{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,29]],"date-time":"2025-08-29T00:03:45Z","timestamp":1756425825036,"version":"3.44.0"},"reference-count":15,"publisher":"BMJ","issue":"3","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2025,3,20]]},"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:p>An octogenarian patient with a medical history of hypertension and prior stroke (baseline modified Rankin Scale score of 1) presented with acute onset left-sided hemiplegia and neglect and was found to have a right middle cerebral artery M1 occlusion, likely from an embolic clot as there was no hint of intracranial atherosclerosis or dissection in the CT scan. He underwent emergent EVT using direct aspiration technique via a novel super large-bore 0.092-inch ID catheter, which was positioned in the M1 segment. This is the first clinical report of using a 0.092-inch ID catheter in the M1 segment, which resulted in full recanalisation (thrombolysis in cerebral infarction score 3 (TICI3)) of the artery without any adverse events. The patient had significant early clinical improvement, and a follow-up imaging revealed a relatively small infarct size and no haemorrhagic complications. Utilisation of super large-bore 0.092-inch ID catheter for direct aspiration in proximal large vessel occlusion might further optimise the efficacy of the aspiration pass by increasing the aspiration force and inducing local flow arrest.<\/jats:p>","DOI":"10.1136\/bcr-2024-264039","type":"journal-article","created":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T08:23:03Z","timestamp":1743409383000},"page":"e264039","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["First in-human use of super large-bore novel 0.092-inch catheter positioned in M1 segment of middle cerebral artery for aspiration thrombectomy"],"prefix":"10.1136","volume":"18","author":[{"given":"Amol","family":"Mehta","sequence":"first","affiliation":[{"name":"Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4320-0021","authenticated-orcid":false,"given":"Jennifer Morgan","family":"Watchmaker","sequence":"additional","affiliation":[{"name":"Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7084-2567","authenticated-orcid":false,"given":"Preethi","family":"Reddi","sequence":"additional","affiliation":[{"name":"Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2971-6216","authenticated-orcid":false,"given":"Shahram","family":"Majidi","sequence":"additional","affiliation":[{"name":"Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2025,3,31]]},"reference":[{"key":"2025082802521006000_18.3.e264039.1","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/j.wneu.2022.08.041","article-title":"Dawn of a New Era: Super Large-Bore Aspiration Catheters for Complete Clot Ingestion During Thrombectomy for Large-Vessel Occlusions","volume":"167","author":"Kuhn","year":"2022","journal-title":"World Neurosurg"},{"key":"2025082802521006000_18.3.e264039.2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016218"},{"key":"2025082802521006000_18.3.e264039.3","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2020-016780.rep","article-title":"Republished: First clinical report of aspiration through a novel 0.088-inch catheter positioned in the M1 middle cerebral artery for ELVO thrombectomy","volume":"13","author":"Gershon","year":"2021","journal-title":"J NeuroIntervent Surg"},{"key":"2025082802521006000_18.3.e264039.4","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-017316"},{"key":"2025082802521006000_18.3.e264039.5","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2022-018806"},{"key":"2025082802521006000_18.3.e264039.6","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-018318"},{"key":"2025082802521006000_18.3.e264039.7","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1177\/1591019920982219","article-title":"Preliminary experience with 088 large bore intracranial catheters during stroke thrombectomy","volume":"27","author":"Nogueira","year":"2021","journal-title":"Interv Neuroradiol"},{"key":"2025082802521006000_18.3.e264039.8","doi-asserted-by":"crossref","unstructured":"Dabus G , Puri AS , McGuinness B , et al . A prospective, randomized, controlled, interventional clinical trial to evaluate the safety and efficacy of the medical monopoint reperfusion system for aspiration thrombectomy in acute ischemic stroke patients (SUMMIT MAX): Trial rationale and design. Interv Neuroradiol 2024.:15910199241270711. doi:10.1177\/15910199241270711","DOI":"10.1177\/15910199241270711"},{"key":"2025082802521006000_18.3.e264039.9","article-title":"Thrombectomy using Zoom Reperfusion System in pediatric acute ischemic strokes: Case series and literature review","volume":"2","author":"Singh","year":"2024","journal-title":"Neuroradiol J"},{"key":"2025082802521006000_18.3.e264039.10","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2017-013702"},{"key":"2025082802521006000_18.3.e264039.11","doi-asserted-by":"crossref","unstructured":"Dolia JN , Mohammaden MH , Tarek MA , et al . Structural Analysis of Aspiration Catheters and Procedural Outcomes: An Analysis of the SVIN Registry. SVIN 2024;4. doi:10.1161\/SVIN.123.001214","DOI":"10.1161\/SVIN.123.001214"},{"key":"2025082802521006000_18.3.e264039.12","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5825"},{"key":"2025082802521006000_18.3.e264039.13","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2017.9644"},{"key":"2025082802521006000_18.3.e264039.14","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(19)30297-1"},{"key":"2025082802521006000_18.3.e264039.15","doi-asserted-by":"crossref","first-page":"15910199241284792","DOI":"10.1177\/15910199241284792","article-title":"FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions","volume":"23","author":"Alexander","year":"2024","journal-title":"Interv Neuroradiol"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2024-264039","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T09:52:19Z","timestamp":1756374739000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2024-264039"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":15,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,3,31]]},"published-print":{"date-parts":[[2025,3]]}},"alternative-id":["10.1136\/bcr-2024-264039"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2024-264039","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2025,3]]}}}