{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T01:07:13Z","timestamp":1781572033226,"version":"3.54.5"},"reference-count":23,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T00:00:00Z","timestamp":1747008000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"National Institute of Health","award":["K23HL157618"],"award-info":[{"award-number":["K23HL157618"]}]},{"name":"Owlet Baby Care Inc."}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Arch Dis Child Fetal Neonatal Ed"],"accepted":{"date-parts":[[2025,4,21]]},"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To determine the diagnostic accuracy of an over-the-counter infant pulse oximeter for cardiorespiratory events.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Single-centre prospective diagnostic accuracy study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting<\/jats:title>\n                    <jats:p>University of Alabama at Birmingham.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients<\/jats:title>\n                    <jats:p>Infants weighing \u22651500 g, &lt;44 weeks\u2019 postmenstrual age (PMA) and off ventilator\/continuous positive airway pressure support.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions<\/jats:title>\n                    <jats:p>Test device for 48 hours in addition to standard hospital monitors, ECG and pulse oximetry.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main outcome measures<\/jats:title>\n                    <jats:p>\n                      Data were time aligned and analysed using MATLAB. The coprimary outcomes were the diagnostic accuracy of the test device for the detection of events with heart rate (HR) &lt;50 beats per minute (bpm) and events with oxygen saturations (SpO\n                      <jats:sub>2<\/jats:sub>\n                      ) &lt;80% for \u22653\u2009s.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      66 infants with a median gestational age of 31 weeks (range 23\u201340) were studied at a median 35 weeks\u2019 PMA (range 32\u201342) weighing 1930\u2009g (range 1500\u20133605\u2009g) from April to July 2023. The sensitivity for detection of HR &lt;50\u2009bpm \u22653\u2009s was 6% and 39% for smoothed and raw data, respectively, while the specificity was &gt;99% for both smoothed and raw data. The sensitivity for SpO\n                      <jats:sub>2<\/jats:sub>\n                      &lt;80% \u22653\u2009s was 14% and 74%, while the specificity was &gt;99%\u2009and 96% for smoothed and raw data, respectively. Sensitivity for bradycardia events was higher for events with longer durations and\/or when using higher thresholds. Sensitivity was higher for hypoxaemia events with longer durations and\/or when using higher thresholds.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>An over-the-counter infant pulse oximeter had high specificity for bradycardia and hypoxaemia events consistent with a low false alarm rate. Sensitivity improved with longer events and higher event thresholds.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration number<\/jats:title>\n                    <jats:p>\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"clintrialgov\" xlink:href=\"NCT05774470\">NCT05774470<\/jats:ext-link>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/archdischild-2025-328540","type":"journal-article","created":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T13:20:18Z","timestamp":1747056018000},"page":"F13-F19","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":3,"title":["Diagnostic accuracy of an over-the-counter infant pulse oximeter for cardiorespiratory events"],"prefix":"10.1136","volume":"111","clinical-trial-number":[{"clinical-trial-number":"nct05774470","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct05774470","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3218-1024","authenticated-orcid":false,"given":"Colm P","family":"Travers","sequence":"first","affiliation":[{"name":"Department of Pediatrics, The University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arie","family":"Nakhmani","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimberly M","family":"Armstead","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, The University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel L","family":"Benz","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, The University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathryn M","family":"Foshee","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, The University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0382-9976","authenticated-orcid":false,"given":"Waldemar A","family":"Carlo","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, The University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,5,12]]},"reference":[{"key":"2025121502100837000_111.1.F13.1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2016.19137"},{"key":"2025121502100837000_111.1.F13.2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.93.1.44"},{"key":"2025121502100837000_111.1.F13.3","doi-asserted-by":"publisher","DOI":"10.1203\/00006450-199903000-00010"},{"key":"2025121502100837000_111.1.F13.4","doi-asserted-by":"crossref","DOI":"10.1542\/peds.2016-2938","article-title":"SIDS