{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T00:02:43Z","timestamp":1756339363514,"version":"3.44.0"},"reference-count":33,"publisher":"BMJ","issue":"8","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2023,8,17]]},"published-print":{"date-parts":[[2023,8]]},"abstract":"<jats:p>This case describes a young, healthy woman who developed a grade 1 biceps muscle strain after the use of automatic non-invasive blood pressure monitoring during an elective surgical procedure. She was treated conservatively with simple analgesia, physiotherapy and a sling for comfort. Follow-up conducted 1 week later revealed occasional soreness, but she had almost returned to her baseline activity. The patient made a full recovery without any residual symptoms by the end of 6 weeks. This case highlights the importance of careful monitoring to ensure that routine use of blood pressure cuffs does not cause any pressure injuries.<\/jats:p>","DOI":"10.1136\/bcr-2023-256459","type":"journal-article","created":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T12:56:25Z","timestamp":1693313785000},"page":"e256459","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Biceps muscle injury associated with non-invasive automatic blood pressure monitoring"],"prefix":"10.1136","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3161-1683","authenticated-orcid":false,"given":"Rose","family":"Nicol","sequence":"first","affiliation":[{"name":"Emergency Department, Toowoomba Hospital, Darling Downs Health, Toowoomba, Queensland, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5880-1324","authenticated-orcid":false,"given":"Ian","family":"Lin","sequence":"additional","affiliation":[{"name":"Intensive Care Department, Logan Hospital, Metro South Health, Logan, Queensland, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0104-0525","authenticated-orcid":false,"given":"Linga","family":"Prasad","sequence":"additional","affiliation":[{"name":"Anaesthetic Department, Toowoomba Hospital, Darling Downs Health, Toowoomba, Queensland, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2023,8,29]]},"reference":[{"key":"2025082700255112000_16.8.e256459.1","doi-asserted-by":"crossref","first-page":"155","DOI":"10.3109\/08037051.2015.1110935","article-title":"Comparison between invasive and non-invasive blood pressure in young, middle and old age","volume":"25","author":"Liu","year":"2016","journal-title":"Blood Press"},{"key":"2025082700255112000_16.8.e256459.2","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.jopan.2016.12.007","article-title":"Eliminating medical device-related pressure injury from blood pressure cuffs during continuous monitoring in the perioperative setting: a novel approach","volume":"33","author":"Owens","year":"2018","journal-title":"J Perianesth Nurs"},{"key":"2025082700255112000_16.8.e256459.3","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199007000-00030"},{"key":"2025082700255112000_16.8.e256459.4","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5049.79879"},{"key":"2025082700255112000_16.8.e256459.5","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1038\/hr.2016.184","article-title":"Impact of cuff positioning on blood pressure measurement accuracy: may a specially designed cuff make a difference","volume":"40","author":"Bilo","year":"2017","journal-title":"Hypertens Res"},{"key":"2025082700255112000_16.8.e256459.6","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1093\/ajh\/hpac104","article-title":"Blood pressure cuff sizes for adults in the United States: national health and nutrition examination survey, 2015-2020","volume":"35","author":"Jackson","year":"2022","journal-title":"Am J Hypertens"},{"key":"2025082700255112000_16.8.e256459.7","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.323.7318.919"},{"key":"2025082700255112000_16.8.e256459.8","doi-asserted-by":"publisher","DOI":"10.3109\/17453678809149401"},{"key":"2025082700255112000_16.8.e256459.9","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1007\/s11552-010-9312-6","article-title":"Tourniquet use in upper limb surgery","volume":"6","author":"Oragui","year":"2011","journal-title":"Hand (N Y)"},{"key":"2025082700255112000_16.8.e256459.10","unstructured":"Anaesthetists AaNZCo . PG18(A) guideline on monitoring during anaesthesia: ANZCA FPM. 2017 Available: https:\/\/www.anzca.edu.au\/getattachment\/0c2d9717-fa82-4507-a3d6-3533d8fa844d\/PS18-Guideline-on-monitoring-during-anaesthesia"},{"key":"2025082700255112000_16.8.e256459.11","doi-asserted-by":"crossref","first-page":"169","DOI":"10.4103\/0259-1162.181430","article-title":"Accuracy in blood pressure monitoring: the effect of noninvasive blood pressure cuff inflation on intra-arterial blood pressure values","volume":"11","author":"Sheshadri","year":"2017","journal-title":"Anesth Essays Res"},{"key":"2025082700255112000_16.8.e256459.12","doi-asserted-by":"crossref","DOI":"10.1136\/bcr-2019-231541","article-title":"Petechial purpuric rash after non-invasive blood pressure measurement: rumpel-leede sign","volume":"12","author":"van Rhijn","year":"2019","journal-title":"BMJ Case Rep"},{"key":"2025082700255112000_16.8.e256459.13","doi-asserted-by":"crossref","unstructured":"Lambdin JT , Mackenzie C . Rumpel-Leede phenomenon in a patient with adult-onset still's disease. BMJ Case Rep 