{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T09:53:35Z","timestamp":1758707615508},"reference-count":20,"publisher":"BMJ","issue":"3","funder":[{"name":"Ophtec BV Groningen, Netherlands"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>To evaluate the postoperative outcomes after implantation of a hydrophilic toric intraocular lens (tIOL) with a transitional conic toric surface in patients with astigmatism undergoing refractive lens exchange (RLE) or cataract surgery.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>In this monocentric study, clinical outcomes following implantation of the hydrophilic Precizon toric IOL model 565 (Ophtec) were analysed. For intraoperative axis alignment, the Verion Image Guided System was used. Intended versus achieved refraction, IOL position, visual acuity outcomes and power vector analyses were evaluated 3 months postoperatively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Forty-three eyes of 28 patients (40 eyes cataract, 3 eyes RLE) received a Precizon toric IOL with a cylindrical power between 1.0 and 7.5 D. Target refraction was emmetropia except for four eyes that had a myopic target. The median postoperative IOL rotation at slit lamp was 3\u00b0 with a range from 0\u00b0 to 16\u00b0. Uncorrected distance visual acuity (UDVA) increased from median 0.5 logMAR preoperatively to median 0.06 logMAR at 3 months postoperatively. Corrected distance visual acuity increased from 0.20 to \u22120.02 logMAR. Median preoperative subjective cylinder was 1.5 D and 3 months postoperatively 0.25 D.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Preoperative diagnostics, IOL selection and correct intraoperative positioning of tIOLs are essential for good outcomes and postoperative spectacle independence following cataract or RLE surgery. Visual acuities and rotational stability of the Precizon toric IOL showed very good outcomes and the subjective postoperative astigmatism could be reduced significantly.<\/jats:p><\/jats:sec>","DOI":"10.1136\/bjophthalmol-2017-310386","type":"journal-article","created":{"date-parts":[[2017,8,4]],"date-time":"2017-08-04T00:40:26Z","timestamp":1501807226000},"page":"313-316","update-policy":"http:\/\/dx.doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":21,"title":["Clinical outcomes after implantation of a toric intraocular lens with a transitional conic toric surface"],"prefix":"10.1136","volume":"102","author":[{"given":"Bettina C","family":"Thomas","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ramin","family":"Khoramnia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerd U","family":"Auffarth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mike P","family":"Holzer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2017,8,3]]},"reference":[{"key":"2020050713004507000_102.3.313.1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2013-304228"},{"key":"2020050713004507000_102.3.313.2","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1016\/j.jcrs.2007.10.024","article-title":"Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens results","volume":"34","author":"Hill","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"2020050713004507000_102.3.313.3","unstructured":"Michelitsch M , Ardjomand N , Vidic B , et al . Prevalence and age-related changes of corneal astigmatism in patients before cataract surgery]. Ophthalmologe 2016 (Epub ahead of print)."},{"key":"2020050713004507000_102.3.313.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.09.027"},{"key":"2020050713004507000_102.3.313.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.08.060"},{"key":"2020050713004507000_102.3.313.6","doi-asserted-by":"crossref","first-page":"162","DOI":"10.4103\/2008-322X.183924","article-title":"Three methods for correction of a stigmatism during phacoemulsification","volume":"11","author":"Mohammad-Rabei","year":"2016","journal-title":"J Ophthalmic Vis Res"},{"key":"2020050713004507000_102.3.313.7","doi-asserted-by":"crossref","first-page":"152","DOI":"10.3928\/1081597X-20160204-01","article-title":"Stability of keratometric astigmatism after\u00a0non-penetrating femtosecond laser intrastromal astigmatic keratotomy performed during\u00a0laser cataract surgery","volume":"32","author":"Day","year":"2016","journal-title":"J Refract Surg"},{"key":"2020050713004507000_102.3.313.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.04.010"},{"key":"2020050713004507000_102.3.313.9","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e32835ac853"},{"key":"2020050713004507000_102.3.313.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2015.10.002"},{"key":"2020050713004507000_102.3.313.11","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/1471-2415-12-41","article-title":"Visual acuity improvements after implantation of toric intraocular lenses in cataract patients with astigmatism: a systematic review","volume":"12","author":"Agresta","year":"2012","journal-title":"BMC Ophthalmol"},{"key":"2020050713004507000_102.3.313.12","first-page":"867","article-title":"Postoperative results after implantation of a toric, aspheric intraocular lens","volume":"232","author":"Khoramnia","year":"2015","journal-title":"Klin Monbl Augenheilkd"},{"key":"2020050713004507000_102.3.313.13","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-007-1659-x"},{"key":"2020050713004507000_102.3.313.14","doi-asserted-by":"crossref","first-page":"187","DOI":"10.3928\/1081597X-20130212-01","article-title":"Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatism","volume":"29","author":"Thomas","year":"2013","journal-title":"J Refract Surg"},{"key":"2020050713004507000_102.3.313.15","unstructured":"Ophtec BV . Precizon transitional conic toric IOL, product information brochure, L125-207-5, 2015."},{"key":"2020050713004507000_102.3.313.16","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00797-5"},{"key":"2020050713004507000_102.3.313.17","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1111\/j.1442-9071.2009.02154.x","article-title":"Comparison of the AcrySof SA60 spherical intraocular lens and the AcrySof Toric SN60T3 intraocular lens outcomes in patients with low amounts of corneal astigmatism","volume":"37","author":"Statham","year":"2009","journal-title":"Clin Exp Ophthalmol"},{"key":"2020050713004507000_102.3.313.18","doi-asserted-by":"crossref","first-page":"452","DOI":"10.3928\/1081597X-20160428-07","article-title":"Clinical outcomes after cataract surgery with a new transitional toric intraocular lens","volume":"32","author":"Ferreira","year":"2016","journal-title":"J Refract Surg"},{"key":"2020050713004507000_102.3.313.19","doi-asserted-by":"crossref","first-page":"151","DOI":"10.2147\/OPTH.S91298","article-title":"Astigmatism management in cataract surgery with Precizon(\u00ae) toric intraocular lens: a prospective study","volume":"10","author":"Vale","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"2020050713004507000_102.3.313.20","doi-asserted-by":"crossref","first-page":"2274","DOI":"10.1016\/j.jcrs.2015.10.059","article-title":"Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system: influence of pupil size, decentration, and rotation","volume":"41","author":"Kim","year":"2015","journal-title":"J Cataract Refract Surg"}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjophthalmol-2017-310386","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T08:55:15Z","timestamp":1601110515000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjophthalmol-2017-310386"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,3]]},"references-count":20,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2018,2,23]]},"published-print":{"date-parts":[[2018,3]]}},"alternative-id":["10.1136\/bjophthalmol-2017-310386"],"URL":"https:\/\/doi.org\/10.1136\/bjophthalmol-2017-310386","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,8,3]]}}}