{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T08:10:22Z","timestamp":1756282222600,"version":"3.44.0"},"reference-count":16,"publisher":"BMJ","issue":"1","funder":[{"DOI":"10.13039\/501100017510","name":"UK Dementia Research Institute","doi-asserted-by":"publisher","award":["JMW"],"award-info":[{"award-number":["JMW"]}],"id":[{"id":"10.13039\/501100017510","id-type":"DOI","asserted-by":"publisher"}]},{"name":"NHS Lothian Research and Development Office","award":["MJT"],"award-info":[{"award-number":["MJT"]}]},{"name":"Theirworld","award":["Edinburgh Imaging Facility at the Royal Infirmary","Theirworld Edinburgh Birth Cohort - initiation."],"award-info":[{"award-number":["Edinburgh Imaging Facility at the Royal Infirmary","Theirworld Edinburgh Birth Cohort - initiation."]}]},{"DOI":"10.13039\/501100000377","name":"Dunhill Medical Trust","doi-asserted-by":"publisher","award":["Edinburgh Imaging Facility at the Royal Infirmary"],"award-info":[{"award-number":["Edinburgh Imaging Facility at the Royal Infirmary"]}],"id":[{"id":"10.13039\/501100000377","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100010269","name":"Wellcome Trust","doi-asserted-by":"publisher","award":["Edinburgh Imaging Facility at the Royal Infirmary"],"award-info":[{"award-number":["Edinburgh Imaging Facility at the Royal Infirmary"]}],"id":[{"id":"10.13039\/100010269","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Edinburgh and Lothians Research Foundation","award":["Edinburgh Imaging Facility at the Royal Infirmary"],"award-info":[{"award-number":["Edinburgh Imaging Facility at the Royal Infirmary"]}]},{"DOI":"10.13039\/501100000265","name":"Medical Research Council","doi-asserted-by":"publisher","award":["MR\/X003434\/1 - MRI at five years for the Theirworl"],"award-info":[{"award-number":["MR\/X003434\/1 - MRI at five years for the Theirworl"]}],"id":[{"id":"10.13039\/501100000265","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004350","name":"Studienstiftung des Deutschen Volkes","doi-asserted-by":"publisher","award":["SA"],"award-info":[{"award-number":["SA"]}],"id":[{"id":"10.13039\/501100004350","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000848","name":"University of Edinburgh","doi-asserted-by":"publisher","award":["Edinburgh Imaging Facility at the Royal Infirmary"],"award-info":[{"award-number":["Edinburgh Imaging Facility at the Royal Infirmary"]}],"id":[{"id":"10.13039\/501100000848","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100019741","name":"Muir Maxwell Trust","doi-asserted-by":"publisher","award":["Edinburgh Imaging Facility at the Royal Infirmary"],"award-info":[{"award-number":["Edinburgh Imaging Facility at the Royal Infirmary"]}],"id":[{"id":"10.13039\/501100019741","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2024,1,15]]},"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:p>Metallic foreign bodies (FBs) are a safety risk during MRI. Here, we describe a boy in early childhood with an unexpected ferromagnetic FB discovered during a research brain MRI. Safety precautions included written and oral safety screening checklists and visual check during a structured safety pause. During introduction to the scanner, he was lifted to look at the bore. Staff became aware of an object flying into the bore. The child reached for his ear, and a 5\u2009mm diameter ball bearing was found in the bore. The child had no external injury. We have introduced a 0.1 T handheld magnet to check for metallic FBs not known to the parent. FBs are a common paediatric emergency department presentation, particularly in younger children or those with cognitive or behavioural problems. This case highlights the importance of safety screening in paediatric MRI scanning, along with its fallibility.<\/jats:p>","DOI":"10.1136\/bcr-2023-258969","type":"journal-article","created":{"date-parts":[[2024,1,25]],"date-time":"2024-01-25T02:07:18Z","timestamp":1706148438000},"page":"e258969","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["An unexpected ferromagnetic foreign body in a paediatric research participant undergoing 3T MRI"],"prefix":"10.1136","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8177-1450","authenticated-orcid":false,"given":"Katie","family":"Mckinnon","sequence":"first","affiliation":[{"name":"Centre for Reproductive Health, Institute for Regeneration and Repair, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-3732-4135","authenticated-orcid":false,"given":"Charlotte","family":"Jardine","sequence":"additional","affiliation":[{"name":"Edinburgh Imaging Facility, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-2417-2750","authenticated-orcid":false,"given":"Gayle","family":"Barclay","sequence":"additional","affiliation":[{"name":"Edinburgh Imaging Facility, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7858-9917","authenticated-orcid":false,"given":"Michael J","family":"Thrippleton","sequence":"additional","affiliation":[{"name":"Edinburgh Imaging Facility, University of Edinburgh, Edinburgh, UK"},{"name":"Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-5117-1187","authenticated-orcid":false,"given":"Selina","family":"Abel","sequence":"additional","affiliation":[{"name":"School of Philosophy, Psychology, and Language Sciences, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9812-6642","authenticated-orcid":false,"given":"Joanna M","family":"Wardlaw","sequence":"additional","affiliation":[{"name":"Edinburgh