{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:27:37Z","timestamp":1792787257966,"version":"4.5.0"},"reference-count":32,"publisher":"BMJ","license":[{"start":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:00:00Z","timestamp":1790640000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100018956","name":"NIHR Cambridge Biomedical Research Centre","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100018956","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Cambridge Clinical Trials Unit","id":[{"id":"https:\/\/ror.org\/00s06sw72","id-type":"ROR","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100001922","name":"Efficacy and Mechanism Evaluation Programme","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001922","id-type":"DOI","asserted-by":"publisher"}]},{"name":"NIHR Clinical Research Network Eastern","id":[{"id":"https:\/\/ror.org\/05fj7ar22","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Arch Dis Child Fetal Neonatal Ed"],"accepted":{"date-parts":[[2026,8,27]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To explore the clinical performance of continuous glucose monitoring (CGM) in very preterm infants during the first week of life, using data from the multicentre Real time continuous glucose monitoring (REACT) randomised controlled trial (RCT) and to consider how CGM can best support neonatal glucose management.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Prespecified secondary analysis of paired sensor glucose (SG) and blood glucose (BG) measurements from the REACT RCT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting<\/jats:title>\n                    <jats:p>13 neonatal intensive care units (NICUs) in the UK, Spain and the Netherlands.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients<\/jats:title>\n                    <jats:p>155 very preterm infants (\u22641200\u2009g birth weight or &lt;34\u2009weeks\u2019 gestation) with CGM data collected during the first week of life.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main outcome measures<\/jats:title>\n                    <jats:p>Mean absolute relative difference (MARD), ISO 15197:2013 system agreement, Bland-Altman bias, error grid analysis and clinical contextualisation of CGM performance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Across 2223 SG-BG pairs, overall MARD was 11.9%, and 98%\u201399%\u2009of values fell within clinically acceptable error grid zones. SG tended to be less accurate at BG extremes, although error grid analyses show that clinical risk from discrepancies was low. CGM detected episodes of dysglycaemia not captured by intermittent sampling. Glucose variability did not materially influence accuracy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>CGM can provide clinically meaningful information in very preterm infants despite modest analytical inaccuracy when compared with single point-of-care values. Its greatest utility lies in continuous trend monitoring, early detection of silent dysglycaemia and reduced invasive sampling, rather than replacement of diagnostic blood testing. Clinicians should interpret SG values in context, confirm unexpected extremes with BG and focus on patterns rather than single values.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/archdischild-2026-330804","type":"journal-article","created":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T17:20:24Z","timestamp":1790702424000},"page":"fetalneonatal-2026-330804","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical performance and practical implications of continuous glucose monitoring in very preterm infants: a cohort study"],"prefix":"10.1136","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4261-9683","authenticated-orcid":false,"given":"Gordon Xin Hua","family":"Liu","sequence":"first","affiliation":[{"name":"School of Medicine, University of Auckland, Grafton Campus, Auckland, New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4415-316X","authenticated-orcid":false,"given":"Loredana","family":"Marcovecchio","sequence":"additional","affiliation":[{"name":"Department of Paediatrics, University of Cambridge, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3582-183X","authenticated-orcid":false,"given":"Kathryn","family":"Beardsall","sequence":"additional","affiliation":[{"name":"Department of Paediatrics, University of