{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T16:01:28Z","timestamp":1767888088695,"version":"3.49.0"},"reference-count":42,"publisher":"BMJ","issue":"10","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"published-print":{"date-parts":[[2017,10]]},"DOI":"10.1136\/bjophthalmol-2016-308710","type":"journal-article","created":{"date-parts":[[2017,3,8]],"date-time":"2017-03-08T02:00:24Z","timestamp":1488938424000},"page":"1323-1328","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":18,"title":["Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep"],"prefix":"10.1136","volume":"101","clinical-trial-number":[{"clinical-trial-number":"nct01351779","registry":"10.18810\/clinical-trials-gov"}],"author":[{"given":"Laura","family":"Beltran-Agull\u00f3","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yvonne M","family":"Buys","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Farzana","family":"Jahan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Colin M","family":"Shapiro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John G","family":"Flanagan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Graham E","family":"Trope","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2017,3,7]]},"reference":[{"key":"key-10.1136\/bjophthalmol-2016-308710-1","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1001\/archopht.124.2.165","article-title":"Increase of peak intraocular pressure during sleep in reproduced diurnal changes by posture","volume":"124","author":"Hara","year":"2006","journal-title":"Arch Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-2","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/j.ajo.2004.09.062","article-title":"Correlation between office and peak nocturnal intraocular pressures in healthy subjects and glaucoma patients","volume":"139","author":"Mosaed","year":"2005","journal-title":"Am J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-3","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/S0161-6420(00)00411-5","article-title":"Twenty-four-hour time course of intraocular pressure in healthy and glaucomatous Africans: relation to sleep patterns","volume":"108","author":"No\u00ebl","year":"2001","journal-title":"Ophthalmology"},{"key":"key-10.1136\/bjophthalmol-2016-308710-4","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1001\/archophthalmol.2011.72","article-title":"Risk factors for visual field progression in treated glaucoma","volume":"129","author":"De Moraes","year":"2011","journal-title":"Arch Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-5","first-page":"204","article-title":"The influence of position on intraocular pressure","volume":"12","author":"Anderson","year":"1973","journal-title":"Invest Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-6","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/ICU.0b013e32831eef4f","article-title":"Intraocular pressure measurements throughout the 24\u2005h","volume":"20","author":"Bagga","year":"2009","journal-title":"Curr Opin Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-7","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1136\/bjo.60.10.687","article-title":"Rapid pneumatic and Mackey-Marg applanation tonometry to evaluate the postural effect on intraocular pressure","volume":"60","author":"Jain","year":"1976","journal-title":"Br J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-8","doi-asserted-by":"crossref","first-page":"1586","DOI":"10.1167\/iovs.02-0666","article-title":"Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes","volume":"44","author":"Liu","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"key-10.1136\/bjophthalmol-2016-308710-9","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1167\/iovs.11-8763","article-title":"Effects of aging on 24-hour intraocular pressure measurements in sitting and supine body positions","volume":"53","author":"Mansouri","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"key-10.1136\/bjophthalmol-2016-308710-10","doi-asserted-by":"crossref","first-page":"8050","DOI":"10.1167\/iovs.12-10569","article-title":"Analysis of continuous 24-h intraocular pressure patterns in glaucoma","volume":"53","author":"Mansouri","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"key-10.1136\/bjophthalmol-2016-308710-11","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1136\/bjo.68.6.389","article-title":"Postural change of IOP in normal persons and in patients with primary wide open-angle glaucoma and low-tension glaucoma","volume":"68","author":"Tsukahara","year":"1984","journal-title":"Br J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-12","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1136\/bjo.60.2.111","article-title":"Postural change and intraocular pressure in glaucomatous eyes","volume":"60","author":"W\u00fcthrich","year":"1976","journal-title":"Br J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-13","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1016\/j.ophtha.2009.11.015","article-title":"Effect