{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T08:08:00Z","timestamp":1792483680806,"version":"4.5.0"},"reference-count":18,"publisher":"BMJ","issue":"4","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2022,4,1]]},"published-print":{"date-parts":[[2022,4]]},"abstract":"<jats:p>The definition of the mandibular angle profile is a common challenge for oral and maxillofacial surgeons. Accurate diagnosis and treatment planning are mandatory in order to properly manage soft and hard tissues. The use of several biomaterials is described in the literature. The present paper reports the treatment of a defect in the right mandibular angle in otomandibular syndrome sequelae by positioning polyetheretherketone (PEEK) patient-specific implants (PSI) in a 25-year-old patient who previously underwent orthognathic surgery. Satisfactory aesthetic results were achieved with no complications 12 months after surgery. Considering its advantageous physical properties and the low rate of postoperative complications reported in the literature, PEEK can increase the treatment options for recontouring not only the upper third and the middle third of the face, but also of the lower third, in particular in cases of large three-dimensional defects.<\/jats:p>","DOI":"10.1136\/bcr-2022-248826","type":"journal-article","created":{"date-parts":[[2022,4,12]],"date-time":"2022-04-12T12:56:56Z","timestamp":1649768216000},"page":"e248826","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":14,"title":["Mandibular recontouring with polyetheretherketone (PEEK) patient-specific implants"],"prefix":"10.1136","volume":"15","author":[{"given":"Riccardo","family":"Nocini","sequence":"first","affiliation":[{"name":"Unit of Otolaryngology, University of Verona, Verona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"D'Agostino","sequence":"additional","affiliation":[{"name":"Section of Dentistry and Maxillo-Facial Surgery, University of Verona, Verona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Trevisiol","sequence":"additional","affiliation":[{"name":"Section of Dentistry and Maxillo-Facial Surgery, University of Verona, Verona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vittorio","family":"Favero","sequence":"additional","affiliation":[{"name":"Section of Dentistry and Maxillo-Facial Surgery, University of Verona, Verona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2022,4,12]]},"reference":[{"key":"2025082802375927000_15.4.e248826.1","doi-asserted-by":"publisher","DOI":"10.1097\/01.PRS.0000056866.80665.7A"},{"key":"2025082802375927000_15.4.e248826.2","doi-asserted-by":"crossref","first-page":"1238.e1","DOI":"10.1016\/j.joms.2016.01.052","article-title":"Hydroxyapatite\/Collagen composite is a reliable material for malar augmentation","volume":"74","author":"D'Agostino","year":"2016","journal-title":"J Oral Maxillofac Surg"},{"key":"2025082802375927000_15.4.e248826.3","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1097\/SCS.0000000000000659","article-title":"Correction of facial and mandibular asymmetry using a computer aided design\/computer aided manufacturing prefabricated titanium implant","volume":"25","author":"Watson","year":"2014","journal-title":"J Craniofac Surg"},{"key":"2025082802375927000_15.4.e248826.4","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1016\/j.jcms.2015.06.043","article-title":"Primary and secondary reconstruction of complex craniofacial defects using polyetheretherketone custom-made implants","volume":"43","author":"Gerbino","year":"2015","journal-title":"J Craniomaxillofac Surg"},{"key":"2025082802375927000_15.4.e248826.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.cxom.2011.12.002"},{"key":"2025082802375927000_15.4.e248826.6","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1055\/s-0036-1581061","article-title":"Patient-Specific implant for residual facial asymmetry following Orthognathic surgery in unilateral craniofacial microsomia","volume":"9","author":"Staal","year":"2016","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"2025082802375927000_15.4.e248826.7","doi-asserted-by":"publisher","DOI":"10.1097\/00006534-200009030-00030"},{"key":"2025082802375927000_15.4.e248826.8","doi-asserted-by":"publisher","DOI":"10.1097\/00006534-199102000-00008"},{"key":"2025082802375927000_15.4.e248826.9","doi-asserted-by":"publisher","DOI":"10.1097\/00006534-199710000-00043"},{"key":"2025082802375927000_15.4.e248826.10","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.bjoms.2009.08.011","article-title":"Mandibula wing osteotomy for correction of the mandibular plane: a case report","volume":"48","author":"Triaca","year":"2010","journal-title":"Br J Oral Maxillofac Surg"},{"key":"2025082802375927000_15.4.e248826.11","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0094-1298(20)30678-7","article-title":"Mandibular angle augmentation and reduction","volume":"18","author":"Ousterhout","year":"1991","journal-title":"Clin Plast Surg"},{"key":"2025082802375927000_15.4.e248826.12","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1002\/jcp.24276","article-title":"Mesenchymal stem cells from patients to assay bone graft substitutes","volume":"228","author":"Manfrini","year":"2013","journal-title":"J Cell Physiol"},{"key":"2025082802375927000_15.4.e248826.13","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1007\/s12013-014-0374-x","article-title":"Osteoconductivity of complex biomaterials assayed by Fluorescent-Engineered osteoblast-like cells","volume":"71","author":"Manfrini","year":"2015","journal-title":"Cell Biochem Biophys"},{"key":"2025082802375927000_15.4.e248826.14","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1016\/j.jcms.2015.06.022","article-title":"Porous polyethylene implants in facial reconstruction: outcome and complications","volume":"43","author":"Ridwan-Pramana","year":"2015","journal-title":"J Craniomaxillofac Surg"},{"key":"2025082802375927000_15.4.e248826.15","doi-asserted-by":"publisher","DOI":"10.1007\/BF01570699"},{"key":"2025082802375927000_15.4.e248826.16","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1097\/SCS.0000000000006926","article-title":"Mandibular angle contouring using porous polyethylene stock or PEEK-based patient specific implants. A critical analysis","volume":"32","author":"Olate","year":"2021","journal-title":"J Craniofac Surg"},{"key":"2025082802375927000_15.4.e248826.17","doi-asserted-by":"crossref","first-page":"1969","DOI":"10.1016\/j.joms.2013.03.021","article-title":"Single-step resection and reconstruction using patient-specific implants in the treatment of benign cranio-orbital tumors","volume":"71","author":"Gerbino","year":"2013","journal-title":"J Oral Maxillofac Surg"},{"key":"2025082802375927000_15.4.e248826.18","doi-asserted-by":"crossref","first-page":"110","DOI":"10.3109\/13645701003644087","article-title":"Materials and techniques for osseous skull reconstruction","volume":"19","author":"Spetzger","year":"2010","journal-title":"Minim Invasive Ther Allied Technol"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2022-248826","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T09:38:09Z","timestamp":1756373889000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2022-248826"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4]]},"references-count":18,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2022,4,12]]},"published-print":{"date-parts":[[2022,4]]}},"alternative-id":["10.1136\/bcr-2022-248826"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2022-248826","relation":{},"ISSN":["1757-790X"],"issn-type":[{"value":"1757-790X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4]]}}}