{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T08:08:40Z","timestamp":1762848520028,"version":"build-2065373602"},"reference-count":16,"publisher":"BMJ","issue":"11","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2025,10,19]]},"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:p>Rupture of an angioplasty balloon is a known complication during endovascular procedures. We describe a case of a middle-aged female patient who was diagnosed with hepatic venous outflow tract obstruction. CT showed narrowing at the right hepatic vein ostium, for which the patient was planned for stenting followed by balloon angioplasty. We used a 14\u2009mm\u00d74\u2009cm balloon for angioplasty. During the procedure, there was a circumferential tear in the balloon, which became separated from its shaft and migrated distally into small branches of the vein. Various retrieval methods were employed; ultimately, a Dormia basket proved effective in retrieving the ruptured balloon in our case. A simple technique was helpful in managing this intraprocedural complication.<\/jats:p>","DOI":"10.1136\/bcr-2025-266752","type":"journal-article","created":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T08:05:26Z","timestamp":1762848326000},"page":"e266752","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Retrieval of ruptured balloon during hepatic venous balloon angioplasty using Dormia basket"],"prefix":"10.1136","volume":"18","author":[{"given":"Anushree","family":"Katiyar","sequence":"first","affiliation":[{"name":"Radiodiagnosis, All India Institute of Medical Sciences New Delhi, New Delhi, DL, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chandan J","family":"Das","sequence":"additional","affiliation":[{"name":"Radiodiagnosis, All India Institute of Medical Sciences New Delhi, New Delhi, DL, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Piyush","family":"Aggarwal","sequence":"additional","affiliation":[{"name":"Radiodiagnosis, All India Institute of Medical Sciences New Delhi, New Delhi, DL, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2025,11,10]]},"reference":[{"key":"2025111100052080000_18.11.e266752.1","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1177\/159101990501100205","article-title":"Percutaneous retrieval of intravascular broken catheter fragments. A novel technique using a balloon","volume":"11","author":"Gupta","year":"2005","journal-title":"Interv Neuroradiol"},{"key":"2025111100052080000_18.11.e266752.2","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1177\/1129729818785051","article-title":"Materials and techniques for percutaneous retrieval of intravascular foreign bodies","volume":"20","author":"Rossi","year":"2019","journal-title":"J Vasc Access"},{"key":"2025111100052080000_18.11.e266752.3","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.164.5.7717243"},{"key":"2025111100052080000_18.11.e266752.4","doi-asserted-by":"crossref","first-page":"101242","DOI":"10.1016\/j.jvscit.2023.101242","article-title":"Balloon rupture with eversion during innominate vein angioplasty requiring surgical retrieval","volume":"9","author":"Ali","year":"2023","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"2025111100052080000_18.11.e266752.5","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1177\/11297298211019891","article-title":"Entrapment of fractured balloon after angioplasty in an AV access using a covered stent","volume":"24","author":"Krishnamurthy","year":"2023","journal-title":"J Vasc Access"},{"key":"2025111100052080000_18.11.e266752.6","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/BF02734104","article-title":"Circumferential rupture of an angioplasty balloon with detachment from the shaft: case report","volume":"15","author":"Selby","year":"1992","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2025111100052080000_18.11.e266752.7","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.1253\/circj.CJ-12-1500","article-title":"Peri-stent abluminal hematoma and pin-hole balloon rupture during treatment of calcified drug-eluting stent in-stent restenosis","volume":"77","author":"Mart\u00edn","year":"2013","journal-title":"Circ J"},{"key":"2025111100052080000_18.11.e266752.8","doi-asserted-by":"crossref","first-page":"395","DOI":"10.2214\/ajr.135.2.395","article-title":"Circumferential tear of percutaneous transluminal angioplasty catheter balloon","volume":"135","author":"Yune","year":"1980","journal-title":"AJR Am J Roentgenol"},{"key":"2025111100052080000_18.11.e266752.9","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1007\/s12928-013-0221-9","article-title":"Retrieval of impacted broken balloon by balloon inflation in guiding catheter","volume":"29","author":"Mehta","year":"2014","journal-title":"Cardiovasc Interv Ther"},{"key":"2025111100052080000_18.11.e266752.10","first-page":"E45","article-title":"The clinical implications of balloon rupture during cardiovascular interventions","volume":"27","author":"Christopoulos","year":"2015","journal-title":"J Invasive Cardiol"},{"key":"2025111100052080000_18.11.e266752.11","doi-asserted-by":"crossref","first-page":"165","DOI":"10.4103\/ijves.ijves_126_24","article-title":"Unrecognized Rupture of Angioplasty Balloon: A Hidden Underlying Reason for the Delayed Occlusion of the Graft","volume":"12","author":"Ljatifi","year":"2025","journal-title":"Indian j vasc endovasc surg"},{"key":"2025111100052080000_18.11.e266752.12","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1177\/1129729819870634","article-title":"Retrieval strategy for ruptured balloon with circumferential tear during angioplasty for arteriovenous fistula in hemodialysis patients","volume":"21","author":"Murata","year":"2020","journal-title":"J Vasc Access"},{"key":"2025111100052080000_18.11.e266752.13","doi-asserted-by":"publisher","DOI":"10.1097\/01.RVI.0000208988.28121.AB"},{"key":"2025111100052080000_18.11.e266752.14","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/S1051-0443(95)71130-7","article-title":"Removal of a ruptured angioplasty balloon catheter with use of a nitinol goose neck snare","volume":"6","author":"Kirsch","year":"1995","journal-title":"J Vasc Interv Radiol"},{"key":"2025111100052080000_18.11.e266752.15","first-page":"OD06","article-title":"Catheter-Assisted Balloon-Supported Retrieval of a Broken Semi-Compliant Balloon from a Coronary Artery","volume":"11","author":"Kunwar","year":"2017","journal-title":"J Clin Diagn Res"},{"key":"2025111100052080000_18.11.e266752.16","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-005-0297-4"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2025-266752","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T08:05:29Z","timestamp":1762848329000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2025-266752"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11]]},"references-count":16,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11,10]]},"published-print":{"date-parts":[[2025,11]]}},"alternative-id":["10.1136\/bcr-2025-266752"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2025-266752","relation":{},"ISSN":["1757-790X"],"issn-type":[{"value":"1757-790X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11]]}}}