{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T00:04:13Z","timestamp":1756339453530,"version":"3.44.0"},"reference-count":11,"publisher":"BMJ","issue":"11","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2024,11,11]]},"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:p>While close-range shotgun injuries may clinically appear similar to gunshot wounds from rifles or handguns, they are important to differentiate as they require special consideration. We present a case of a male in his 20s who sustained a close-range shotgun wound to the right lower extremity and was subsequently found to have a retained, radiolucent shotgun wad deep within the wound bed. Identification and removal of shotgun wads are of paramount importance, as failure to do so may lead to downstream secondary infectious complications.<\/jats:p>","DOI":"10.1136\/bcr-2024-260807","type":"journal-article","created":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T03:25:29Z","timestamp":1732677929000},"page":"e260807","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Shotgun injury: don\u2019t forget the wad"],"prefix":"10.1136","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3138-2518","authenticated-orcid":false,"given":"Shahrose","family":"Rahman","sequence":"first","affiliation":[{"name":"Department of Surgery, Oregon Health & Science University, Portland, Oregon, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3672-5735","authenticated-orcid":false,"given":"Ranish K","family":"Patel","sequence":"additional","affiliation":[{"name":"Department of Surgery, Oregon Health & Science University, Portland, Oregon, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7350-8222","authenticated-orcid":false,"given":"John X","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Surgery, Oregon Health & Science University, Portland, Oregon, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karen","family":"Brasel","sequence":"additional","affiliation":[{"name":"Department of Surgery, Oregon Health & Science University, Portland, Oregon, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2024,11,26]]},"reference":[{"key":"2025082707123700000_17.11.e260807.1","doi-asserted-by":"publisher","DOI":"10.1007\/s12024-009-9096-6"},{"key":"2025082707123700000_17.11.e260807.2","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.jemermed.2020.02.021","article-title":"Shotgun Wounds: Nationwide Trends in Epidemiology, Injury Patterns, and Outcomes from US Trauma Centers","volume":"58","author":"Schellenberg","year":"2020","journal-title":"J Emerg Med"},{"key":"2025082707123700000_17.11.e260807.3","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1007\/s00068-019-01168-4","article-title":"The diagnostic dilemma of shotgun injuries","volume":"46","author":"Schellenberg","year":"2020","journal-title":"Eur J Trauma Emerg Surg"},{"key":"2025082707123700000_17.11.e260807.4","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1520\/JFS14876J","article-title":"Ballistic characterization of the Remington Premier Copper Solid sabot shotgun slug","volume":"45","author":"Ward","year":"2000","journal-title":"J Forensic Sci"},{"key":"2025082707123700000_17.11.e260807.5","doi-asserted-by":"crossref","DOI":"10.2214\/ajr.174.2.1740400","article-title":"CT appearance of shotgun wadding","volume":"174","author":"Kemper","year":"2000","journal-title":"AJR Am J Roentgenol"},{"key":"2025082707123700000_17.11.e260807.6","unstructured":"DiMaio V . Gunshot Wounds: Practical Aspects of Firearms, Ballistics, and Forensic Techniques. 3rd edn. Taylor & Francis, 2015:212\u20133."},{"key":"2025082707123700000_17.11.e260807.7","doi-asserted-by":"crossref","first-page":"2521","DOI":"10.1111\/1556-4029.14814","article-title":"Shotgun slug wads as a marker of range of fire: A case report and novel firearm testing data","volume":"66","author":"Multan","year":"2021","journal-title":"J Forensic Sci"},{"key":"2025082707123700000_17.11.e260807.8","first-page":"35","article-title":"Shotgun gunshot injury--shotgun slugs","volume":"53","author":"Hejna","year":"2008","journal-title":"Soud Lek"},{"key":"2025082707123700000_17.11.e260807.9","first-page":"236","article-title":"Removal of the wadding from the wound in shotgun-pellet injuries","volume":"36","author":"Esenkaya","year":"2002","journal-title":"Acta Orthop Traumatol Turc"},{"key":"2025082707123700000_17.11.e260807.10","doi-asserted-by":"crossref","DOI":"10.1186\/s40792-021-01238-z","article-title":"A rare case of retained sabot after close-range shotgun injury","volume":"7","author":"Flippin","year":"2021","journal-title":"Surg Case Rep"},{"key":"2025082707123700000_17.11.e260807.11","first-page":"40","article-title":"Shotgun wound management: a comparison of slug and pellet injuries","volume":"97","author":"Davis","year":"1998","journal-title":"WMJ"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2024-260807","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T14:12:42Z","timestamp":1756303962000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2024-260807"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":11,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2024,11,26]]},"published-print":{"date-parts":[[2024,11]]}},"alternative-id":["10.1136\/bcr-2024-260807"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2024-260807","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2024,11]]}}}