{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T19:05:35Z","timestamp":1793387135511,"version":"4.5.0"},"reference-count":24,"publisher":"BMJ","issue":"11","funder":[{"name":"Brazilian Council","award":["304355\/2020-8"],"award-info":[{"award-number":["304355\/2020-8"]}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Arch Dis Child"],"published-print":{"date-parts":[[2023,11]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>We conducted a systematic review and meta\u2010analysis of diagnostic test accuracy studies to summarise the properties of sweat conductivity (SC) to rule in\/out cystic fibrosis (CF).<\/jats:p><\/jats:sec><jats:sec><jats:title>Data source<\/jats:title><jats:p>We searched PubMed, Embase, Web of Science, Google Scholar, SciELO and LILACS up to 13 March 2023.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study selection<\/jats:title><jats:p>We selected prospective and retrospective diagnostic test accuracy studies which compared SC, measured through two well-established and commercially available devices, that is, Nanoduct or Sweat-Chek Analyser, to quantitative measurement of sweat chloride.<\/jats:p><\/jats:sec><jats:sec><jats:title>Main outcome measures<\/jats:title><jats:p>Pooled sensitivity, specificity, positive likelihood ratio (+LR) and negative likelihood ratio (\u2212LR), and their corresponding 95% CIs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Data extraction and synthesis<\/jats:title><jats:p>The Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies guidelines were followed. Data were extracted by one reviewer and checked by another. The hierarchical summary receiver operating characteristics model was used to estimate diagnostic test accuracy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Ten studies involving 8286 participants were included. The pooled estimates of sensitivity, specificity, +LR and \u2212LR were 0.97 (95% CI 0.94 to 0.98), 0.99 (95% CI 0.98 to 0.99), 171 (95% CI 58 to 500) and 0.02 (95% CI 0.01 to 0.05), respectively. Sensitivity analyses did not reveal a substantial impact of study-level factors on the results, such as study quality, cut-off values for a positive test, study sample size and participant age group. The quality of evidence was considered moderate.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>SC demonstrated excellent diagnostic performance. In addition, its accuracy parameters suggest its role as an alternative to the sweat test for CF diagnosis.<\/jats:p><\/jats:sec><jats:sec><jats:title>PROSPERO registration number<\/jats:title><jats:p>CRD42022284504.<\/jats:p><\/jats:sec>","DOI":"10.1136\/archdischild-2023-325629","type":"journal-article","created":{"date-parts":[[2023,7,14]],"date-time":"2023-07-14T17:20:38Z","timestamp":1689355238000},"page":"904-909","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":8,"title":["Sweat conductivity diagnostic accuracy for cystic fibrosis: a systematic review and meta-analysis"],"prefix":"10.1136","volume":"108","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5150-5840","authenticated-orcid":false,"given":"Linjie","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seiko","family":"Nomiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renata Marcos","family":"Bedran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina Gon\u00e7alves","family":"Alvim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 Dirceu","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4731-291X","authenticated-orcid":false,"given":"Paulo","family":"Camargos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2023,7,14]]},"reference":[{"key":"2023103003200619000_108.11.904.1","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1093\/clinchem\/3.1.37","article-title":"Measurement of the electrical conductivity of sweat: its application to the study of cystic fibrosis of the pancreas","volume":"3","author":"Licht","year":"1957","journal-title":"Clin Chem"},{"key":"2023103003200619000_108.11.904.2","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1542\/peds.32.1.85","article-title":"R: electrical conductivity of sweat: a simple diagnostic test in children","volume":"32","author":"Shwachman","year":"1963","journal-title":"Pediatrics"},{"key":"2023103003200619000_108.11.904.3","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/S0022-3476(65)80199-8","article-title":"A standard procedure for measuring conductivity of sweat as a diagnostic test for cystic fibrosis","volume":"66","author":"Shwachman","year":"1965","journal-title":"J Pediatr"},{"key":"2023103003200619000_108.11.904.4","first-page":"158","article-title":"Pilocarpine Iontophoresis sweat testing results of seven years' experience","volume":"86","author":"Shwachman","year":"1967","journal-title":"Bibl Paediatr"},{"key":"2023103003200619000_108.11.904.5","doi-asserted-by":"publisher","DOI":"10.1080\/080352500750043378"},{"key":"2023103003200619000_108.11.904.6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S1569-1993(02)00146-7","article-title":"Sweat conductivity and chloride titration for cystic fibrosis diagnosis in 3834 subjects","volume":"2","author":"Lezana","year":"2003","journal-title":"J Cyst Fibros"},{"key":"2023103003200619000_108.11.904.7","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.jpeds.2004.08.085","article-title":"Conductivity