{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T08:10:03Z","timestamp":1756368603647,"version":"3.44.0"},"reference-count":30,"publisher":"BMJ","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Reports"],"accepted":{"date-parts":[[2018,5,18]]},"abstract":"<jats:p>Instability or recurrent dislocations are a common reason for revision of total hip replacements (THRs). Dual-mobility constructs can help improve stability by increasing the femoral head jump distance. These constructs are used to decrease the risk of re-revision in the setting of recurrent dislocation. This case describes an unusual case of irreducible dislocation of a re-revision THR due to intraprosthetic dislocation. The patient required open reduction and revision of this construct to a tripolar implant. This is important to appreciate from an emergency medicine point of view as repeated attempts at reduction will be fruitless and may result in a femur fracture. This particular type of dislocation is very rare. Perioperative considerations should include early referral to the orthopaedic team for reduction in theatre, and having a low threshold for open reduction. Revision options should be available when bringing a case like this to the operating theatre.<\/jats:p>","DOI":"10.1136\/bcr-2017-223072","type":"journal-article","created":{"date-parts":[[2018,6,4]],"date-time":"2018-06-04T03:30:35Z","timestamp":1528083035000},"page":"bcr-2017-223072","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Cause of irreducible dislocation of a re-revision THR"],"prefix":"10.1136","volume":"2018","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9847-3441","authenticated-orcid":false,"given":"Evelyn Patricia","family":"Murphy","sequence":"first","affiliation":[{"name":"Department of Trauma and Orthopaedics, Limerick University Hospital, Limerick, Ireland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Fenelon","sequence":"additional","affiliation":[{"name":"Limerick Univeristy Hospital, Limerick, Ireland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shane","family":"Russell","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedics, Limerick University Hospital, Limerick, Ireland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Finbarr","family":"Condon","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedics, Limerick University Hospital, Limerick, Ireland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2018,6,4]]},"reference":[{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.1","doi-asserted-by":"publisher","DOI":"10.5312\/wjo.v5.i3.180"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.2","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1007\/s00264-016-3363-4","article-title":"Dual mobility cups in revision total hip arthroplasty","volume":"41","author":"Viste","year":"2017","journal-title":"Int Orthop"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.3","doi-asserted-by":"publisher","DOI":"10.1007\/s002640050246"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.4","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2012.742395"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.07.008"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.6","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-197509000-00016"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.7","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1097\/00003086-198206000-00045","article-title":"Prosthetic hip range of motion and impingement. The effects of head and neck geometry","volume":"166","author":"Chandler","year":"1982","journal-title":"Clin Orthop Relat Res"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.8","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000150117.42360.f9"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2009.10.015"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.10","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-011-1289-4"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ocl.2013.08.004"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.12","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-014-3469-1"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.13","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2005.05.005"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.14","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1302\/0301-620X.72B3.2341446","article-title":"Primary total hip replacement in patients over 80 years of age","volume":"72","author":"Newington","year":"1990","journal-title":"J Bone Joint Surg Br"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.15","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-011-2146-x"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2006.12.111"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.17","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.02.016"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.18","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200212000-00006"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.19","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1007\/s11420-012-9287-7","article-title":"Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear","volume":"8","author":"Cross","year":"2012","journal-title":"Hss J"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.20","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1016\/j.jor.2017.08.010","article-title":"Polyethylene and highly cross-linked polyethylene for cemented total hip arthroplasty: A comparison of over ten-year clinical and radiographic results","volume":"14","author":"Kawata","year":"2017","journal-title":"J Orthop"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.21","doi-asserted-by":"publisher","DOI":"10.1016\/S0035-1040(05)84466-6"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.22","doi-asserted-by":"crossref","first-page":"585","DOI":"10.2106\/00004623-199504000-00012","article-title":"Revision of total hip arthroplasty in octogenarians","volume":"77","author":"Ballard","year":"1995","journal-title":"J Bone Joint Surg Am"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.23","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","article-title":"Dislocations after total hip-replacement arthroplasties","volume":"60","author":"Lewinnek","year":"1978","journal-title":"J Bone Joint Surg Am"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.24","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1007\/s00264-015-3000-7","article-title":"Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective","volume":"40","author":"Fabry","year":"2016","journal-title":"Int Orthop"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.25","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-008-0476-0"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.26","doi-asserted-by":"crossref","first-page":"e1124","DOI":"10.3928\/01477447-20141124-90","article-title":"Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA","volume":"37","author":"Odland","year":"2014","journal-title":"Orthopedics"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.27","first-page":"1013","article-title":"Intraprosthetic dislocation: a potentially serious complication of dual mobility acetabular cups","volume":"43","author":"Langlois","year":"2014","journal-title":"Skeletal Radiol"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.28","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1007\/s11999-015-4381-z","article-title":"Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component","volume":"474","author":"Fehring","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.29","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.00155"},{"key":"2025082800290568000_2018.jun01_1.bcr-2017-223072.30","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2003.011809"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2017-223072","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T07:29:14Z","timestamp":1756366154000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2017-223072"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,4]]},"references-count":30,"alternative-id":["10.1136\/bcr-2017-223072"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2017-223072","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2018,6,4]]}}}