{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T02:39:13Z","timestamp":1763001553580,"version":"3.45.0"},"reference-count":21,"publisher":"BMJ","issue":"11","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2025,10,21]]},"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:p>We report an unusual case of haemodialysis catheter malposition into the pleural space causing haemothorax, despite ultrasound-guided insertion and X-ray confirmation. A patient with chronic kidney disease presented in respiratory failure due to pulmonary oedema and was scheduled for urgent haemodialysis. A haemodialysis catheter was inserted under ultrasound guidance, with apparent blood backflow, and postinsertion chest radiograph suggested proper placement. However, dialysis was interrupted multiple times due to persistently inadequate extracorporeal blood flow and visibly diluted blood in the circuit. Blood samples from the catheter revealed a significant drop in haemoglobin levels compared with baseline. Further imaging revealed catheter misplacement into the pleural cavity with haemothorax. This case underscores that even with standard placement verification techniques, rare malposition can occur. Clinicians should maintain a high index of suspicion and pursue further evaluation when unexplained flow or clinical abnormalities arise during dialysis.<\/jats:p>","DOI":"10.1136\/bcr-2025-267403","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T02:35:21Z","timestamp":1763001321000},"page":"e267403","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Pleural malpositioning of a haemodialysis catheter causing haemothorax despite the use of ultrasound guided placement and chest radiograph confirmation."],"prefix":"10.1136","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6971-1236","authenticated-orcid":false,"given":"Venkat Raman","family":"Kola","sequence":"first","affiliation":[{"name":"Critical Care Medicine, Yashoda Group of Hospitals, Hyderabad, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sowmya","family":"Koneru","sequence":"additional","affiliation":[{"name":"Critical Care Medicine, Yashoda Group of Hospitals, Hyderabad, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Madhava Reddy","family":"Devireddy","sequence":"additional","affiliation":[{"name":"Critical Care Medicine, Yashoda Group of Hospitals, Hyderabad, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ravi Shankar","family":"Vattikuti","sequence":"additional","affiliation":[{"name":"Critical Care Medicine, Yashoda Group of Hospitals, Hyderabad, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2025,11,12]]},"reference":[{"key":"2025111218351436000_18.11.e267403.1","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0b013e3182407cd8"},{"key":"2025111218351436000_18.11.e267403.2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-012-2597-x"},{"key":"2025111218351436000_18.11.e267403.3","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1007\/s00134-015-3728-y","article-title":"What\u2019s really new in the field of vascular access? Towards a global use of ultrasound","volume":"41","author":"Biasucci","year":"2015","journal-title":"Intensive Care Med"},{"key":"2025111218351436000_18.11.e267403.4","first-page":"473","article-title":"EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part VI - Ultrasound-Guided Vascular Interventions","volume":"37","author":"Jenssen","year":"2016","journal-title":"Ultraschall Med"},{"key":"2025111218351436000_18.11.e267403.5","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2011.07.025"},{"key":"2025111218351436000_18.11.e267403.6","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.327.7411.361"},{"key":"2025111218351436000_18.11.e267403.7","doi-asserted-by":"publisher","DOI":"10.7863\/ultra.34.7.1301"},{"key":"2025111218351436000_18.11.e267403.8","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1097\/EJA.0000000000000042","article-title":"Ultrasound confirmation of central venous catheter position via a right supraclavicular fossa view using a microconvex probe: an observational pilot study","volume":"32","author":"Kim","year":"2015","journal-title":"Eur J Anaesthesiol"},{"key":"2025111218351436000_18.11.e267403.9","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e3181c0328f"},{"key":"2025111218351436000_18.11.e267403.10","doi-asserted-by":"crossref","first-page":"1192","DOI":"10.1097\/CCM.0000000000002451","article-title":"Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax","volume":"45","author":"Amir","year":"2017","journal-title":"Crit Care Med"},{"key":"2025111218351436000_18.11.e267403.11","first-page":"212","article-title":"The use of ultrasound for placement of intravenous catheters","volume":"75","author":"Aponte","year":"2007","journal-title":"AANA J"},{"key":"2025111218351436000_18.11.e267403.12","doi-asserted-by":"publisher","DOI":"10.1378\/chest.11-2054"},{"key":"2025111218351436000_18.11.e267403.13","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-005-2791-1"},{"key":"2025111218351436000_18.11.e267403.14","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.164.3.2009042"},{"key":"2025111218351436000_18.11.e267403.15","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1177\/0310057X0703500419","article-title":"Investigation of a new echogenic needle for use with ultrasound peripheral nerve blocks","volume":"35","author":"Deam","year":"2007","journal-title":"Anaesth Intensive Care"},{"key":"2025111218351436000_18.11.e267403.16","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.1007\/s00134-013-3097-3","article-title":"Guidewire localization by transthoracic echocardiography during central venous catheter insertion: a periprocedural method to evaluate catheter placement","volume":"39","author":"Bedel","year":"2013","journal-title":"Intensive Care Med"},{"key":"2025111218351436000_18.11.e267403.17","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.jvsv.2019.06.020","article-title":"Prevention and treatment of dilator injuries during central venous catheter placement","volume":"7","author":"Collier","year":"2019","journal-title":"J Vasc Surg Venous Lymphat Disord"},{"key":"2025111218351436000_18.11.e267403.18","doi-asserted-by":"crossref","DOI":"10.1056\/NEJMvcm0810156","article-title":"Videos in clinical medicine. Ultrasound-guided internal jugular vein cannulation","volume":"362","author":"Ortega","year":"2010","journal-title":"N Engl J Med"},{"key":"2025111218351436000_18.11.e267403.19","doi-asserted-by":"publisher","DOI":"10.1097\/AAP.0b013e31820d4349"},{"key":"2025111218351436000_18.11.e267403.20","doi-asserted-by":"crossref","DOI":"10.1056\/NEJMvcm1005951","article-title":"Videos in clinical medicine. Ultrasound-guided peripheral i.v. placement","volume":"366","author":"Joing","year":"2012","journal-title":"N Engl J Med"},{"key":"2025111218351436000_18.11.e267403.21","doi-asserted-by":"crossref","first-page":"658","DOI":"10.5811\/westjem.2015.7.26248","article-title":"Central Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction","volume":"16","author":"Roldan","year":"2015","journal-title":"West J Emerg Med"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2025-267403","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T02:35:24Z","timestamp":1763001324000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2025-267403"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11]]},"references-count":21,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11,12]]},"published-print":{"date-parts":[[2025,11]]}},"alternative-id":["10.1136\/bcr-2025-267403"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2025-267403","relation":{},"ISSN":["1757-790X"],"issn-type":[{"value":"1757-790X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11]]}}}