of sleeping in a head-up position on intraocular pressure in patients with glaucoma","volume":"117","author":"Buys","year":"2010","journal-title":"Ophthalmology"},{"key":"key-10.1136\/bjophthalmol-2016-308710-14","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/BF00414618","article-title":"The vascular basis of the positional influence on the intraocular pressure","volume":"206","author":"Krieglstein","year":"1978","journal-title":"Albrecht Von Graefes Arch Klin Exp Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-15","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1136\/bjo.2010.192922","article-title":"Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma","volume":"95","author":"Mansouri","year":"2011","journal-title":"Br J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-16","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1097\/IJG.0b013e31829e5635","article-title":"Evaluation of continuous 24-hour intraocular pressure monitoring for assessment of prostaglandin-induced pressure reduction in glaucoma","volume":"23","author":"Holl\u00f3","year":"2014","journal-title":"J Glaucoma"},{"key":"key-10.1136\/bjophthalmol-2016-308710-17","first-page":"211","article-title":"Overnight swelling of the living human cornea","volume":"51","author":"Mertz","year":"1980","journal-title":"J Am Optom Assoc"},{"key":"key-10.1136\/bjophthalmol-2016-308710-18","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1097\/00003226-200304000-00004","article-title":"Diurnal variation of corneal sensitivity and thickness","volume":"22","author":"du Toit","year":"2003","journal-title":"Cornea"},{"key":"key-10.1136\/bjophthalmol-2016-308710-19","doi-asserted-by":"crossref","first-page":"4742","DOI":"10.1167\/iovs.03-0239","article-title":"Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction","volume":"44","author":"Wang","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"key-10.1136\/bjophthalmol-2016-308710-20","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/01.icl.0000242166.09513.aa","article-title":"The impact of silicone hydrogel materials on overnight corneal swelling","volume":"33","author":"Steffen","year":"2007","journal-title":"Eye Contact Lens"},{"key":"key-10.1136\/bjophthalmol-2016-308710-21","doi-asserted-by":"crossref","first-page":"e534","DOI":"10.1111\/j.1755-3768.2012.02495.x","article-title":"Corneal thickness after overnight wear of an intraocular pressure fluctuation contact lens sensor","volume":"90","author":"Freiberg","year":"2012","journal-title":"Acta Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-22","doi-asserted-by":"crossref","first-page":"e119","DOI":"10.1111\/aos.12241","article-title":"Effect of overnight wear of the Triggerfish(\u00ae) sensor on corneal thickness measured by Visante(\u00ae) anterior segment optical coherence tomography","volume":"92","author":"Hubanova","year":"2014","journal-title":"Acta Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-23","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1097\/IJG.0b013e318241b874","article-title":"Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens","volume":"22","author":"Lorenz","year":"2013","journal-title":"J Glaucoma"},{"key":"key-10.1136\/bjophthalmol-2016-308710-24","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1111\/j.1755-3768.2008.01404.x","article-title":"Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes","volume":"87","author":"Leonardi","year":"2009","journal-title":"Acta Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-25","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/S0002-9394(14)73143-5","article-title":"24-hour (nyctohemeral) and sleep-related variations of intraocular pressure in healthy White individuals","volume":"117","author":"Buguet","year":"1994","journal-title":"Am J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-26","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.smrv.2014.03.003","article-title":"Hypertension and sleep: overview of a tight relationship","volume":"18","author":"Pepin","year":"2014","journal-title":"Sleep Med Rev"},{"key":"key-10.1136\/bjophthalmol-2016-308710-27","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1016\/S0002-9394(03)00709-8","article-title":"The prevalence of glaucoma in patients with sleep apnea syndrome: same as in the general population","volume":"136","author":"Geyer","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-28","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1038\/sj.eye.6702846","article-title":"Prevalence of glaucoma in patients with obstructive sleep apnoea--a cross-sectional case-series","volume":"22","author":"Bendel","year":"2008","journal-title":"Eye (Lond)"},{"key":"key-10.1136\/bjophthalmol-2016-308710-29","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1016\/S0161-6420(99)00525-4","article-title":"High prevalence