{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T21:40:57Z","timestamp":1757454057443,"version":"3.44.0"},"reference-count":20,"publisher":"BMJ","issue":"4","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2021,3,25]]},"published-print":{"date-parts":[[2021,4]]},"abstract":"<jats:p>We report a case of vertebral fracture with diffuse idiopathic skeletal hyperostosis (DISH) who underwent posterior dynamic stabilisation using mobile percutaneous pedicle screws (PPS) with 1 above-1 below and obtained good bone fusion. A 76-year-old man experienced severe low back pain after he fell backward 1 m off a stepladder during work. A 12th thoracic vertebral fracture with DISH was observed. As the fractured part was unstable due to a three-column injury, and the conservative treatment of resting was not successful, posterior dynamic stabilisation with a mobile PPS between T11\u2013L1 was performed the 38th day after injury. Immediately after surgery, a fracture gap was observed, but 5\u2009months later, vertebral body height was shortened by about 4 mm, and good bone fusion was observed without loosening of the screw. The mobile PPS flexibly adapts to spinal plasticity and may be useful for bone union in vertebral fractures associated with DISH.<\/jats:p>","DOI":"10.1136\/bcr-2021-242042","type":"journal-article","created":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T13:43:50Z","timestamp":1617803030000},"page":"e242042","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":4,"title":["Usefulness of dynamic stabilisation with mobile percutaneous pedicle screw for thoracic vertebral fractures in diffuse idiopathic skeletal hyperostosis"],"prefix":"10.1136","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2247-5376","authenticated-orcid":false,"given":"Yawara","family":"Eguchi","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Chiba University, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Munetaka","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Shimoshizu National Hospital, Yotsukaido, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sumihisa","family":"Orita","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Chiba University, Chiba, Japan"},{"name":"Department of Orthopaedic Surgery, Chiba University Center for Frontier Medical Engineering, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seiji","family":"Ohtori","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Chiba University, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2021,4,7]]},"reference":[{"key":"2025082801055287000_14.4.e242042.1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.jos.2016.09.011","article-title":"Ct-Based morphological analysis of spinal fractures in patients with diffuse idiopathic skeletal hyperostosis","volume":"22","author":"Okada","year":"2017","journal-title":"J Orthop Sci"},{"key":"2025082801055287000_14.4.e242042.2","doi-asserted-by":"crossref","first-page":"S57","DOI":"10.1097\/BOT.0000000000000953","article-title":"Fractures in spinal ankylosing disorders: a narrative review of disease and injury types, treatment techniques, and outcomes","volume":"31 Suppl 4","author":"Rustagi","year":"2017","journal-title":"J Orthop Trauma"},{"key":"2025082801055287000_14.4.e242042.3","doi-asserted-by":"crossref","first-page":"E458","DOI":"10.1097\/BRS.0b013e3181cc764f","article-title":"Spine fractures in patients with ankylosing spinal disorders","volume":"35","author":"Caron","year":"2010","journal-title":"Spine"},{"key":"2025082801055287000_14.4.e242042.4","doi-asserted-by":"crossref","first-page":"241","DOI":"10.5435\/JAAOS-D-14-00149","article-title":"Spinal fractures in patients with ankylosing spondylitis: etiology, diagnosis, and management","volume":"24","author":"Werner","year":"2016","journal-title":"J Am Acad Orthop Surg"},{"key":"2025082801055287000_14.4.e242042.5","first-page":"27","article-title":"Non-Fusion stabilization of the lumbar spine in the case of degenerative diseases with a dynamic pedicle screw rod","volume":"5","author":"von Strempel","year":"2006","journal-title":"Coluna\/columna"},{"key":"2025082801055287000_14.4.e242042.6","doi-asserted-by":"crossref","first-page":"1478","DOI":"10.1007\/s00586-009-1052-3","article-title":"Non-fusion instrumentation of the lumbar spine