Imaging Facility, University of Edinburgh, Edinburgh, UK"},{"name":"Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0490-0845","authenticated-orcid":false,"given":"Mark E","family":"Bastin","sequence":"additional","affiliation":[{"name":"Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4505-8869","authenticated-orcid":false,"given":"Heather C","family":"Whalley","sequence":"additional","affiliation":[{"name":"Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3444-805X","authenticated-orcid":false,"given":"Hilary","family":"Richardson","sequence":"additional","affiliation":[{"name":"School of Philosophy, Psychology, and Language Sciences, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3904-8960","authenticated-orcid":false,"given":"James P","family":"Boardman","sequence":"additional","affiliation":[{"name":"Centre for Reproductive Health, Institute for Regeneration and Repair, University of Edinburgh, Edinburgh, UK"},{"name":"Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2024,1,24]]},"reference":[{"key":"2025082700320865000_17.1.e258969.1","unstructured":"Medicines and Healthcare Products Regulatory Agency . Safety guidelines for magnetic resonance imaging equipment in clinical use. UK Government, 2021."},{"key":"2025082700320865000_17.1.e258969.2","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2019-035854","article-title":"Impact of preterm birth on brain development and long-term outcome: protocol for a cohort study in Scotland","volume":"10","author":"Boardman","year":"2020","journal-title":"BMJ Open"},{"key":"2025082700320865000_17.1.e258969.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2012.11.013"},{"key":"2025082700320865000_17.1.e258969.4","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.ajoc.2017.06.010","article-title":"Metallic Intraocular foreign body as detected by magnetic resonance imaging without complications\u2013 a case report","volume":"7","author":"Platt","year":"2017","journal-title":"Am J Ophthalmol Case Rep"},{"key":"2025082700320865000_17.1.e258969.5","doi-asserted-by":"crossref","DOI":"10.1259\/bjro.20180006","article-title":"A 3-year review of MRI safety incidents within a UK independent sector provider of diagnostic services","volume":"1","author":"Hudson","year":"2019","journal-title":"BJR|Open"},{"key":"2025082700320865000_17.1.e258969.6","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.pnmrs.2007.01.003","article-title":"Magnetic resonance imaging safety issues including an analysis of recorded incidents within the UK","volume":"51","author":"Dewilde","year":"2007","journal-title":"Progress in Nuclear Magnetic Resonance Spectroscopy"},{"key":"2025082700320865000_17.1.e258969.7","first-page":"1185","article-title":"Foreign bodies in the ear, nose, and throat","volume":"76","author":"Heim","year":"2007","journal-title":"Am Fam Physician"},{"key":"2025082700320865000_17.1.e258969.8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1308\/rcsann.2018.0115","article-title":"Will children ever learn? Removal of nasal and aural foreign bodies: a study of hospital episode statistics","volume":"100","author":"Morris","year":"2018","journal-title":"Ann R Coll Surg Engl"},{"key":"2025082700320865000_17.1.e258969.9","doi-asserted-by":"publisher","DOI":"10.1542\/peds.101.4.638"},{"key":"2025082700320865000_17.1.e258969.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2013.05.012"},{"key":"2025082700320865000_17.1.e258969.11","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.ijporl.2008.10.008","article-title":"Foreign bodies of the ear and nose in children and its correlation with right or left handed children","volume":"73","author":"Peridis","year":"2009","journal-title":"Int J Pediatr Otorhinolaryngol"},{"key":"2025082700320865000_17.1.e258969.12","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1097\/PEC.0000000000002960","article-title":"The effect of developmental delay and autism spectrum disorder on external auditory canal foreign body extraction","volume":"39","author":"Nguyen","year":"2023","journal-title":"Pediatr Emerg Care"},{"key":"2025082700320865000_17.1.e258969.13","article-title":"Foreign body ingestion in neurologically impaired children: a challenging diagnosis and management in pediatric surgery","volume":"8","author":"Destro","year":"2021","journal-title":"Children (Basel)"},{"key":"2025082700320865000_17.1.e258969.14","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24011"},{"key":"2025082700320865000_17.1.e258969.15","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.12.10332"},{"key":"2025082700320865000_17.1.e258969.16","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1007\/s00247-019-04359-8","article-title":"Practical considerations for establishing and maintaining a magnetic resonance imaging safety program in a pediatric practice","volume":"49","author":"Chandra","year":"2019","journal-title":"Pediatr Radiol"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2023-258969","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T07:32:23Z","timestamp":1756279943000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2023-258969"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1,24]]},"published-print":{"date-parts":[[2024,1]]}},"alternative-id":["10.1136\/bcr-2023-258969"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2023-258969","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2024,1]]}}}