{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T13:24:37Z","timestamp":1788269077559,"version":"build-2803163510"},"reference-count":34,"publisher":"BMJ","issue":"1","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:sec><jats:title>Aim<\/jats:title><jats:p>To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Consecutive patients with grade II\u2013III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikger\u00e4te, Wetzlar, Germany) and Corvis (Oculus Optikger\u00e4te). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity \u226580% for each parameter of Corvis and final D value of Belin\/Ambrosio Enhanced Ectasia Display (BAD) were compared.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p\u22650.162) and DA ratio 2 (p\u22650.208).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam.<\/jats:p><\/jats:sec>","DOI":"10.1136\/bjophthalmol-2017-310355","type":"journal-article","created":{"date-parts":[[2017,5,31]],"date-time":"2017-05-31T00:40:23Z","timestamp":1496191223000},"page":"42-47","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":63,"title":["Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus"],"prefix":"10.1136","volume":"102","author":[{"given":"Tommy CY","family":"Chan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu Meng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vishal","family":"Jhanji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2017,5,30]]},"reference":[{"key":"2020050712593752000_102.1.42.1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2010.185868"},{"key":"2020050712593752000_102.1.42.2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2014-305120"},{"key":"2020050712593752000_102.1.42.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.02.020"},{"key":"2020050712593752000_102.1.42.4","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1016\/j.jcrs.2013.03.023","article-title":"Posterior corneal elevation and back difference corneal elevation in diagnosing forme fruste keratoconus in the fellow eyes of unilateral keratoconus patients","volume":"39","author":"Muftuoglu","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"2020050712593752000_102.1.42.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.11.012"},{"key":"2020050712593752000_102.1.42.6","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/j.ajo.2015.01.014","article-title":"Staging of keratoconus indices regarding tomography, topography, and biomechanical measurements","volume":"159","author":"Goebels","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"2020050712593752000_102.1.42.7","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20110721-01"},{"key":"2020050712593752000_102.1.42.8","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s40662-016-0038-6","article-title":"Assessing progression of keratoconus: novel tomographic determinants","volume":"3","author":"Duncan","year":"2016","journal-title":"Eye Vis"},{"key":"2020050712593752000_102.1.42.9","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2013-304494"},{"key":"2020050712593752000_102.1.42.10","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-1253"},{"key":"2020050712593752000_102.1.42.11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.044"},{"key":"2020050712593752000_102.1.42.12","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000628"},{"key":"2020050712593752000_102.1.42.13","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13715"},{"key":"2020050712593752000_102.1.42.14","doi-asserted-by":"crossref","first-page":"550","DOI":"10.3928\/1081597X-20160524-01","article-title":"Influence of pachymetry and intraocular pressure on Dynamic Corneal Response Parameters in healthy patients","volume":"32","author":"Vinciguerra","year":"2016","journal-title":"J Refract Surg"},{"key":"2020050712593752000_102.1.42.15","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.ajo.2014.03.018","article-title":"Pentacam Scheimpflug tomography findings in topographically normal patients and subclinical keratoconus cases","volume":"158","author":"Ruise\u00f1or V\u00e1zquez","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"2020050712593752000_102.1.42.16","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.ajo.2013.08.014","article-title":"Corneal topographic and tomographic analysis of fellow eyes in unilateral keratoconus patients using Pentacam","volume":"157","author":"Bae","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"2020050712593752000_102.1.42.17","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.jcrs.2014.05.052","article-title":"Comparison of multimetric D index with keratometric, pachymetric, and posterior elevation parameters in diagnosing subclinical keratoconus in fellow eyes of asymmetric keratoconus patients","volume":"41","author":"Muftuoglu","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"2020050712593752000_102.1.42.18","first-page":"121","article-title":"Collagen fibril orientation in the human corneal stroma and its implication in keratoconus","volume":"38","author":"Daxer","year":"1997","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2020050712593752000_102.1.42.19","doi-asserted-by":"publisher","DOI":"10.1007\/BF00918483"},{"key":"2020050712593752000_102.1.42.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.04.067"},{"key":"2020050712593752000_102.1.42.21","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2010.188300"},{"key":"2020050712593752000_102.1.42.22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.09.023"},{"key":"2020050712593752000_102.1.42.23","doi-asserted-by":"crossref","first-page":"785","DOI":"10.3928\/1081597X-20140930-01","article-title":"Assessment of ocular biomechanics using dynamic ultra high-speed Scheimpflug imaging in keratoconic and normal eyes","volume":"30","author":"Tian","year":"2014","journal-title":"J Refract Surg"},{"key":"2020050712593752000_102.1.42.24","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140513-02"},{"key":"2020050712593752000_102.1.42.25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2014\/147516","article-title":"Corneal biomechanical assessment using corneal visualization scheimpflug technology in keratoconic and normal eyes","volume":"2014","author":"Tian","year":"2014","journal-title":"J Ophthalmol"},{"key":"2020050712593752000_102.1.42.26","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.jbiomech.2015.12.031","article-title":"Detection of subclinical keratoconus through non-contact tonometry and the use of discriminant biomechanical functions","volume":"49","author":"Pe\u00f1a-Garc\u00eda","year":"2016","journal-title":"J Biomech"},{"key":"2020050712593752000_102.1.42.27","doi-asserted-by":"crossref","first-page":"1404","DOI":"10.1097\/ICO.0000000000000598","article-title":"Screening for Keratoconus With New Dynamic Biomechanical In Vivo Scheimpflug Analyses","volume":"34","author":"Steinberg","year":"2015","journal-title":"Cornea"},{"key":"2020050712593752000_102.1.42.28","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-11563"},{"key":"2020050712593752000_102.1.42.29","doi-asserted-by":"crossref","first-page":"468","DOI":"10.3928\/1081597X-20140521-01","article-title":"Ocular biomechanical metrics by CorVis ST in healthy brazilian patients","volume":"30","author":"Valbon","year":"2014","journal-title":"J Refract Surg"},{"key":"2020050712593752000_102.1.42.30","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.ajo.2013.12.024","article-title":"Corneal biomechanics as a function of intraocular pressure and pachymetry by dynamic infrared signal and scheimpflug imaging analysis in normal eyes","volume":"157","author":"Huseynova","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"2020050712593752000_102.1.42.31","doi-asserted-by":"crossref","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","article-title":"Detection of Keratoconus with a New Biomechanical Index","volume":"32","author":"Vinciguerra","year":"2016","journal-title":"J Refract Surg"},{"key":"2020050712593752000_102.1.42.32","doi-asserted-by":"crossref","first-page":"760","DOI":"10.3928\/1081597X-20160728-02","article-title":"Double-Pass Retina Point Imaging for the evaluation of Optical Light Scatter, retinal image Quality, and staging of Keratoconus","volume":"32","author":"Leonard","year":"2016","journal-title":"J Refract Surg"},{"key":"2020050712593752000_102.1.42.33","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-4960"},{"key":"2020050712593752000_102.1.42.34","first-page":"334","article-title":"Predictive analysis between Topographic, Pachymetric and Wavefront Parameters in Keratoconus, Suspects and normal eyes: creating Unified Equations to evaluate Keratoconus","volume":"41","author":"Prakash","year":"2016","journal-title":"Curr Eye Res"}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjophthalmol-2017-310355","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T08:55:12Z","timestamp":1601110512000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjophthalmol-2017-310355"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,30]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,12,15]]},"published-print":{"date-parts":[[2018,1]]}},"alternative-id":["10.1136\/bjophthalmol-2017-310355"],"URL":"https:\/\/doi.org\/10.1136\/bjophthalmol-2017-310355","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,30]]}}}