{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T09:40:13Z","timestamp":1756287613547,"version":"3.44.0"},"reference-count":12,"publisher":"BMJ","issue":"6","license":[{"start":{"date-parts":[[2025,6,30]],"date-time":"2025-06-30T00:00:00Z","timestamp":1751241600000},"content-version":"unspecified","delay-in-days":29,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2025,6,18]]},"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:p>Acute prosthetic heart valve thrombosis (PHVT) is a severe complication affecting patients who have undergone heart valve replacement surgery. We present a case of acute recurrent PHVT associated with parasite-induced eosinophilia. A man in his early 50s with rheumatic heart disease underwent mechanical mitral valve replacement 5 years ago and received well-managed anticoagulation with regular follow-up visits. The patient developed a sudden onset of dyspnoea and was diagnosed with mechanical valve thrombosis, which was managed with thrombolysis. However, the valve became stuck again just a week after the initial episode while the patient was still in the hospital and was receiving anticoagulation within the target range. Concurrently, he experienced skin rashes and itching, prompting an investigation that revealed hypereosinophilia secondary to parasite infestation. The patient\u2019s valve functions well after thrombolysis and parasite infection treatment. The eosinophil counts were monitored to remain within the normal range.<\/jats:p>","DOI":"10.1136\/bcr-2025-265654","type":"journal-article","created":{"date-parts":[[2025,6,30]],"date-time":"2025-06-30T10:25:16Z","timestamp":1751279116000},"page":"e265654","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Successful management of recurrent thrombosis of prosthetic mitral valve induced by eosinophilia secondary to parasitic infection"],"prefix":"10.1136","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8655-3279","authenticated-orcid":false,"given":"Ly","family":"Nguyen Thi Minh","sequence":"first","affiliation":[{"name":"Cardiology, Hanoi Medical University, Hanoi, Viet Nam"},{"name":"Cardiovascular Center, Hanoi Medical University Hospital, Hanoi, Viet Nam"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4302-8612","authenticated-orcid":false,"given":"Hieu Lan","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Cardiovascular Center, Hanoi Medical University Hospital, Hanoi, Viet Nam"},{"name":"Hanoi Medical University Hospital, Hanoi, Viet Nam"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-6780-6394","authenticated-orcid":false,"given":"Lan Viet L","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Cardiology, Hanoi Medical University, Hanoi, Viet Nam"},{"name":"Hanoi Medical University Hospital, Hanoi, Viet Nam"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-5992-7913","authenticated-orcid":false,"given":"Ngoc Minh N","family":"Pham","sequence":"additional","affiliation":[{"name":"Hanoi Medical University Hospital, Hanoi, Viet Nam"},{"name":"Parasitology, Hanoi Medical University, Hanoi, Viet Nam"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-8715-3135","authenticated-orcid":false,"given":"Hoang","family":"Dang","sequence":"additional","affiliation":[{"name":"Hanoi Medical University Hospital, Hanoi, Viet Nam"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-0261-7401","authenticated-orcid":false,"given":"Lan Anh","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Nursing and Midwifery, Hanoi Medical University, Hanoi, Viet Nam"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4998-8510","authenticated-orcid":false,"given":"Hoa L","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Division of Epidemiology Department of Population and Quantitative Health Sciences, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert J","family":"Goldberg","sequence":"additional","affiliation":[{"name":"Population and Quantitative Health Sciences, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2025,6,30]]},"reference":[{"key":"2025082702032527000_18.6.e265654.1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2005.06.051"},{"key":"2025082702032527000_18.6.e265654.2","article-title":"A Unique Case of Cardiac Hypereosinophilia With Recurrent Valve Thrombosis After Mechanical Mitral Valve Replacement in the Setting of a Supratherapeutic International Normalized Ratio","volume":"14","author":"Ostojic","year":"2022","journal-title":"Cureus"},{"key":"2025082702032527000_18.6.e265654.3","doi-asserted-by":"publisher","DOI":"10.1172\/JCI34261"},{"key":"2025082702032527000_18.6.e265654.4","first-page":"721","article-title":"Obstructive prosthetic mitral valve thrombosis in idiopathic hypereosinophilic syndrome: a case report and review of the literature","volume":"15","author":"Hii","year":"2006","journal-title":"J Heart Valve Dis"},{"key":"2025082702032527000_18.6.e265654.5","doi-asserted-by":"crossref","DOI":"10.1136\/bcr-2017-221313","article-title":"Recurrent prosthetic heart valve thrombosis secondary to eosinophilia: a missed diagnosis","volume":"2017","author":"Rai","year":"2017","journal-title":"BMJ Case Rep"},{"key":"2025082702032527000_18.6.e265654.6","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.89.2.635"},{"key":"2025082702032527000_18.6.e265654.7","doi-asserted-by":"crossref","first-page":"e259","DOI":"10.1016\/j.athoracsur.2016.08.106","article-title":"Repeated Prosthetic Mitral Valve Thrombosis in Fluke Infection Induced Hypereosinophilic Syndrome","volume":"103","author":"Zhang","year":"2017","journal-title":"Ann Thorac Surg"},{"key":"2025082702032527000_18.6.e265654.8","doi-asserted-by":"publisher","DOI":"10.1177\/1076029609348314"},{"key":"2025082702032527000_18.6.e265654.9","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(15)60313-0"},{"key":"2025082702032527000_18.6.e265654.10","doi-asserted-by":"crossref","DOI":"10.1136\/bcr-2013-009917","article-title":"Successful thrombolytic treatment of prosthetic mitral valve thrombosis","volume":"2013","author":"Gazi","year":"2013","journal-title":"BMJ Case Rep"},{"key":"2025082702032527000_18.6.e265654.11","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/S0022-5223(95)70253-9","article-title":"Hypereosinophilic syndrome: cause of prosthetic valve obstruction","volume":"110","author":"Arsiwala","year":"1995","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2025082702032527000_18.6.e265654.12","doi-asserted-by":"crossref","first-page":"100","DOI":"10.4103\/apc.apc_93_21","article-title":"Repeated prosthetic heart valve thrombosis with idiopathic eosinophilia","volume":"15","author":"Choubey","year":"2022","journal-title":"Ann Pediatr Cardiol"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2025-265654","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T09:03:36Z","timestamp":1756285416000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2025-265654"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":12,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,6,30]]},"published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10.1136\/bcr-2025-265654"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2025-265654","relation":{},"ISSN":["1757-790X"],"issn-type":[{"type":"electronic","value":"1757-790X"}],"subject":[],"published":{"date-parts":[[2025,6]]}}}