{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T15:28:12Z","timestamp":1781796492949,"version":"3.54.5"},"reference-count":29,"publisher":"BMJ","issue":"4","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2025,3,25]]},"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:p>A young child presented with redness and blurred vision in his right eye following a history of blunt trauma with a ball. On examination, he was found to have an isolated posterior capsule rupture (PCR) with cataract formation. A phacoaspiration surgery was performed, and a foldable three-piece intraocular lens (IOL) was implanted in the sulcus with posterior optic capture. The child was reviewed periodically up to 6 months postoperatively and had a vision of 20\/25 with a well-centred IOL. Isolated PCR due to blunt trauma is a rare finding. Several factors determine the management of these cases, especially in children. Our case highlights the evaluation and surgical management of a patient in the amblyogenic age group to achieve the best possible visual outcome.<\/jats:p>","DOI":"10.1136\/bcr-2024-263460","type":"journal-article","created":{"date-parts":[[2025,4,25]],"date-time":"2025-04-25T04:15:18Z","timestamp":1745554518000},"page":"e263460","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Isolated posterior capsule rupture post blunt trauma"],"prefix":"10.1136","volume":"18","author":[{"given":"Prolima","family":"Thacker","sequence":"first","affiliation":[{"name":"Ophthalmology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Himali","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Ophthalmology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2577-9383","authenticated-orcid":false,"given":"Richa","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Ophthalmology, All India Institute of Medical Sciences, Gorakhpur, Gorakhpur, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Preeti","family":"Gupta","sequence":"additional","affiliation":[{"name":"Ophthalmology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,4,24]]},"reference":[{"key":"2025082712573226000_18.4.e263460.1","doi-asserted-by":"crossref","first-page":"2105","DOI":"10.1002\/ccr3.3956","article-title":"Isolated posterior capsule rupture after blunt eye injury","volume":"9","author":"Elksnis","year":"2021","journal-title":"Clin Case Rep"},{"key":"2025082712573226000_18.4.e263460.2","doi-asserted-by":"crossref","first-page":"197","DOI":"10.4274\/tjo.85547","article-title":"Isolated Anterior Lens Capsule Rupture Secondary to Blunt Trauma: Pathophysiology and Treatment","volume":"46","author":"Mangan","year":"2016","journal-title":"tjo"},{"key":"2025082712573226000_18.4.e263460.3","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/0002-9394(63)92943-X","article-title":"COUP-CONTRECOUP MECHANISM OF OCULAR INJURIES","volume":"56","author":"WOLTER","year":"1963","journal-title":"Am J Ophthalmol"},{"key":"2025082712573226000_18.4.e263460.4","doi-asserted-by":"crossref","first-page":"338","DOI":"10.3928\/1542-8877-19980401-16","article-title":"Isolated Posterior Capsule Rupture in Blunt Trauma: Pathogenesis and Management","volume":"29","author":"Rao","year":"1998","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"2025082712573226000_18.4.e263460.5","doi-asserted-by":"crossref","first-page":"422","DOI":"10.3928\/1542-8877-19970501-10","article-title":"Traumatic Cataract and Wieger\u2019s Ligament","volume":"28","author":"Campanella","year":"1997","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"2025082712573226000_18.4.e263460.6","first-page":"388","article-title":"Types of posterior capsular breaks and their surgical implications","volume":"22","author":"Angra","year":"1991","journal-title":"Ophthalmic Surg"},{"key":"2025082712573226000_18.4.e263460.7","doi-asserted-by":"crossref","first-page":"2403","DOI":"10.2147\/OPTH.S73990","article-title":"Isolated posterior capsular rupture following blunt head trauma","volume":"8","author":"Mansour","year":"2014","journal-title":"Clin Ophthalmol"},{"key":"2025082712573226000_18.4.e263460.8","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1016\/j.jcrs.2006.02.011","article-title":"Traumatic rupture of the posterior capsule resulting in complete posterior prolapse of the lens with subsequent resolution of high myopia","volume":"32","author":"El-Gendy","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"2025082712573226000_18.4.e263460.9","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/S0886-3350(98)80146-6","article-title":"Traumatic cataract with a ruptured posterior capsule from a nonpenetrating ocular injury","volume":"24","author":"Yasukawa","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"2025082712573226000_18.4.e263460.10","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/S0886-3350(97)80167-8","article-title":"Posterior capsule rupture by blunt ocular trauma","volume":"23","author":"Saika","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"2025082712573226000_18.4.e263460.11","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/S0886-3350(98)80213-7","article-title":"Posterior capsule rupture after blunt trauma","volume":"24","author":"Thomas","year":"1998","journal-title":"J CataractRefract Surg"},{"key":"2025082712573226000_18.4.e263460.12","doi-asserted-by":"crossref","first-page":"140","DOI":"10.3341\/kjo.2001.15.2.140","article-title":"A case of isolated posterior capsule rupture and traumatic cataract caused by blunt ocular trauma","volume":"15","author":"Lee","year":"2001","journal-title":"Korean J