of glaucoma in patients with sleep apnea syndrome","volume":"106","author":"Mojon","year":"1999","journal-title":"Ophthalmology"},{"key":"key-10.1136\/bjophthalmol-2016-308710-30","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1159\/000059625","article-title":"Normal-tension glaucoma is associated with sleep apnea syndrome","volume":"216","author":"Mojon","year":"2002","journal-title":"Ophthalmologica"},{"key":"key-10.1136\/bjophthalmol-2016-308710-31","doi-asserted-by":"crossref","first-page":"e81","DOI":"10.1097\/IJG.0b013e31829da19f","article-title":"Floppy eyelid syndrome as an indicator of the presence of glaucoma in patients with obstructive sleep apnea","volume":"23","author":"Muniesa","year":"2014","journal-title":"J Glaucoma"},{"key":"key-10.1136\/bjophthalmol-2016-308710-32","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1097\/01.ijg.0000243472.51461.24","article-title":"Prevalence of normal tension glaucoma in obstructive sleep apnea syndrome patients","volume":"16","author":"Sergi","year":"2007","journal-title":"J Glaucoma"},{"key":"key-10.1136\/bjophthalmol-2016-308710-33","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1016\/j.ophtha.2013.01.006","article-title":"Obstructive sleep apnea and increased risk of glaucoma: a population-based matched-cohort study","volume":"120","author":"Lin","year":"2013","journal-title":"Ophthalmology"},{"key":"key-10.1136\/bjophthalmol-2016-308710-34","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1001\/archophthalmol.2010.220","article-title":"Frequent loss of nyctohemeral rhythm of intraocular pressure restored by nCPAP treatment in patients with severe apnea","volume":"128","author":"P\u00e9pin","year":"2010","journal-title":"Arch Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-35","first-page":"4660","article-title":"Impact of obstructive sleep apnea on sleep-wake stage ratio","volume":"2012","author":"Ng","year":"2012","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"key-10.1136\/bjophthalmol-2016-308710-36","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1167\/iovs.09-3668","article-title":"Twenty-four hour (Nyctohemeral) rhythm of intraocular pressure and ocular perfusion pressure in normal-tension glaucoma","volume":"51","author":"Renard","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"key-10.1136\/bjophthalmol-2016-308710-37","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1111\/j.1442-9071.2012.02768.x","article-title":"Glaucoma and obstructive sleep apnoea syndrome","volume":"40","author":"Faridi","year":"2012","journal-title":"Clin Experiment Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-38","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/S0161-6420(95)31053-6","article-title":"Ambulatory blood pressure monitoring in glaucoma. The nocturnal dip","volume":"102","author":"Graham","year":"1995","journal-title":"Ophthalmology"},{"key":"key-10.1136\/bjophthalmol-2016-308710-39","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1023\/A:1006113109864","article-title":"Ambulatory blood pressure monitoring in glaucoma patients. The nocturnal systolic dip and its relationship with disease progression","volume":"22","author":"Collignon","year":"1998","journal-title":"Int Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-40","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1177\/112067219600600309","article-title":"Simultaneous 24-hour monitoring of intraocular pressure and arterial blood pressure in patients with progressive and non-progressive primary open-angle glaucoma","volume":"6","author":"Detry","year":"1996","journal-title":"Eur J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-41","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1007\/s10384-003-0071-6","article-title":"Association between nocturnal blood pressure reduction and progression of visual field defect in patients with primary open-angle glaucoma or normal-tension glaucoma","volume":"48","author":"Tokunaga","year":"2004","journal-title":"Jpn J Ophthalmol"},{"key":"key-10.1136\/bjophthalmol-2016-308710-42","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1001\/archophthalmol.2012.2280","article-title":"Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma","volume":"130","author":"Mansouri","year":"2012","journal-title":"Arch Ophthalmol"}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjophthalmol-2016-308710","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T08:53:03Z","timestamp":1601110383000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjophthalmol-2016-308710"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,7]]},"references-count":42,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2017,9,26]]},"published-print":{"date-parts":[[2017,10]]}},"alternative-id":["10.1136\/bjophthalmol-2016-308710"],"URL":"https:\/\/doi.org\/10.1136\/bjophthalmol-2016-308710","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,7]]}}}