{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,28]],"date-time":"2025-04-28T04:01:17Z","timestamp":1745812877095,"version":"3.40.4"},"reference-count":13,"publisher":"BMJ","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Reports"],"accepted":{"date-parts":[[2018,1,8]]},"abstract":"<jats:p>Peripherally inserted central catheter (PICC) migration into azygos vein (AV) is a rare complication. It is recognised only when catheter malfunction occurs or when patients develop associated complications. PICC migration into AV has been reported to be associated with various complications such as catheter malfunction, perforation, haemorrhage, thrombosis, infection and stenosis of AV. Pleural effusion and trachea\u2013azygos fistulas have also been reported. We present a patient with recurrent migration of PICC into AV after an initial corrective repositioning during the same hospital stay. In this case, PICC migration was possibly related to left-sided approach, use of smaller diameter PICC, severe congestive heart failure and her bedbound status. PICC migration should be considered when PICC found be malfunctioning, especially if associated with the above risk factors.<\/jats:p>","DOI":"10.1136\/bcr-2017-221184","type":"journal-article","created":{"date-parts":[[2018,1,24]],"date-time":"2018-01-24T04:30:16Z","timestamp":1516768216000},"page":"bcr-2017-221184","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":4,"title":["Recurrent migration of peripherally inserted central catheter into the azygos vein"],"prefix":"10.1136","volume":"2018","author":[{"given":"Goutham","family":"Talari","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Preetham","family":"Talari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saurabh","family":"Parasramka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aibek E","family":"Mirrakhimov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2018,1,23]]},"reference":[{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.1","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1002\/jhm.2525","article-title":"The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) initiative: a summary and review of peripherally inserted central catheter and venous catheter appropriate use","volume":"11","author":"Woller","year":"2016","journal-title":"J Hosp Med"},{"issue":"Suppl 1","key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.2","doi-asserted-by":"crossref","first-page":"P128","DOI":"10.1186\/cc13318","article-title":"Development of a standardized method of peripherally inserted central catheter (PICC-line) bedside installation","volume":"18","author":"Hobeika","year":"2014","journal-title":"Critical Care"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.3","doi-asserted-by":"crossref","first-page":"e79","DOI":"10.5301\/jva.5000551","article-title":"Nerve damage secondary to removal of fractured PICC fragment","volume":"17","author":"Mou","year":"2016","journal-title":"J Vasc Access"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.4","doi-asserted-by":"publisher","DOI":"10.1002\/jmrs.98"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.5","doi-asserted-by":"crossref","first-page":"e143","DOI":"10.5301\/jva.5000554","article-title":"Central venous access through a persistent left superior vena cava: a case series","volume":"17","author":"Zhou","year":"2016","journal-title":"J Vasc Access"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.6","doi-asserted-by":"crossref","first-page":"e148","DOI":"10.5301\/jva.5000577","article-title":"Diagnosis of azygos catheter misplacement","volume":"17","author":"Marcy","year":"2016","journal-title":"J Vasc Access"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.7","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aes497"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.8","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5049.111884"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2011.05.011"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.10","doi-asserted-by":"crossref","first-page":"537","DOI":"10.5301\/jva.5000432","article-title":"Spontaneous migration of a peripherally inserted central catheter into the azygos vein in esophageal cancer patients during surgery","volume":"16","author":"Zhang","year":"2015","journal-title":"J Vasc Access"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.11","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2016-216657"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.12","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2006.05.6440"},{"key":"2025042702361476000_2018.jan23_1.bcr-2017-221184.13","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/00005382-199701000-00010","article-title":"Azygos arch cannulation by central venous catheters: radiographic detection of malposition and subsequent complications","volume":"12","author":"Bankier","year":"1997","journal-title":"J Thorac Imaging"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2017-221184","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,27]],"date-time":"2025-04-27T09:36:25Z","timestamp":1745746585000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2017-221184"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,23]]},"references-count":13,"alternative-id":["10.1136\/bcr-2017-221184"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2017-221184","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2018,1,23]]}}}