Ophthalmol"},{"key":"2025082712573226000_18.4.e263460.13","doi-asserted-by":"crossref","first-page":"1666","DOI":"10.1016\/j.jcrs.2004.12.062","article-title":"Management of traumatic posterior capsular rupture: Corneal approach with high speed vitrector","volume":"31","author":"Li","year":"2005","journal-title":"J CataractRefract Surg"},{"key":"2025082712573226000_18.4.e263460.14","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.jcrs.2006.01.057","article-title":"Implantation of foldable intraocular lens with anterior optic capture in isolated posterior capsule rupture","volume":"32","author":"Por","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"2025082712573226000_18.4.e263460.15","doi-asserted-by":"crossref","first-page":"236","DOI":"10.4103\/0301-4738.49404","article-title":"Scheimpflug imaging of pediatric posterior capsule rupture","volume":"57","author":"Grewal","year":"2009","journal-title":"Indian J Ophthalmol"},{"key":"2025082712573226000_18.4.e263460.16","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1016\/S0002-9394(00)00551-1","article-title":"Epilenticular intraocular lens implantation in traumatic cataract with a ruptured posterior capsule","volume":"130","author":"Pavlovic","year":"2000","journal-title":"Am J Ophthalmol"},{"key":"2025082712573226000_18.4.e263460.17","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1016\/j.jcrs.2005.05.016","article-title":"Implantation of foldable intraocular lens with anterior optic capture in isolated posterior capsule rupture","volume":"31","author":"Pushker","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"2025082712573226000_18.4.e263460.18","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1016\/S0886-3350(00)00372-2","article-title":"Posterior capsule rupture after a paint-pellet injury","volume":"26","author":"Rosen","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"2025082712573226000_18.4.e263460.19","first-page":"305","article-title":"Posterior capsule rupture with herniation of lens fragment following blunt ocular trauma","volume":"9","author":"Choudhary","year":"2016","journal-title":"Int Med Case Rep J"},{"key":"2025082712573226000_18.4.e263460.20","article-title":"Management of Traumatic Cataract with Posterior Capsular Rupture: A Case Report and In Vitro Model Study","volume":"2017","author":"Wan","year":"2017","journal-title":"Case Rep Ophthalmol Med"},{"key":"2025082712573226000_18.4.e263460.21","doi-asserted-by":"crossref","DOI":"10.1016\/j.ajoc.2020.100742","article-title":"Femtosecond laser-assisted cataract surgery in management of posterior capsule tear following blunt trauma: Case report and review of literature","volume":"19","author":"Prager","year":"2020","journal-title":"Am J Ophthalmol Case Rep"},{"key":"2025082712573226000_18.4.e263460.22","doi-asserted-by":"crossref","unstructured":"Elksnis E , Vanags J , ka ED , et al . An isolated posterior capsule rupture after blunt eye injury: management of traumatic cataract case. Preprints [Preprint] 2020. doi:10.22541\/au.159605215.57735106","DOI":"10.22541\/au.159605215.57735106"},{"key":"2025082712573226000_18.4.e263460.23","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1016\/S0002-9394(03)00386-6","article-title":"Visualization of posterior lens capsule integrity by 20-MHz ultrasound probe in ocular trauma","volume":"136","author":"Nguyen","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"2025082712573226000_18.4.e263460.24","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.ajo.2011.05.038","article-title":"Evaluation of posterior lens capsule by 20-MHz ultrasound probe in traumatic cataract","volume":"153","author":"Tabatabaei","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"2025082712573226000_18.4.e263460.25","first-page":"1152","article-title":"Comparison of 25 MHz and 50 MHz ultrasound biomicroscopy for imaging of the lens and its related diseases","volume":"11","author":"Shi","year":"2018","journal-title":"Int J Ophthalmol"},{"key":"2025082712573226000_18.4.e263460.26","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/j.jcrs.2012.11.017","article-title":"Preoperative detection of posterior capsule tear with ultrasound biomicroscopy in traumatic cataract","volume":"39","author":"Kucukevcilioglu","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"2025082712573226000_18.4.e263460.27","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.03.033"},{"key":"2025082712573226000_18.4.e263460.28","doi-asserted-by":"crossref","first-page":"480","DOI":"10.3928\/15428877-20120830-02","article-title":"Reverse Optic Capture of the Single-Piece Acrylic Intraocular Lens in Eyes With Posterior Capsule Rupture","volume":"43","author":"Jones","year":"2012","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"2025082712573226000_18.4.e263460.29","unstructured":"Weiner G . Reverse optic capture after posterior capsular rupture.Title. EyeNet Mag 2016;29\u201331. Available: https:\/\/www.aao.org\/eyene t\/article\/reverse-optic-capture-after-posterior-capsular-rup"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2024-263460","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T19:57:42Z","timestamp":1756324662000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2024-263460"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":29,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,4,24]]},"published-print":{"date-parts":[[2025,4]]}},"alternative-id":["10.1136\/bcr-2024-263460"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2024-263460","relation":{},"ISSN":["1757-790X"],"issn-type":[{"value":"1757-790X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]}}}