and Other Sleep-Related Infant Deaths: Updated 2016 Recommendations for a Safe Infant Sleeping Environment","volume":"138","year":"2016","journal-title":"Pediatrics"},{"key":"2025121502100837000_111.1.F13.5","doi-asserted-by":"crossref","DOI":"10.1542\/peds.2022-057990","article-title":"Sleep-Related Infant Deaths: Updated 2022 Recommendations for Reducing Infant Deaths in the Sleep Environment","volume":"150","author":"Moon","year":"2022","journal-title":"Pediatrics"},{"key":"2025121502100837000_111.1.F13.6","doi-asserted-by":"crossref","DOI":"10.1542\/peds.2022-057991","article-title":"Evidence Base for 2022 Updated Recommendations for a Safe Infant Sleeping Environment to Reduce the Risk of Sleep-Related Infant Deaths","volume":"150","author":"Moon","year":"2022","journal-title":"Pediatrics"},{"key":"2025121502100837000_111.1.F13.7","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2018.9018"},{"key":"2025121502100837000_111.1.F13.8","doi-asserted-by":"publisher","DOI":"10.1055\/s-0043-1768068"},{"key":"2025121502100837000_111.1.F13.9","unstructured":"Owlet Baby Care, Inc . Accuracy Evaluation of the FDA-Cleared BabySat\u2122 Pulse Oximeter in a Home-Monitoring Study. Available: https:\/\/indusmedtechsolutions.com\/assets\/documents\/Accuracy_measure_of_FDA-cleared_babysat.pdf [Accessed 21 Aug 2024]."},{"key":"2025121502100837000_111.1.F13.10","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1001\/jamainternmed.2022.1906","article-title":"Racial and Ethnic Discrepancy in Pulse Oximetry and Delayed Identification of Treatment Eligibility Among Patients With COVID-19 [Erratum in: JAMA Intern Med. 2022 Oct 1;182(10):1108. PMID: 35639368; PMCID: PMC9257583]","volume":"182","author":"Fawzy","year":"2022","journal-title":"JAMA Intern Med"},{"key":"2025121502100837000_111.1.F13.11","doi-asserted-by":"publisher","DOI":"10.1038\/s41372-021-01230-3"},{"key":"2025121502100837000_111.1.F13.12","doi-asserted-by":"crossref","DOI":"10.1097\/pq9.0000000000000538","article-title":"Parental Insights into Improving Home Pulse Oximetry Monitoring in Infants","volume":"7","author":"Ferro","year":"2022","journal-title":"Pediatr Qual Saf"},{"key":"2025121502100837000_111.1.F13.13","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2022.18367","article-title":"Alarm Burden in Infants With Bronchopulmonary Dysplasia Monitored With Pulse Oximetry at Home","volume":"5","author":"Herrick","year":"2022","journal-title":"JAMA Netw Open"},{"key":"2025121502100837000_111.1.F13.14","doi-asserted-by":"publisher","DOI":"10.1136\/adc.60.11.1055"},{"key":"2025121502100837000_111.1.F13.15","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.2011.02464.x"},{"key":"2025121502100837000_111.1.F13.16","doi-asserted-by":"publisher","DOI":"10.1001\/jama.285.17.2199"},{"key":"2025121502100837000_111.1.F13.17","doi-asserted-by":"publisher","DOI":"10.1001\/jama.285.17.2244"},{"key":"2025121502100837000_111.1.F13.18","doi-asserted-by":"crossref","DOI":"10.1177\/11786329231169604","article-title":"Healthcare Utilization Among Infants Discharged From the Neonatal Intensive Care Unit: A Descriptive Cost Analysis","volume":"16","author":"Hebballi","year":"2023","journal-title":"Health Serv Insights"},{"key":"2025121502100837000_111.1.F13.19","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2023.30856","article-title":"Clinical Outcomes Associated With Overestimation of Oxygen Saturation by Pulse Oximetry in Patients Hospitalized With COVID-19","volume":"6","author":"Fawzy","year":"2023","journal-title":"JAMA Netw Open"},{"key":"2025121502100837000_111.1.F13.20","doi-asserted-by":"publisher","DOI":"10.1016\/S2589-7500(21)00276-4"},{"key":"2025121502100837000_111.1.F13.21","doi-asserted-by":"crossref","DOI":"10.1177\/2333794X17742751","article-title":"Initial Experience and Usage Patterns With the Owlet Smart Sock Monitor in 47,495 Newborns","volume":"4","author":"Dangerfield","year":"2017","journal-title":"Glob Pediatr Health"},{"key":"2025121502100837000_111.1.F13.22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpeds.2020.12.080"},{"key":"2025121502100837000_111.1.F13.23","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.g6639","article-title":"Marketing wearable home baby monitors: real peace of mind?","volume":"349","author":"King","year":"2014","journal-title":"BMJ"}],"container-title":["Archives of Disease in Childhood - Fetal and Neonatal Edition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/archdischild-2025-328540","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,15]],"date-time":"2025-12-15T10:11:08Z","timestamp":1765793468000},"score":1,"resource":{"primary":{"URL":"https:\/\/fn.bmj.com\/lookup\/doi\/10.1136\/archdischild-2025-328540"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,12]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12,15]]},"published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1136\/archdischild-2025-328540"],"URL":"https:\/\/doi.org\/10.1136\/archdischild-2025-328540","relation":{},"ISSN":["1359-2998","1468-2052"],"issn-type":[{"value":"1359-2998","type":"print"},{"value":"1468-2052","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,12]]}}}