{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T16:15:02Z","timestamp":1764260102286,"version":"3.44.0"},"reference-count":10,"publisher":"BMJ","issue":"10","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2019,9,27]]},"published-print":{"date-parts":[[2019,10]]},"abstract":"<jats:p>Flexible bronchoscopy is a commonly performed procedure in pulmonary medicine. The common complications following bronchoscopy include minor bleeding, transient hypoxaemia, pneumothorax and others. Pneumothorax during diagnostic flexible bronchoscopy is mainly encountered after performing transbronchial lung biopsy. Iatrogenic pneumothorax is uncommon when lung biopsy is not performed. Herein, we report the unusual occurrence of pneumothorax following bronchoscopic suctioning while removing a mucus plug.<\/jats:p>","DOI":"10.1136\/bcr-2019-230943","type":"journal-article","created":{"date-parts":[[2019,10,5]],"date-time":"2019-10-05T14:55:21Z","timestamp":1570287321000},"page":"e230943","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":4,"title":["Iatrogenic pneumothorax following vigorous suctioning of mucus plug during flexible bronchoscopy"],"prefix":"10.1136","volume":"12","author":[{"given":"Valliappan","family":"Muthu","sequence":"first","affiliation":[{"name":"Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Inderpaul Singh","family":"Sehgal","sequence":"additional","affiliation":[{"name":"Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7690-6595","authenticated-orcid":false,"given":"Kuruswamy Thurai","family":"Prasad","sequence":"additional","affiliation":[{"name":"Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ritesh","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2019,10,5]]},"reference":[{"key":"2025082710123298000_12.10.e230943.1","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2013-203618"},{"key":"2025082710123298000_12.10.e230943.2","doi-asserted-by":"crossref","unstructured":"Leiten EO , Martinsen EMH , Bakke PS , et al . Complications and discomfort of bronchoscopy: a systematic review. Eur Clin Respir J 2016;3.doi:10.3402\/ecrj.v3.33324","DOI":"10.3402\/ecrj.v3.33324"},{"issue":"Suppl 4","key":"2025082710123298000_12.10.e230943.3","first-page":"S427","article-title":"Pneumothorax after transbronchial needle biopsy","volume":"6","author":"Boskovic","year":"2014","journal-title":"J Thorac Dis"},{"key":"2025082710123298000_12.10.e230943.4","doi-asserted-by":"crossref","first-page":"e45","DOI":"10.1097\/LBR.0000000000000489","article-title":"Pneumothorax after a bronchoalveolar lavage","volume":"25","author":"Baldi","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"2025082710123298000_12.10.e230943.5","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1378\/chest.15-0022","article-title":"A randomized trial of 1% vs 2% lignocaine by the spray-as-you-go technique for topical anesthesia during flexible bronchoscopy","volume":"148","author":"Kaur","year":"2015","journal-title":"Chest"},{"key":"2025082710123298000_12.10.e230943.6","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-991520"},{"key":"2025082710123298000_12.10.e230943.7","doi-asserted-by":"publisher","DOI":"10.1183\/09059180.00006412"},{"issue":"Suppl 1","key":"2025082710123298000_12.10.e230943.8","first-page":"S124","article-title":"Pneumothorax following flexible fiberoptic bronchoscopy: a rare occurrence","volume":"8","author":"Soni","year":"2014","journal-title":"Saudi J Anaesth"},{"key":"2025082710123298000_12.10.e230943.9","doi-asserted-by":"publisher","DOI":"10.1097\/00007611-199309000-00019"},{"key":"2025082710123298000_12.10.e230943.10","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.1984.00350130175029"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2019-230943","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T17:12:40Z","timestamp":1756314760000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2019-230943"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":10,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2019,10,5]]},"published-print":{"date-parts":[[2019,10]]}},"alternative-id":["10.1136\/bcr-2019-230943"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2019-230943","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2019,10]]}}}