Cambridge, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,9,29]]},"reference":[{"key":"2026092910201548000_archdischild-2026-330804v1.1","doi-asserted-by":"publisher","DOI":"10.1542\/neo.21-1-e14"},{"key":"2026092910201548000_archdischild-2026-330804v1.2","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2008.154716"},{"key":"2026092910201548000_archdischild-2026-330804v1.3","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2025-328701"},{"key":"2026092910201548000_archdischild-2026-330804v1.4","doi-asserted-by":"crossref","first-page":"335","DOI":"10.21037\/tp.2017.10.06","article-title":"Hypoglycemia in the preterm neonate: etiopathogenesis, diagnosis, management and long-term outcomes","volume":"6","author":"Sharma","year":"2017","journal-title":"Transl Pediatr"},{"key":"2026092910201548000_archdischild-2026-330804v1.5","doi-asserted-by":"publisher","DOI":"10.1542\/neo.21-2-e89"},{"key":"2026092910201548000_archdischild-2026-330804v1.6","doi-asserted-by":"crossref","first-page":"1115228","DOI":"10.3389\/fped.2023.1115228","article-title":"Should continuous glucose monitoring be used to manage neonates at risk of hypoglycaemia?","volume":"11","author":"Kalogeropoulou","year":"2023","journal-title":"Front Pediatr"},{"key":"2026092910201548000_archdischild-2026-330804v1.7","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/S2352-4642(20)30367-9","article-title":"Real-time continuous glucose monitoring in preterm infants (REACT): an international, open-label, randomised controlled trial","volume":"5","author":"Beardsall","year":"2021","journal-title":"Lancet Child Adolesc Health"},{"key":"2026092910201548000_archdischild-2026-330804v1.8","doi-asserted-by":"crossref","first-page":"30","DOI":"10.3389\/fped.2020.00030","article-title":"Early Neonatal Pain-A Review of Clinical and Experimental Implications on Painful Conditions Later in Life","volume":"8","author":"Williams","year":"2020","journal-title":"Front Pediatr"},{"key":"2026092910201548000_archdischild-2026-330804v1.9","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0076702","article-title":"Neonatal pain-related stress predicts cortical thickness at age 7 years in children born very preterm","volume":"8","author":"Ranger","year":"2013","journal-title":"PLoS One"},{"key":"2026092910201548000_archdischild-2026-330804v1.10","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1038\/s41390-024-03411-0","article-title":"Neonatal dysglycemia: a review of dysglycemia in relation to brain health and neurodevelopmental outcomes","volume":"96","author":"Lagac\u00e9","year":"2024","journal-title":"Pediatr Res"},{"key":"2026092910201548000_archdischild-2026-330804v1.11","doi-asserted-by":"crossref","DOI":"10.1007\/s00431-025-06082-z","article-title":"Exploring the long-term impacts of neonatal hypoglycemia to determine a safe threshold for glucose concentrations","volume":"184","author":"Garg","year":"2025","journal-title":"Eur J Pediatr"},{"key":"2026092910201548000_archdischild-2026-330804v1.12","doi-asserted-by":"crossref","first-page":"161","DOI":"10.3803\/EnM.2025.2370","article-title":"Advances in Continuous Glucose Monitoring: Clinical Applications","volume":"40","author":"Kwon","year":"2025","journal-title":"Endocrinol Metab (Seoul)"},{"key":"2026092910201548000_archdischild-2026-330804v1.13","unstructured":"National Institute for Health and Care Excellence . QS208. Type 1 diabetes in adults. 2023."},{"key":"2026092910201548000_archdischild-2026-330804v1.14","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2020-045335","article-title":"Accuracy of continuous glucose monitoring in preterm infants: a systematic review and meta-analysis","volume":"10","author":"Nava","year":"2020","journal-title":"BMJ Open"},{"key":"2026092910201548000_archdischild-2026-330804v1.15","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.jnn.2024.09.001","article-title":"Continuous glucose monitoring in well term and near-term babies for monitoring hypoglycaemia","volume":"31","author":"Blackbourn","year":"2025","journal-title":"J Neonatal Nurs"},{"key":"2026092910201548000_archdischild-2026-330804v1.16","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2017-020816","article-title":"Protocol of a randomised controlled trial of real-time continuous glucose monitoring in neonatal intensive care \u201cREACT\u201d","volume":"8","author":"Beardsall","year":"2018","journal-title":"BMJ Open"},{"key":"2026092910201548000_archdischild-2026-330804v1.17","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1111\/jan.16908","article-title":"A Primer of Data Cleaning in Quantitative Research: Handling Missing Values and Outliers","volume":"82","author":"Sharifnia","year":"2026","journal-title":"J Adv Nurs"},{"key":"2026092910201548000_archdischild-2026-330804v1.18","unstructured":"International Organization for Standardization . ISO 15197:2013. in vitro diagnostic test systems \u2014 requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus. 2013."