with a hinged pedicle screw rod system: an in vitro experiment","volume":"18","author":"Schmoelz","year":"2009","journal-title":"Eur Spine J"},{"key":"2025082801055287000_14.4.e242042.7","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/00008526-200103000-00013","article-title":"Hinged-Dynamic posterior device permits greater loads on the graft and similar stability as compared with its equivalent rigid device: a three-dimensional finite element assessment","volume":"13","author":"Goel","year":"2001","journal-title":"JPO Journal of Prosthetics and Orthotics"},{"key":"2025082801055287000_14.4.e242042.8","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.jocn.2020.04.043","article-title":"Pilot study of oblique lumbar interbody fusion using mobile percutaneous pedicle screw and validation by a three-dimensional finite element assessment","volume":"76","author":"Eguchi","year":"2020","journal-title":"J Clin Neurosci"},{"key":"2025082801055287000_14.4.e242042.9","doi-asserted-by":"publisher","DOI":"10.1136\/ard.9.4.321"},{"key":"2025082801055287000_14.4.e242042.10","doi-asserted-by":"publisher","DOI":"10.1148\/119.3.559"},{"key":"2025082801055287000_14.4.e242042.11","doi-asserted-by":"crossref","DOI":"10.1093\/jscr\/rjx040","article-title":"Delayed leg paraplegia associated with hyperextension injury in patients with diffuse idiopathic skeletal hyperostosis (DISH): case report and review of the literature","volume":"2017","author":"Yamamoto","year":"2017","journal-title":"J Surg Case Rep"},{"key":"2025082801055287000_14.4.e242042.12","first-page":"1","article-title":"Spontaneous symptomatic pseudoarthrosis at the L2-L3 intervertebral space with diffuse idiopathic skeletal hyperostosis: a case report","volume":"2013","author":"Hasegawa","year":"2013","journal-title":"Case Rep Orthop"},{"key":"2025082801055287000_14.4.e242042.13","doi-asserted-by":"publisher","DOI":"10.1177\/2192568217736268"},{"key":"2025082801055287000_14.4.e242042.14","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-008-0764-0"},{"key":"2025082801055287000_14.4.e242042.15","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1016\/j.wneu.2014.12.041","article-title":"In-hospital neurologic deterioration following fractures of the ankylosed spine: a single-institution experience","volume":"83","author":"Schiefer","year":"2015","journal-title":"World Neurosurg"},{"key":"2025082801055287000_14.4.e242042.16","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/00024720-200304000-00005","article-title":"Transdiscal L5-S1 screws for the fixation of isthmic spondylolisthesis: a biomechanical evaluation","volume":"16","author":"Minamide","year":"2003","journal-title":"J Spinal Disord Tech"},{"key":"2025082801055287000_14.4.e242042.17","doi-asserted-by":"crossref","first-page":"203","DOI":"10.3171\/2014.3.SPINE13665","article-title":"Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note","volume":"21","author":"Matsukawa","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"2025082801055287000_14.4.e242042.18","unstructured":"Hishiya T , Ishikawa T , Ota M . Posterior spinal fixation using penetrating endplate screws in patients with diffuse idiopathic skeletal hyperostosis-related thoracolumbar fractures. J Neurosurg Spine."},{"key":"2025082801055287000_14.4.e242042.19","doi-asserted-by":"crossref","first-page":"2206","DOI":"10.1097\/00007632-199911010-00006","article-title":"Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model","volume":"24","author":"Scifert","year":"1999","journal-title":"Spine"},{"key":"2025082801055287000_14.4.e242042.20","unstructured":"White AA , Panjabi MM . Clinical biomechanics of the spine. 2nd ed. Philadelphia: Lippincott, 1990: 88\u20139."}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2021-242042","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T08:06:00Z","timestamp":1756368360000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2021-242042"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4]]},"references-count":20,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021,4,7]]},"published-print":{"date-parts":[[2021,4]]}},"alternative-id":["10.1136\/bcr-2021-242042"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2021-242042","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2021,4]]}}}