{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T15:08:53Z","timestamp":1772118533716,"version":"3.50.1"},"reference-count":15,"publisher":"BMJ","issue":"2","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Case Rep"],"accepted":{"date-parts":[[2026,1,17]]},"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:p>\n                    Pulse oximetry guides the management of respiratory conditions through non-invasively monitoring arterial oxygen saturation. Unstable haemoglobin variants may produce inaccurate readings. We describe a man in his 60s with chronic obstructive pulmonary disease admitted to hospital with a lower respiratory tract infection and pulmonary emboli. His pulse oximetry saturation was 88% on 3\u2009L nasal cannula. However, an arterial blood gas (ABG) showed his oxygen saturation (sO\n                    <jats:sub>2)<\/jats:sub>\n                    at 96.7% and his partial pressure of carbon dioxide raised to 6.0\u2009kPa (45.0\u2009mm Hg). His oxygen was removed, and his pulse oximetry reading dropped to 79%\u201380%. A simultaneous ABG showed an sO\n                    <jats:sub>2<\/jats:sub>\n                    of 91.3%, demonstrating \u224810% saturation gap in oxygen saturation between the pulse oximetry and ABG readings. Subsequent genetic testing confirmed haemoglobin K\u00f6ln. We recommend performing an ABG and investigating for unstable haemoglobinopathies when the pulse oximetry and arterial oxygen readings are discordant. This is important for patients with respiratory diseases, as over-oxygenation can lead to decompensated type 2 respiratory failure.\n                  <\/jats:p>","DOI":"10.1136\/bcr-2025-269010","type":"journal-article","created":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T14:00:18Z","timestamp":1772114418000},"page":"e269010","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Exploring haemoglobin K\u00f6ln: a rare cause of pulse oximetry and arterial oxygen saturation discrepancy"],"prefix":"10.1136","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9310-4607","authenticated-orcid":false,"given":"Leshanth","family":"Uthayanan","sequence":"first","affiliation":[{"name":"Respiratory Medicine, George Eliot Hospital NHS Trust, Nuneaton, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rida","family":"Suleman","sequence":"additional","affiliation":[{"name":"Respiratory Medicine, George Eliot Hospital NHS Trust, Nuneaton, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luke","family":"Green","sequence":"additional","affiliation":[{"name":"Respiratory Medicine, George Eliot Hospital NHS Trust, Nuneaton, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alveena","family":"Imran","sequence":"additional","affiliation":[{"name":"Respiratory Medicine, George Eliot Hospital NHS Trust, Nuneaton, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Calvin","family":"Luk","sequence":"additional","affiliation":[{"name":"Haematology, George Eliot Hospital NHS Trust, Nuneaton, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward Fairbairn","family":"Nash","sequence":"additional","affiliation":[{"name":"Respiratory Medicine, George Eliot Hospital NHS Trust, Nuneaton, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2026,2,26]]},"reference":[{"key":"2026022606001177000_19.2.e269010.1","first-page":"541","article-title":"Pulse oximetry: a review of the theory, accuracy, and clinical applications","volume":"74","author":"Bowes","year":"1989","journal-title":"Obstet Gynecol"},{"key":"2026022606001177000_19.2.e269010.2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1096-8652(199811)59:3<181::AID-AJH1>3.0.CO;2-I"},{"key":"2026022606001177000_19.2.e269010.3","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.04435"},{"key":"2026022606001177000_19.2.e269010.4","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-015-0984-8"},{"key":"2026022606001177000_19.2.e269010.5","doi-asserted-by":"crossref","DOI":"10.1016\/j.eclinm.2022.101428","article-title":"Impact of ethnicity on the accuracy of measurements of oxygen saturations: A retrospective observational cohort study","volume":"48","author":"Bangash","year":"2022","journal-title":"EClinicalMedicine"},{"key":"2026022606001177000_19.2.e269010.6","doi-asserted-by":"publisher","DOI":"10.1007\/BF03010939"},{"key":"2026022606001177000_19.2.e269010.7","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1002\/ajh.22074","article-title":"Erratum to: Unexpectedly low pulse oximetry measurements associated with variant hemoglobins: A systematic review","volume":"86","author":"Verhovsek","year":"2011","journal-title":"American J Hematol"},{"key":"2026022606001177000_19.2.e269010.8","doi-asserted-by":"crossref","first-page":"1368068","DOI":"10.3389\/fmed.2024.1368068","article-title":"Unmasking hemoglobin K\u00f6ln: a rare cause of discrepancies between pulse oximetry and arterial oxygen saturation\u2014a case report","volume":"11","author":"Alshurafa","year":"2024","journal-title":"Front Med"},{"key":"2026022606001177000_19.2.e269010.9","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1213\/XAA.0000000000000563","article-title":"Low SpO2 With Normal SaO2 During General Anesthesia","volume":"9","author":"Brugger","year":"2017","journal-title":"A A Case Rep"},{"key":"2026022606001177000_19.2.e269010.10","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1097\/00000542-199402000-00030","article-title":"An unexpected finding with pulse oximetry in a patient with hemoglobin K\u00f6ln","volume":"80","author":"Gottschalk","year":"1994","journal-title":"Anesthesiology"},{"key":"2026022606001177000_19.2.e269010.11","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1097\/00000542-199402000-00029","article-title":"Unexpectedly low pulse oximeter readings in a boy with unstable hemoglobin K\u00f6ln","volume":"80","author":"Katoh","year":"1994","journal-title":"Anesthesiology"},{"key":"2026022606001177000_19.2.e269010.12","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1016\/S1701-2163(16)32971-1","article-title":"Hemoglobin k\u00f6ln and pregnancy","volume":"30","author":"Cheung","year":"2008","journal-title":"J Obstet Gynaecol Can"},{"key":"2026022606001177000_19.2.e269010.13","doi-asserted-by":"crossref","DOI":"10.3390\/jcm13020458","article-title":"High-Oxygen-Affinity Hemoglobins-Case Series and Review of the Literature","volume":"13","author":"Komninaka","year":"2024","journal-title":"J Clin Med"},{"key":"2026022606001177000_19.2.e269010.14","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1182\/blood.V39.3.398.398","article-title":"Oxygen affinity in hemoglobin K\u00f6ln disease","volume":"39","author":"De Furia","year":"1972","journal-title":"Blood"},{"key":"2026022606001177000_19.2.e269010.15","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1182\/blood.V38.6.715.715","article-title":"Hemoglobin K\u00f6ln disease occurring as a fresh mutation: erythrocyte metabolism and survival","volume":"38","author":"Miller","year":"1971","journal-title":"Blood"}],"container-title":["BMJ Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bcr-2025-269010","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T14:00:22Z","timestamp":1772114422000},"score":1,"resource":{"primary":{"URL":"https:\/\/casereports.bmj.com\/lookup\/doi\/10.1136\/bcr-2025-269010"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":15,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,2,26]]},"published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1136\/bcr-2025-269010"],"URL":"https:\/\/doi.org\/10.1136\/bcr-2025-269010","relation":{},"ISSN":["1757-790X"],"issn-type":[{"value":"1757-790X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2]]}}}