2017;2017. doi:10.1136\/bcr-2016-217290","DOI":"10.1136\/bcr-2016-217290"},{"key":"2025082700255112000_16.8.e256459.14","doi-asserted-by":"publisher","DOI":"10.4097\/kjae.2010.59.3.203"},{"key":"2025082700255112000_16.8.e256459.15","doi-asserted-by":"crossref","first-page":"1345","DOI":"10.1213\/00000539-199612000-00040","article-title":"Acute biceps compartment syndrome associated with the use of a noninvasive blood pressure monitor","volume":"83","author":"Sutin","year":"1996","journal-title":"Anesth Analg"},{"key":"2025082700255112000_16.8.e256459.16","doi-asserted-by":"publisher","DOI":"10.1007\/BF00858363"},{"key":"2025082700255112000_16.8.e256459.17","first-page":"5653481","article-title":"Perioperative automated noninvasive blood pressure- (NIBP-) related peripheral nerve injuries: an anesthetist's dilemma-a case report and review of the literature","volume":"2020","author":"Elmatite","year":"2020","journal-title":"Case Rep Anesthesiol"},{"key":"2025082700255112000_16.8.e256459.18","doi-asserted-by":"publisher","DOI":"10.1016\/S0952-8180(01)00262-8"},{"key":"2025082700255112000_16.8.e256459.19","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/S1875-4597(09)60043-6","article-title":"Acute radial nerve injury associated with an automatic blood pressure monitor","volume":"47","author":"Swei","year":"2009","journal-title":"Acta Anaesthesiol Taiwan"},{"key":"2025082700255112000_16.8.e256459.20","doi-asserted-by":"crossref","first-page":"217","DOI":"10.4097\/kjae.2009.57.2.217","article-title":"Radial nerve injury due to automatic blood pressure monitoring: a case report","volume":"57","author":"Kim","year":"2009","journal-title":"Korean J Anesthesiol"},{"key":"2025082700255112000_16.8.e256459.21","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1213\/00000539-198109000-00013","article-title":"Ulnar nerve palsy possibly related to use of automatically cycled blood pressure cuff","volume":"60","author":"Sy","year":"1981","journal-title":"Anesth Analg"},{"key":"2025082700255112000_16.8.e256459.22","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5413.98824"},{"key":"2025082700255112000_16.8.e256459.23","doi-asserted-by":"publisher","DOI":"10.1093\/bjaceaccp\/mkp002"},{"key":"2025082700255112000_16.8.e256459.24","doi-asserted-by":"crossref","first-page":"424","DOI":"10.4103\/0970-9185.168174","article-title":"Tourniquet application during anesthesia: \"what we need to know","volume":"32","author":"Kumar","year":"2016","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"2025082700255112000_16.8.e256459.25","first-page":"119","article-title":"A case of crush syndrome resulting from continuous compression of the upper arm by automatically cycled blood pressure cuff","volume":"46","author":"Yamada","year":"1997","journal-title":"Masui"},{"key":"2025082700255112000_16.8.e256459.26","first-page":"136","article-title":"Skin necrosis in a critically ill patient due to a blood pressure cuff","volume":"52","author":"Devbhandari","year":"2006","journal-title":"J Postgrad Med"},{"key":"2025082700255112000_16.8.e256459.27","first-page":"141","article-title":"Nondisposable sphygmomanometer cuffs harbor frequent bacterial colonization and significant contamination by organic and inorganic matter","volume":"64","author":"Base-Smith","year":"1996","journal-title":"AANA J"},{"key":"2025082700255112000_16.8.e256459.28","doi-asserted-by":"crossref","unstructured":"Pandey S , Sinha RJ , Sharma D , et al . Delayed pressure urticaria due to non-invasive blood pressure monitoring in a previously non-atopic man. BMJ Case Reports 2018:bcr\u20132018 doi:10.1136\/bcr-2018-227267","DOI":"10.1136\/bcr-2018-227267"},{"key":"2025082700255112000_16.8.e256459.29","doi-asserted-by":"crossref","first-page":"2411","DOI":"10.1001\/jama.1985.03360170051020","article-title":"Phlebitis associated with noninvasive 24-hour ambulatory blood pressure monitor","volume":"254","author":"Creevy","year":"1985","journal-title":"JAMA"},{"key":"2025082700255112000_16.8.e256459.30","unstructured":"Karunaharamoorthy A . Biceps brachii muscle. 2023 Available: https:\/\/www.kenhub.com\/en\/library\/anatomy\/biceps-brachii-muscle"},{"key":"2025082700255112000_16.8.e256459.31","unstructured":"Health M . Bicep tear or strain. 2023. Available: https:\/\/www.mercy.com\/health-care-services\/orthopedics-sports-medicine-spine\/specialties\/shoulder-upper-arm\/conditions\/bicep-tear-strain#:~:text=Grade%201%20%E2%80%94%20minor%20injury%20that,may%20require%20surgery%20to%20repair"},{"key":"2025082700255112000_16.8.e256459.32","unstructured":"Strain DTB . 2022. Available: https:\/\/physioadvisor.com.au\/injuries\/shoulder\/bicep-strain"},{"key":"2025082700255112000_16.8.e256459.33","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1046\/j.1365-2044.2001.02180.x","article-title":"Blood pressure measurement in volunteers with and without padding between the cuff and the skin","volume":"56","author":"Archer","year":"2001","journal-title":"Anaesthesia"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2023-256459","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T07:26:02Z","timestamp":1756279562000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2023-256459"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8]]},"references-count":33,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2023,8,29]]},"published-print":{"date-parts":[[2023,8]]}},"alternative-id":["10.1136\/bcr-2023-256459"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2023-256459","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2023,8]]}}}