{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:00:21Z","timestamp":1762506021509,"version":"3.44.0"},"reference-count":10,"publisher":"BMJ","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMJ Case Reports"],"abstract":"<jats:p>As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take chemotherapy because the device occluded. Further examination revealed the transection of the catheter. The transected fragment of the catheter in the heart was successfully removed by using a loop snare placed through the right femoral vein.<\/jats:p>","DOI":"10.1136\/bcr-2012-006584","type":"journal-article","created":{"date-parts":[[2012,11,30]],"date-time":"2012-11-30T11:14:12Z","timestamp":1354274052000},"page":"bcr2012006584","source":"Crossref","is-referenced-by-count":5,"title":["Pinch-off syndrome: transection of implantable central venous access device"],"prefix":"10.1136","volume":"2012","author":[{"given":"Takuya","family":"Sugimoto","sequence":"first","affiliation":[{"name":"Department of Surgery, Kameda Medical Center, Kamogawa-city, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Nagata","sequence":"additional","affiliation":[{"name":"Department of Surgery, Kameda Medical Center, Kamogawa-city, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ken","family":"Hayashi","sequence":"additional","affiliation":[{"name":"Department of Surgery, Kameda Medical Center, Kamogawa-city, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuyasu","family":"Kano","sequence":"additional","affiliation":[{"name":"Department of Surgery, Kameda Medical Center, Kamogawa-city, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2012,11,30]]},"reference":[{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.1","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1177\/000313480407000715","article-title":"Pinch-off syndrome: case report and collective review of the literature","volume":"70","author":"Mirza","year":"2004","journal-title":"Am Surg"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.2","doi-asserted-by":"publisher","DOI":"10.1177\/0148607109335121"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.3","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1148\/radiology.177.2.2217768","article-title":"Pinch-off syndrome: a complication of implantable subclavian venous access devices","volume":"177","author":"Hinke","year":"1990","journal-title":"Radiology"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.4","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01607.x"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.5","doi-asserted-by":"publisher","DOI":"10.1245\/ASO.2005.04.028"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.6","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-010-9841-y"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.7","doi-asserted-by":"publisher","DOI":"10.1016\/S0959-8049(96)00274-2"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.8","doi-asserted-by":"publisher","DOI":"10.1016\/S0959-8049(97)89012-0"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.9","doi-asserted-by":"crossref","first-page":"527","DOI":"10.2214\/ajr.180.2.1800527","article-title":"Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients","volume":"180","author":"Bessoud","year":"2003","journal-title":"AJR Am J Roentgenol"},{"key":"2025082700020314000_2012.nov29_1.bcr2012006584.10","doi-asserted-by":"crossref","first-page":"541","DOI":"10.2214\/ajr.130.3.541","article-title":"Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies","volume":"130","author":"Fisher","year":"1978","journal-title":"AJR Am J Roentgenol"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2012-006584","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T07:02:12Z","timestamp":1756278132000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2012-006584"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11,30]]},"references-count":10,"alternative-id":["10.1136\/bcr-2012-006584"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2012-006584","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2012,11,30]]}}}