{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T09:41:09Z","timestamp":1778492469555,"version":"3.51.4"},"reference-count":11,"publisher":"BMJ","issue":"11","license":[{"start":{"date-parts":[[2025,6,30]],"date-time":"2025-06-30T00:00:00Z","timestamp":1751241600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"accepted":{"date-parts":[[2025,6,24]]},"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:p>This study aims to assess the accuracy of CT imaging in estimating intraocular foreign body (IOFB) size by comparing pre-operative radiological measurements with post-surgical dimensions. A retrospective review of 12 cases over 9 years at a UK tertiary centre. IOFB size on CT imaging was compared with post-surgical measurements. Soft tissue window CT overestimated IOFB size (p=0.025). Bone window CT was more accurate but still varied, with one-third differing by&gt;50%\u2009to definitive size. We conclude that caution is needed in CT-based IOFB size estimation. Plain radiographs may provide additional accuracy.<\/jats:p>","DOI":"10.1136\/bjo-2025-327245","type":"journal-article","created":{"date-parts":[[2025,6,30]],"date-time":"2025-06-30T13:20:21Z","timestamp":1751289621000},"page":"1295-1297","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["An evaluation of approaches to imaging for the pre-surgical assessment of intraocular foreign body size"],"prefix":"10.1136","volume":"109","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-8457-2104","authenticated-orcid":false,"given":"Kujani","family":"Wanniarachchi","sequence":"first","affiliation":[{"name":"Vitreoretinal Research Group, University of Cambridge John van Geest Centre for Brain Repair, Cambridge, England, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hrishikesh","family":"Kaza","sequence":"additional","affiliation":[{"name":"Vitreoretinal Research Group, University of Cambridge John van Geest Centre for Brain Repair, Cambridge, England, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antoine","family":"Safi","sequence":"additional","affiliation":[{"name":"Whipps Cross University Hospital NHS Trust, London, England, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tarini","family":"Ratneswaren","sequence":"additional","affiliation":[{"name":"Interventional neuroradiology department, National Hospital for Neurology and Neurosurgery, London, England, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arabella","family":"Poulson","sequence":"additional","affiliation":[{"name":"Vitreoretinal Research Group, University of Cambridge John van Geest Centre for Brain Repair, Cambridge, England, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0042-8659","authenticated-orcid":false,"given":"Martin P","family":"Snead","sequence":"additional","affiliation":[{"name":"Vitreoretinal Research Group, University of Cambridge John van Geest Centre for Brain Repair, Cambridge, England, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2025,6,30]]},"reference":[{"key":"2026012223102360000_109.11.1295.1","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1038\/sj.eye.6702868","article-title":"Surveillance of intraocular foreign bodies in the UK","volume":"22","author":"Imrie","year":"2008","journal-title":"Eye (Lond)"},{"key":"2026012223102360000_109.11.1295.2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2016.03.005"},{"key":"2026012223102360000_109.11.1295.3","doi-asserted-by":"publisher","DOI":"10.1080\/08820538.2019.1674894"},{"key":"2026012223102360000_109.11.1295.4","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2003.815073"},{"key":"2026012223102360000_109.11.1295.5","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0000000000000271"},{"key":"2026012223102360000_109.11.1295.6","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0000000000002099"},{"key":"2026012223102360000_109.11.1295.7","doi-asserted-by":"publisher","DOI":"10.1177\/112067210901900528"},{"key":"2026012223102360000_109.11.1295.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcma.2014.05.006"},{"key":"2026012223102360000_109.11.1295.9","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-41105-5"},{"key":"2026012223102360000_109.11.1295.10","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/68589458"},{"key":"2026012223102360000_109.11.1295.11","doi-asserted-by":"crossref","first-page":"11","DOI":"10.18869\/acadpub.3dj.5.1.11","article-title":"Evaluation of Image Magnification in Digital Panoramic Radiography","volume":"5","author":"Paknahad","year":"2016","journal-title":"3dj"}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjo-2025-327245","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T07:10:41Z","timestamp":1769152241000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjo-2025-327245"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,30]]},"references-count":11,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,10,23]]},"published-print":{"date-parts":[[2025,11]]}},"alternative-id":["10.1136\/bjo-2025-327245"],"URL":"https:\/\/doi.org\/10.1136\/bjo-2025-327245","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,30]]}}}