{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T02:33:32Z","timestamp":1769135612265,"version":"3.49.0"},"reference-count":32,"publisher":"BMJ","issue":"2","funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["23H03063 (TY)"],"award-info":[{"award-number":["23H03063 (TY)"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"accepted":{"date-parts":[[2025,8,11]]},"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>The purpose of this study is to investigate the accuracy of intraocular lens (IOL) power calculation after penetrating keratoplasty (PK) or deep anterior lamellar keratoplasty (DALK) and to identify the causes of predictive errors (PEs) in relation to the subjective keratometric (K) value (SK) in eyes with corneal multifocality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This retrospective study included 74 eyes that underwent cataract surgery after PK or DALK. PEs were compared between SRK\/T, Haigis, Barrett Universal II (BUII) and Kane formulas. In 27 eyes with postoperative anterior segment optical coherence tomography (AS-OCT) data, SKs were calculated based on postoperative refraction, IOL position, IOL power and axial length using Zemax. This was compared with K values obtained using AS-OCT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Mean absolute PE was 1.50\u00b11.60 dioptre in SRK\/T, 1.96\u00b11.80 in Haigis, 1.84\u00b11.71 in BUII and 1.83\u00b11.86 in Kane. SK was significantly correlated with true K (TK) (r=0.86, p&lt;0.001). The difference between SK and TK showed a significant correlation with PE in SRK\/T (r=0.53, p=0.001). The PE in SRK\/T was modelled as a function of the change in preoperative and postoperative K values as well as the difference between TK and SK, with significant improvement in the PE after factoring in these parameters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Multifocal corneas, such as those after PK or DALK, may have SK values that differ significantly from K values obtained from AS-OCT. Therefore, traditional IOL formulas that use standard K values may lead to a refractive surprise after cataract surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bjo-2025-327868","type":"journal-article","created":{"date-parts":[[2025,8,25]],"date-time":"2025-08-25T01:30:24Z","timestamp":1756085424000},"page":"133-138","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Corneal multifocality after penetrating keratoplasty or deep anterior lamellar keratoplasty is associated with intraocular lens power calculation error"],"prefix":"10.1136","volume":"110","author":[{"given":"Yuki","family":"Shiraishi","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6726-4508","authenticated-orcid":false,"given":"Enchi K","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Harvard University, Boston, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7980-7741","authenticated-orcid":false,"given":"Yukari","family":"Yagi-Yaguchi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuma","family":"Kayama","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuki","family":"Kusano","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6361-3600","authenticated-orcid":false,"given":"Daisuke","family":"Tomida","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4171-0781","authenticated-orcid":false,"given":"So","family":"Goto","sequence":"additional","affiliation":[{"name":"Ophthalmology, Osaka University, Suita, Osaka Prefecture, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2800-126X","authenticated-orcid":false,"given":"Tjundewo","family":"Lawu","sequence":"additional","affiliation":[{"name":"Design and Consult, VO, Toda, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4429-2004","authenticated-orcid":false,"given":"Vishal","family":"Jhanji","sequence":"additional","affiliation":[{"name":"University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2546-2813","authenticated-orcid":false,"given":"Takefumi","family":"Yamaguchi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2025,8,24]]},"reference":[{"key":"2026012202151217000_110.2.133.1","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.ajo.2025.02.035","article-title":"Comparative Analysis of Eighteen IOL Power Calculation Formulas Using a Modified Formula Performance Index Across Diverse Biometric Parameters","volume":"273","author":"Ma","year":"2025","journal-title":"Am J Ophthalmol"},{"key":"2026012202151217000_110.2.133.2","doi-asserted-by":"crossref","first-page":"1893","DOI":"10.1007\/s40123-024-00954-7","article-title":"Accuracy of 20 Intraocular Lens Power Calculation Formulas in Medium-Long Eyes","volume":"13","author":"Stopyra","year":"2024","journal-title":"Ophthalmol Ther"},{"key":"2026012202151217000_110.2.133.3","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80917-0"},{"key":"2026012202151217000_110.2.133.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.08.027"},{"key":"2026012202151217000_110.2.133.5","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80140-X"},{"key":"2026012202151217000_110.2.133.6","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1016\/j.jcrs.2011.05.042","article-title":"Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm","volume":"37","author":"Wang","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"2026012202151217000_110.2.133.7","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2007.00879.x"},{"key":"2026012202151217000_110.2.133.8","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.ajo.2013.04.035","article-title":"Scheimpflug corneal power measurements for intraocular lens power calculation in cataract surgery","volume":"156","author":"Saad","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"2026012202151217000_110.2.133.9","doi-asserted-by":"crossref","DOI":"10.1186\/s12886-019-1036-y","article-title":"Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross-sectional study","volume":"19","author":"An","year":"2019","journal-title":"BMC