},{"key":"2026092910201548000_archdischild-2026-330804v1.19","unstructured":"Caldwell A . Agreement & tolerance limits. 2025. Available: https:\/\/cran.r-project.org\/web\/packages\/SimplyAgree\/vignettes\/agreement_analysis.html"},{"key":"2026092910201548000_archdischild-2026-330804v1.20","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.10.5.622"},{"key":"2026092910201548000_archdischild-2026-330804v1.21","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.23.8.1143"},{"key":"2026092910201548000_archdischild-2026-330804v1.22","doi-asserted-by":"publisher","DOI":"10.1177\/1932296819855670"},{"key":"2026092910201548000_archdischild-2026-330804v1.23","doi-asserted-by":"publisher","DOI":"10.1177\/193229681300700405"},{"key":"2026092910201548000_archdischild-2026-330804v1.24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpeds.2024.114416"},{"key":"2026092910201548000_archdischild-2026-330804v1.25","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1111\/ped.13961","article-title":"Reliability of real-time continuous glucose monitoring in infants","volume":"61","author":"Tomotaki","year":"2019","journal-title":"Pediatr Int"},{"key":"2026092910201548000_archdischild-2026-330804v1.26","doi-asserted-by":"crossref","DOI":"10.1186\/s13052-018-0542-5","article-title":"Continuous glucose monitoring (CGM) in very low birth weight newborns needing parenteral nutrition: validation and glycemic percentiles","volume":"44","author":"Perri","year":"2018","journal-title":"Ital J Pediatr"},{"key":"2026092910201548000_archdischild-2026-330804v1.27","doi-asserted-by":"crossref","DOI":"10.1186\/s13052-016-0236-9","article-title":"Continuous glucose monitoring in preterm infants: evaluation by a modified Clarke error grid","volume":"42","author":"Tiberi","year":"2016","journal-title":"Ital J Pediatr"},{"key":"2026092910201548000_archdischild-2026-330804v1.28","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2018-314814"},{"key":"2026092910201548000_archdischild-2026-330804v1.29","doi-asserted-by":"crossref","DOI":"10.1007\/s00431-025-06284-5","article-title":"Glucose disturbances in very low birth weight infants nearing term age-results from the prospective LIGHT-study using continuous glucose monitoring","volume":"184","author":"Nilsson Zamir","year":"2025","journal-title":"Eur J Pediatr"},{"key":"2026092910201548000_archdischild-2026-330804v1.30","doi-asserted-by":"publisher","DOI":"10.1136\/archdischild-2012-301661"},{"key":"2026092910201548000_archdischild-2026-330804v1.31","doi-asserted-by":"crossref","first-page":"17","DOI":"10.3390\/diabetology6030017","article-title":"The History, Evolution and Future of Continuous Glucose Monitoring (CGM)","volume":"6","author":"Bender","year":"2025","journal-title":"Diabetology"},{"key":"2026092910201548000_archdischild-2026-330804v1.32","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/ANC.0000000000001055","article-title":"Physiological Effects of Handling in Moderate to Late Preterm Infants Receiving Neonatal Intensive Care","volume":"23","author":"Brashear","year":"2023","journal-title":"Adv Neonatal Care"}],"container-title":["Archives of Disease in Childhood - Fetal and Neonatal Edition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/archdischild-2026-330804","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T17:20:28Z","timestamp":1790702428000},"score":1,"resource":{"primary":{"URL":"https:\/\/fn.bmj.com\/lookup\/doi\/10.1136\/archdischild-2026-330804"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,29]]},"references-count":32,"alternative-id":["10.1136\/archdischild-2026-330804"],"URL":"https:\/\/doi.org\/10.1136\/archdischild-2026-330804","relation":{},"ISSN":["1359-2998","1468-2052"],"issn-type":[{"value":"1359-2998","type":"print"},{"value":"1468-2052","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,29]]}}}