{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T20:55:58Z","timestamp":1790974558850,"version":"4.1.0"},"reference-count":12,"publisher":"BMJ","issue":"3","license":[{"start":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T00:00:00Z","timestamp":1743379200000},"content-version":"unspecified","delay-in-days":30,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2025,3,20]]},"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:p>A male patient in his 50s presented with severe bilateral wrist pain caused by scapholunate advanced collapse (SLAC). He did not wish to undergo a salvage treatment, and consecutively both affected scaphoids were replaced by 3D-modelled prostheses. 3 and 2 years postoperatively, the patient had significant pain reduction, good wrist function and grip strength. Final X-rays demonstrated no signs of dislocation of the implant or signs of periprosthetic arthritis. Studies have shown that once SLAC occurs, the treatment should consist of either a proximal row carpectomy or scaphoidectomy and four-corner fusion. In our case, despite collapse, replacement of the single affected bone by a 3D-modelled prosthesis led to good return of function.<\/jats:p>","DOI":"10.1136\/bcr-2024-264761","type":"journal-article","created":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T08:23:21Z","timestamp":1743409401000},"page":"e264761","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Treatment of scapholunate advanced collapse by 3D-modelled scaphoid prostheses"],"prefix":"10.1136","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0306-1565","authenticated-orcid":false,"given":"Marius A","family":"Kemler","sequence":"first","affiliation":[{"name":"Plastic Surgery, Martini Hospital, Groningen, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,3,31]]},"reference":[{"key":"2025082703014415000_18.3.e264761.1","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.jhsa.2024.01.011","article-title":"Four-Corner Fusion Versus Proximal Row Carpectomy for Scapholunate Advanced Collapse and Scaphoid Nonunion Advanced Collapse Wrist: A Systematic Review and Meta-Analysis","volume":"49","author":"Hones","year":"2024","journal-title":"J Hand Surg Am"},{"key":"2025082703014415000_18.3.e264761.2","doi-asserted-by":"crossref","DOI":"10.1136\/bcr-2023-257125","article-title":"Replacement of a destroyed scaphoimodelled prosthesis","volume":"16","author":"Kemler","year":"2023","journal-title":"BMJ Case Rep"},{"key":"2025082703014415000_18.3.e264761.3","unstructured":"Christensen A , Kircher R , Lippincott A . Qualification of electron beam melted (ebm) ti6ai4v-eli for orthopaedic applications. Medical Device Materials IV: Proceedings of the Materials and Processes for Medical Devices Conference.48\u201353."},{"key":"2025082703014415000_18.3.e264761.4","first-page":"40","article-title":"Metallurgy of additive manufacturing: Examples from electron beam melting","volume":"5","author":"Murr","year":"2015","journal-title":"Addit Manuf"},{"key":"2025082703014415000_18.3.e264761.5","unstructured":"Waldemar Link GmbH . Internal technical report: study of the influence of tinbn-coating on the ion release of cocrmo-alloys in SBF buffer simulator testing."},{"key":"2025082703014415000_18.3.e264761.6","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1007\/s00167-021-06775-6","article-title":"Systematic review and meta-analysis of ceramic coated implants in total knee arthroplasty. Comparable mid-term results to uncoated implants","volume":"31","author":"Banci","year":"2023","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2025082703014415000_18.3.e264761.7","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1016\/j.jhsa.2022.09.004","article-title":"Routinely-Collected Outcomes of Proximal Row Carpectomy","volume":"49","author":"Teunissen","year":"2024","journal-title":"J Hand Surg Am"},{"key":"2025082703014415000_18.3.e264761.8","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1186\/s12891-024-07527-6","article-title":"Patient reported and functional outcome measures after surgical salvage procedures for posttraumatic radiocarpal osteoarthritis - a systematic review","volume":"25","author":"Gruisen","year":"2024","journal-title":"BMC Musculoskelet Disord"},{"key":"2025082703014415000_18.3.e264761.9","doi-asserted-by":"crossref","unstructured":"Geuskens W , Verstreken A , Stroobants E , et al . Titanium patient-specific scaphoid replacement for unreconstructable nonunions: a case series study. J Hand Surg Eur Vol 2024. doi:10.1177\/17531934241276375","DOI":"10.1177\/17531934241276375"},{"key":"2025082703014415000_18.3.e264761.10","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s00402-024-05609-7","article-title":"Patient-specific scaphoid prosthesis: surgical technique","volume":"145","author":"Honigmann","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"key":"2025082703014415000_18.3.e264761.11","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(84)80223-3"},{"key":"2025082703014415000_18.3.e264761.12","unstructured":"Garcia-Elias M , Lluch AL . Wrist instabilities, misalignments, and dislocations. In: Wolfe S , Hotchkiss R , Pederson W , et al , eds. Green\u2019s operative hand surgery. 7th edn. Philadelphia, PA: Elsevier, 2016."}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2024-264761","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T10:01:56Z","timestamp":1756288916000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2024-264761"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":12,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,3,31]]},"published-print":{"date-parts":[[2025,3]]}},"alternative-id":["10.1136\/bcr-2024-264761"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2024-264761","relation":{},"ISSN":["1757-790X"],"issn-type":[{"value":"1757-790X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3]]}}}