Ophthalmol"},{"key":"2026012202151217000_110.2.133.10","doi-asserted-by":"crossref","first-page":"2474","DOI":"10.1016\/j.ophtha.2016.09.005","article-title":"Prediction of Postoperative Intraocular Lens Position with Angle-to-Angle Depth Using Anterior Segment Optical Coherence Tomography","volume":"123","author":"Goto","year":"2016","journal-title":"Ophthalmology"},{"key":"2026012202151217000_110.2.133.11","doi-asserted-by":"crossref","first-page":"e121","DOI":"10.1016\/j.ophtha.2020.06.054","article-title":"Intraocular Lens Power Calculations in Eyes with Previous Corneal Refractive Surgery","volume":"128","author":"Wang","year":"2021","journal-title":"Ophthalmology"},{"key":"2026012202151217000_110.2.133.12","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1038\/s41598-018-20040-w","article-title":"Predictability of Intraocular Lens Power Calculation for Cataract with Keratoconus: A Multicenter Study","volume":"8","author":"Kamiya","year":"2018","journal-title":"Sci Rep"},{"key":"2026012202151217000_110.2.133.13","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1097\/00003226-200108000-00005","article-title":"Intraocular lens implantation after penetrating keratoplasty","volume":"20","author":"Hsiao","year":"2001","journal-title":"Cornea"},{"key":"2026012202151217000_110.2.133.14","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1111\/ceo.14026","article-title":"Accuracy of intraocular lens power calculation for cataract surgery after deep anterior lamellar keratoplasty","volume":"50","author":"Pellegrini","year":"2022","journal-title":"Clin Exp Ophthalmol"},{"key":"2026012202151217000_110.2.133.15","first-page":"2882","article-title":"Apparent accommodation and corneal wavefront aberration in pseudophakic eyes","volume":"43","author":"Oshika","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2026012202151217000_110.2.133.16","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90259-2"},{"key":"2026012202151217000_110.2.133.17","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-7647"},{"key":"2026012202151217000_110.2.133.18","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-307427"},{"key":"2026012202151217000_110.2.133.19","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1186\/s40662-021-00265-z","article-title":"Machine learning adaptation of intraocular lens power calculation for a patient group","volume":"8","author":"Mori","year":"2021","journal-title":"Eye and Vis"},{"key":"2026012202151217000_110.2.133.20","doi-asserted-by":"crossref","DOI":"10.1167\/tvst.10.4.27","article-title":"Determining the Theoretical Effective Lens Position of Thick Intraocular Lenses for Machine Learning-Based IOL Power Calculation and Simulation","volume":"10","author":"Gatinel","year":"2021","journal-title":"Transl Vis Sci Technol"},{"key":"2026012202151217000_110.2.133.21","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.ajo.2023.03.037","article-title":"Intraocular Lens Power Calculations in Keratoconus Eyes Comparing Keratometry, Total Keratometry, and Newer Formulae","volume":"253","author":"Heath","year":"2023","journal-title":"Am J Ophthalmol"},{"key":"2026012202151217000_110.2.133.22","first-page":"949","article-title":"Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus","volume":"12","author":"Krysik","year":"2019","journal-title":"Int J Ophthalmol"},{"key":"2026012202151217000_110.2.133.23","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000230496.22520.93"},{"key":"2026012202151217000_110.2.133.24","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1016\/j.jcrs.2018.01.024","article-title":"Cataract surgery after deep anterior lamellar keratoplasty","volume":"44","author":"Den","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"2026012202151217000_110.2.133.25","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1097\/00003226-200304000-00010","article-title":"Corneal opacity and cataract: triple procedure versus secondary approach","volume":"22","author":"Shimmura","year":"2003","journal-title":"Cornea"},{"key":"2026012202151217000_110.2.133.26","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.ajo.2016.12.014","article-title":"Corneal Higher-Order Aberrations in Infectious Keratitis","volume":"175","author":"Shimizu","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"2026012202151217000_110.2.133.27","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.jtos.2019.07.006","article-title":"Corneal higher-order aberrations in Stevens-Johnson syndrome and toxic epidermal necrolysis","volume":"17","author":"Ibrahim","year":"2019","journal-title":"Ocul Surf"},{"key":"2026012202151217000_110.2.133.28","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1007\/s10384-020-00759-8","article-title":"Corneal higher-order aberrations in phlyctenular keratitis","volume":"64","author":"Katayama","year":"2020","journal-title":"Jpn J Ophthalmol"},{"key":"2026012202151217000_110.2.133.29","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1038\/s41598-023-28145-7","article-title":"Changes in corneal higher-order aberrations during treatment for infectious keratitis","volume":"13","author":"Matsumura","year":"2023","journal-title":"Sci Rep"},{"key":"2026012202151217000_110.2.133.30","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.01.009"},{"key":"2026012202151217000_110.2.133.31","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.01.008"},{"key":"2026012202151217000_110.2.133.32","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2013.08.017"}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjo-2025-327868","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T10:15:34Z","timestamp":1769076934000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjo-2025-327868"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,24]]},"references-count":32,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,1,22]]},"published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1136\/bjo-2025-327868"],"URL":"https:\/\/doi.org\/10.1136\/bjo-2025-327868","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,24]]}}}