determined by a new sweat analyzer compared with chloride concentrations for the diagnosis of cystic fibrosis","volume":"146","author":"Barben","year":"2005","journal-title":"J Pediatr"},{"key":"2023103003200619000_108.11.904.8","doi-asserted-by":"publisher","DOI":"10.1007\/s00431-007-0485-0"},{"key":"2023103003200619000_108.11.904.9","first-page":"109","article-title":"Comparison between classic Gibson and Cooke technique and sweat conductivity test in patients with and without cystic fibrosis","volume":"86","author":"Mattar","year":"2010","journal-title":"J Pediatr (Rio J)"},{"key":"2023103003200619000_108.11.904.10","first-page":"576","article-title":"Sweat conductivity test: can it replace chloride titration for cystic fibrosis diagnosis","volume":"54","author":"Cinel","year":"2012","journal-title":"Turk J Pediatr"},{"key":"2023103003200619000_108.11.904.11","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.jcf.2014.01.002","article-title":"Sweat conductivity: an accurate diagnostic test for cystic fibrosis?","volume":"13","author":"Mattar","year":"2014","journal-title":"J Cyst Fibros"},{"key":"2023103003200619000_108.11.904.12","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1016\/j.jped.2015.03.003","article-title":"Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening","volume":"91","author":"Domingos","year":"2015","journal-title":"J Pediatr (Rio J)"},{"key":"2023103003200619000_108.11.904.13","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1002\/ppul.24227","article-title":"Comparison of two sweat test systems for the diagnosis of cystic fibrosis in newborns","volume":"54","author":"Rueegg","year":"2019","journal-title":"Pediatr Pulmonol"},{"key":"2023103003200619000_108.11.904.14","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2022-324723"},{"key":"2023103003200619000_108.11.904.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpeds.2016.09.064"},{"key":"2023103003200619000_108.11.904.16","unstructured":"Association for Clinical Biochemistry & Laboratory Medicine . Guidelines for the performance of the sweat test for the investigation of cystic Fibrosis in the UK. 2nd Version. 2014. Available: www.acb.org.uk"},{"key":"2023103003200619000_108.11.904.17","first-page":"115","article-title":"Australasian guideline (2ND edition): an annex to the CLSI and UK guidelines for the performance of the sweat test for the diagnosis of cystic fibrosis","volume":"38","author":"Massie","year":"2017","journal-title":"Clin Biochem Rev"},{"key":"2023103003200619000_108.11.904.18","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.jcf.2018.02.006","article-title":"ECFS best practice guidelines: the 2018 revision","volume":"17","author":"Castellani","year":"2018","journal-title":"J Cyst Fibros"},{"key":"2023103003200619000_108.11.904.19","doi-asserted-by":"crossref","unstructured":"Salameh J-P , Bossuyt PM , McGrath TA , et al . Preferred reporting items for systematic review and meta-analysis of diagnostic test accuracy studies (PRISMA-DTA): explanation, elaboration, and checklist. BMJ 2020;370:m2632. doi:10.1136\/bmj.m2632","DOI":"10.1136\/bmj.m2632"},{"key":"2023103003200619000_108.11.904.20","doi-asserted-by":"publisher","DOI":"10.1059\/0003-4819-155-8-201110180-00009"},{"key":"2023103003200619000_108.11.904.21","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.jclinepi.2019.12.021","article-title":"GRADE guidelines: 21 part 2. test accuracy: inconsistency, imprecision, publication bias, and other domains for rating the certainty of evidence and presenting it in evidence profiles and summary of findings tables","volume":"122","author":"Sch\u00fcnemann","year":"2020","journal-title":"J Clin Epidemiol"},{"key":"2023103003200619000_108.11.904.22","doi-asserted-by":"crossref","first-page":"443","DOI":"10.2223\/JPED.91","article-title":"Comparison of conductivity with sodium determination in the same sweat sample","volume":"76","author":"Riedi","year":"2000","journal-title":"J Pediatr (Rio J)"},{"key":"2023103003200619000_108.11.904.23","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1007\/s00431-015-2501-0","article-title":"Clinical evaluation of the Nanoduct sweat test system in the diagnosis of cystic fibrosis after newborn screening","volume":"174","author":"Vernooij-van Langen","year":"2015","journal-title":"Eur J Pediatr"},{"key":"2023103003200619000_108.11.904.24","doi-asserted-by":"publisher","DOI":"10.1136\/adc.82.5.420"}],"container-title":["Archives of Disease in Childhood"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/archdischild-2023-325629","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T10:21:46Z","timestamp":1698661306000},"score":1,"resource":{"primary":{"URL":"https:\/\/adc.bmj.com\/lookup\/doi\/10.1136\/archdischild-2023-325629"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,14]]},"references-count":24,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2023,10,30]]},"published-print":{"date-parts":[[2023,11]]}},"alternative-id":["10.1136\/archdischild-2023-325629"],"URL":"https:\/\/doi.org\/10.1136\/archdischild-2023-325629","relation":{},"ISSN":["0003-9888","1468-2044"],"issn-type":[{"value":"0003-9888","type":"print"},{"value":"1468-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,14]]}}}