","year":"2004","journal-title":"Qual Saf Health Care"},{"key":"2025090501565864000_105.3.285.8","first-page":"1","article-title":"Measuring situation awareness in emergency settings: a systematic review of tools and outcomes","volume":"6","author":"Cooper","year":"2014","journal-title":"Open Access Emerg Med"},{"key":"2025090501565864000_105.3.285.9","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/SIH.0000000000000181","article-title":"Examining the feasibility and predictive validity of the sagat tool to assess situation awareness among medical trainees","volume":"12","author":"Gardner","year":"2017","journal-title":"Simul Healthc"},{"key":"2025090501565864000_105.3.285.10","doi-asserted-by":"publisher","DOI":"10.1097\/01.ta.0000238687.23622.89"},{"key":"2025090501565864000_105.3.285.11","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jsurg.2014.07.009","article-title":"Use of human patient simulation and validation of the Team Situation Awareness Global Assessment Technique (TSAGAT): a multidisciplinary team assessment tool in trauma education","volume":"72","author":"Crozier","year":"2015","journal-title":"J Surg Educ"},{"key":"2025090501565864000_105.3.285.12","doi-asserted-by":"crossref","first-page":"13","DOI":"10.3109\/13561820.2014.936371","article-title":"Using a situational awareness global assessment technique for interprofessional obstetrical team training with high fidelity simulation","volume":"29","author":"Morgan","year":"2015","journal-title":"J Interprof Care"},{"key":"2025090501565864000_105.3.285.13","unstructured":"Endsley MR . Designing for situation awareness: an approach to user-centered design. Boca Raton, FL: CRC Press 2012."},{"key":"2025090501565864000_105.3.285.14","doi-asserted-by":"publisher","DOI":"10.1177\/0956797613479386"},{"key":"2025090501565864000_105.3.285.15","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2006-0537"},{"key":"2025090501565864000_105.3.285.16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s41077-016-0033-y","article-title":"Validation of educational assessments: a primer for simulation and beyond","volume":"1","author":"Cook","year":"2016","journal-title":"Adv Simul"},{"key":"2025090501565864000_105.3.285.17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2014\/975752","article-title":"Combining first-person video and gaze-tracking in medical simulation: a technical feasibility study","volume":"2014","author":"Szulewski","year":"2014","journal-title":"Scientific World Journal"},{"key":"2025090501565864000_105.3.285.18","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1111\/anae.13821","article-title":"An investigation into the effects of real vs. stimulated cases and level of experience on the distribution of visual attention during induction of general anaesthesia","volume":"72","author":"Grundgeiger","year":"2017","journal-title":"Anaesthesia"},{"key":"2025090501565864000_105.3.285.19","doi-asserted-by":"crossref","unstructured":"Kottayil NK , Bogdanova R , Cheng I , et al . Investigation of gaze patterns in multi view laparoscopic surgery: 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). 2016:4031\u20134.","DOI":"10.1109\/EMBC.2016.7591611"},{"key":"2025090501565864000_105.3.285.20","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aer087"},{"key":"2025090501565864000_105.3.285.21","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2017-314119"},{"key":"2025090501565864000_105.3.285.22","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2017-314449"}],"container-title":["Archives of Disease in Childhood - Fetal and Neonatal Edition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/archdischild-2019-316992","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T09:01:46Z","timestamp":1757062906000},"score":1,"resource":{"primary":{"URL":"https:\/\/fn.bmj.com\/lookup\/doi\/10.1136\/archdischild-2019-316992"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,2]]},"references-count":22,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020,4,17]]},"published-print":{"date-parts":[[2020,5]]}},"alternative-id":["10.1136\/archdischild-2019-316992"],"URL":"https:\/\/doi.org\/10.1136\/archdischild-2019-316992","relation":{},"ISSN":["1359-2998","1468-2052"],"issn-type":[{"value":"1359-2998","type":"print"},{"value":"1468-2052","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,2]]}}}