{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T18:10:12Z","timestamp":1773425412415,"version":"3.50.1"},"reference-count":10,"publisher":"BMJ","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Reports"],"accepted":{"date-parts":[[2015,10,12]]},"abstract":"<jats:p>A 64-year-old man was referred to our hospital for treatment of a cerebral aneurysm that was incidentally found. The aneurysm was 7\u2005mm in size and located on the left anterior communicating artery. Using a balloon assisted technique, we performed coil embolization. During the second coil insertion, the first coil was dislodged into the anterior communicating artery. We attempted coil retrieval using a snare, which was unsuccessful. We applied a direct aspiration first pass technique (ADAPT) and advanced a Penumbra 4MAX immediately proximal to the dislodged coil; the dislodged coil was then successfully retrieved. ADAPT is a simple procedure for retrieval of a detached coil, and it can be used as an alternative to the snare technique.<\/jats:p>","DOI":"10.1136\/bcr-2015-012039","type":"journal-article","created":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T20:22:48Z","timestamp":1715977368000},"page":"bcr2015012039","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["A direct aspiration first pass technique for retrieval of a detached coil"],"prefix":"10.1136","volume":"2015","author":[{"given":"Noritaka","family":"Masahira","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Kochi Health Sciences Center, Kochi City, Kochi Prefecture, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsuyoshi","family":"Ohta","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Kochi Health Sciences Center, Kochi City, Kochi Prefecture, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Fukui","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Kochi Medical School, Nankoku City, Kochi Prefecture, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshio","family":"Yanagawa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Kochi Medical School, Nankoku City, Kochi Prefecture, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuichirou","family":"Kondou","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Kochi Medical School, Nankoku City, Kochi Prefecture, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masanori","family":"Morimoto","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Kochi Health Sciences Center, Kochi City, Kochi Prefecture, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuya","family":"Ueba","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Kochi Medical School, Nankoku City, Kochi Prefecture, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2015,11,6]]},"reference":[{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.1","doi-asserted-by":"publisher","DOI":"10.1007\/s002340050757"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.2","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000103221.16671.F0"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.3","doi-asserted-by":"publisher","DOI":"10.3171\/jns.2002.96.2.0373"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.4","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-200004000-00051"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.5","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-006-0051-x"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.6","first-page":"809","article-title":"Microcatheter retrieval device for intravascular foreign body removal","volume":"14","author":"Smith","year":"1993","journal-title":"AJNR Am J Neuroradiol"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.7","doi-asserted-by":"publisher","DOI":"10.1227\/00006123-199411000-00038"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.8","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2013-010713"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.9","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1177\/159101990901500116","article-title":"Retrieval of a migrated coil using an X6 MERCI device","volume":"15","author":"O'Hare","year":"2009","journal-title":"I Interv Neuroradiol"},{"key":"2025082700263676000_2015.nov05_2.bcr2015012039.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocn.2012.06.012"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2015-012039","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T07:26:45Z","timestamp":1756279605000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2015-012039"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,6]]},"references-count":10,"alternative-id":["10.1136\/bcr-2015-012039"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2015-012039","relation":{},"ISSN":["1757-790X"],"issn-type":[{"value":"1757-790X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,6]]}}}